HomeMy WebLinkAboutPermit Correspondence 2005-8-11 (2) 525 NW Second Street, Corvallis, Oregon 97330 If 800-383.8855 ph 541.758. 1302 fx 54 L753.2264 www.claircompanv.com August 11,2005 City of Springfield Development Services Department 225 Fifth Street Springfield, OR 97477 Attention: Dave Puent, Building Official Subject: Project: Project No: Building Permit No.: 1st Plan Review - Conditions of Approval OML Remodel RiverBend Annex - PeaceHealth 1141-009 COM2005-00836 Clair Company, Inc. (CLAIR) has partially completed the 1st Plan Review for the OML Remodel RiverBend Annex- PeaceHealth construction documents on behalf of the City of Springfield (City). CLAIR recommends permit issuance with conditions of approval, which includes the comments provided in the attached plan review document. Please note that additional plan review comments may be added at the completion of the plan review. During a recent site walk and meeting with the owner and design team, it was detennined that because all disciplines construction have already begun work, CLAIR would recommend penn it issuance even though significant code concerns exist as documented in the attached plan review document. It is our understanding that the design professional of record will be submitting an Alternate Materials and Methods request regarding the required "Control Area" for the OML lab facility. This will also need to provide clarifications regarding the proposed use and occupancy of the areas adjacent to the Control Area, proposed chemical quantities for the lab and intended use of existing Group H occupancies in the building. CLAIR requests that the permit applicant/designer respond in writing to each Condition of Approval comment in the plan review document by adding an applicant response row directly below the CLAIR review comment field and fill in the indicated fields on the attached MS EXCEL document along with all necessary requested supporting documentation. If you have any questions or need clarification regarding the infonnation provided or requested, please do not hesitate to contact me at (541) 758-1302 or by email ataclair(@claircomoanv.com.. Respectfully Submitted, Allan Clair, C.B.O. Project Manager Cc: Al Gerard, City of Springfield Fire Department David Morey, SRG CLAIR Project File # 1141-007 Attached: # 1 - Codes and Standards #2 - Submittal Log #3 - Plan Review Document City of Springfield - OML Remodel RiverBend Annex - PeaceHealth 1 sl Plan Review - Condition of Approval August 11,2005 Page 20f2 ATTACHMENT#l-CODESANDSTANDARDS State of Oregon 2004 edition Oregon Structural Specialty Code (OSSC) State of Oregon 2004 edition Oregon Mechanical Specialty Code (OMSC) State of Oregon 2000 edition Oregon Plumbing Specialty Code (OPSC) State of Oregon' 2002 edition Oregon Electrical Specialty Code (OESC) A TT ACHMENT #2 ~ SUBMITTAL LOG Our plan review comments are based on the following submitted construction documents: 7/7/2005 6/29/2005 City of Springfield 1000 Waiting Building permit for PeaceHealth/OML Remodel Riverbend Annex, valuation $8,200,000, 7/7/2005 City of Springfield 1001 Waiting COS Special Inspection and Testing Forni- stating that no special inspections anticipated. 7/7/2005 City of Springfield 1002 Waiting Lighting forms - uristamped/unsigned. 7/7/2005 615/2005 City of Springfield 1003 2 Waiting Structural calculations pages 1 through 15 to verify structural adequacy ofT! remodel work. 7/7/2005 6/1712005 City of Springfield 1004 6 8/1l/05 (2 sets) Specifications - signed and stamped. 7/7/2005 6!l7/2005 City of Springfield 1005 6 8/1l/05 (2 sets) Drawings including Architectural, Lab Planning, {' Structural, Plumbing, Mechanical, and Electrical. c City of Springfield SRG OML Remodel RiverBend - Peace Health - Plan Review Occupancy Group(s): Type of Construction: Stories: B, A-2, A-3, S-2, H-3 liB 2 33' - 8" Height (feet): Building Area (sq ft): 1331,546SQ ft Occupant Load: 598 persons Building Permit: COM2005-00836 Sprinklers: Yes ,Alarms: Yes Fire Walls No Please respond in writing to each comment by creating a response row to each item. This plan review document is created in Microsoft EXCELOO. Each city comment is a whole number. Your response to each item will be a x.1 number. For example, City comment is Item 1.0, your response is Item 1.1. Each of your responses will be shown in bold face type. Indicate which detail, specification, or calculation shows the requested information. An explanation of how compliance with the code requirement is achieved and a reflection of that explanation in the construction document with the revisions clouded is our expectation. Your complete and clear response will expedite the re-review and approval of the referenced project document or deferred submittal. Thank you for your assistance. Item # Construction Document or Plan Sheet and . COate' BUILDING - NON-ST WCTURAL PLAN REVIEW Plan Sheet # A- 104. Dated 6/17/05 Comment From Comment Date CLAIR 8/11/2005 2 Plan Sheet # A- 104. Dated 6/17/05 CLAIR 8/11/2005 3 Plan Sheets # A- 121, A-411&A- 511. Dated 6/17/05 CLAIR 8/11/2005 For questions, please call CLAIR at (541) 758-1302 City Comment / Applicant Response Control areas shall be separated from each other by walls of not less than 1-hour fire barrier. Please provide clear location of the control area boundaries. OSSC 414. The floor construction of the control area, and the construction supporting the floor of the control area, shall have a minimum 2- hour fire resistance rating. There are no exceptions to reduce to 1- hour fire rating. Please provide the appropriate rating. OSSC 414.2.3. It is our understanding per discussions with SRG on August 9, 2005 that SRG will pursue an AM&M to meet the intent of the essc for the 2 hour requirement. Shafts are required to protect openings and penetrations through, floor/ceiling assemblies. Please provide complete information (first and second floor) on dumbwaiter located on gridlines 19/P. essc 414.2.1. Page: 1 of 12 Response From Response Date Status Condition of Approval Condition of Approval Condition of Approval 1st Plan Review - August 11, 2005 CLAIR Project No.: 1141-009 City of Springfield SRG Item # 4 5 6 7 8 Comment From CLAIR CLAIR CLAIR CLAIR CLAIR OML Remodel RiverBend - PeaceHealth - Plan Review Comment Date 8/11/2005_ 8/11/2005 8/11/2005 8/11/2005 8/11/2005 Construction Document or Plan Sheet and (Datta\, ___ U-.lIII_ Plan Sheet # A- 103. Dated 6/17/05 Plan Sheet # A- 121. Dated 6/17/05 Plan Sheet # A- 121. Dated 6/17/05 Plan Sheet # A- 121. Dated 6/17/05 General For questions, please call CLAIR at (541) 758-1302 City Comment I Applicant Response One-hour fire rated shaft shall have 1-hour fire rated'protection. The Dumbwaiter located on gridlines 19/P shows a 1-hour fire rated wall. Please confirm compliance of the access doors on sheet # A-411. OSSC 707.4'. Incidental use areas are not required to be separated if sprinklered system is in place, but shall be separated by construction capable of resisting the passage of smoke. Doors shall be self-or automatic closing upon detection of smoke. Please confirm that Storage Room # 201; Clean/ Dirty Lab Coats # 217; Slide Storage #206; Clean/ Dirty Lab Coats # 273 are compliant per OSSC 302.1.1.1. Exits shall not be used for any purpose that interferes with its function as a means of egress. Confirm that the south path of egress through break areas # 255 & 268 to Stairs # 1 and # 2 are clear and unobstructed. OSSC 1013.2 & 1017.1. Accessory assembly areas are not considered separatE: occupancies if the floor area is equal to or less than 750 sqft. Conference Room # 266 is 980 sqft; therefore, is an A-3 occupancy. Doors serving an occupant load of 50 persons need to swing in direction of travel. The occupant load of the Conference room is 66 persons. Please modify the occupancy group and door # 266B needs to swing in direction of travel. OSSC 1008.1.2. Every project for alteration of an existing building shall be made to insure that, to the maximum extend feasible, the paths of travel to the altered area, the restrooms, telephones and drinking fountains serving the altered area are readily accessible. In choosing which accessible elements to provide, priorities shall be as follow: (1;- Parking; (2) Accessible entrance; (3) Accessible route to altered area; (4) Accessible restrooms; (5) Accessible telephones; (5;- Accessible drinking fountains (6) When possible additional accessible elements. Please'provide information on which of these elements will be part of the architectural barrier removal improvement plan. OSSC 1113.1.1. Page:' 2 of 12 Building Permit: COM2005-00836 Response From Response Date Status Condition of Approval Condition of Approval Condition of Approval Condition of Approval Condition of Approval 1 st Plan Review - August 11, 2005 CLAIR Project No.: 1141-009 City of Springfield SRG Item # 9 10 11 12 13 14 15 Comment From CLAIR CLAIR CLAIR CLAIR CLAIR CLAIR CLAIR Comment Date 8/11/2005 8/11/2005 8/11/2005 8/11/2005 . 8/11/2005 8/11/2005 8/11/2005 OM L Remodel RiverBend - Peace Health .:. Plan Review Construction Document or Plan Sheet and fDat,~\ . Plan Sheet # A- Please provide information for accessible parking spaces and.. confirm that the accessible route is continuous from public streets, 1~~1~~~d sidewalks and public transportation per OSSC 1103.2.4. Plan Sheet # A- 103. Dated 6/17/05 Plan Sheet # A- 121. Dated 6/17/05 Plan Sheet # A- 104. Dated 6/17/05 Plan Sheet # A- 104. Dated 6/17/05 Plan Sheet # A- 121. Dated 6/17/05 Plan Sheet # EL121. Dated 6/17/05 For questions, please call CLAIR at (541) 758-1302 <?ity Comment / Applicant Response The primary area of work is the second floor but the exiting is. through the first floor. Please provide evidences that the first floor . is compliant with the exiting and accessibility requirements for per OSSC 1021. 1109.3.1. Please provide documentation, that the exit stairs at north and south side are compliant with accessibility requirements per OSSC 1009 and 1109.8. On Sheet A-104 "Code Summary (Section 715) stair enclosures are not mentioned. Please confirm 1-hour rating at existing doors located on Stairs # 1 and # 2. OSSC Table 715.3. All passenger elevators that are on an accessible route are required to be accessible. Confirm that existing elevator located on gridlines 26/S is compliant with accessible requirements. OSSC 1108.1.1.3, 1108.3.1.1, ADAAG Figures 20 & 23. Please clarify accessibility compliance at public phones located at Corridor # 272 and Phone Alcove 253A. OSSC 1108.4.2, 1109.10.13 Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel and in cases where the exit or path of egress travel is not immediately visible to the occupants. Exit signs placement shall be such that no point in an exit access corridor is more. than 100 ft or the listed viewing distance for the sign, which ever is less, from the nearest visible exit sign. Please provide exit signs in the following locations: Corridor # 259 door # 268a; Corridor # 242 a directional exit sign towards stair # 2; Corridor # 279 a directional exit sign towards corridors 242 and # 212; Corridor # 251 a directional exit sign towards Stair # 1. OSSC 1011.1. " Page: 3 of 12 Building Permit: COM2005-00836 Response From Response Date, Status Condition of Approval Condition of Approval Condition of Approval Condition of Approval Condition of Approval Condition of Approval Condition of Approval 1 st Plan Review - August 11, 2005 CLAIR Project No.: 1141-009 City of Springfield SRG OML Remodel RiverBend - Peace Health - Plan Review Building Permit: COM2005-00836 For questions, please call CLAIR at (541) 758-1302 Page: 4 of 12 1st Plan Review - August 11, 2005 CLAIR Project No.: 1141-009 City of Springfield . SRG Item # Comment From 25 CLAIR 26 CLAIR 27 . CLAIR 28 CLAIR 29 CLAIR 30 CLAIR 31 CLAIR 32 CLAIR 33 CLAIR 34 CLAIR " OML Remodel RiverBend - PeaceHealth - Plan Review Comment Date 8/11/2005 8/11/2005 8/11/2005 8/11/2005 8/11/2005 8/11/2005 8/11/2005 8/11/2005 8/11/2005 8/11/2005 Construction Document or Plan Sheet and lDate) Plan Sheet # A- 531. Dated 6/17/05 Plan Sheet # A- 531. Dated 6/17/05 General Plan Sheet # A- 401. Dated 6/17/05 Plan Sheet # A- 121. Dated 6/17/05 Plan Sheet # A- 121. Dated 6/17/05 Plan Sheet # A- , 103. Dated 6/17/05 Plan Sheet # A- 103. Dated 6/17/05 Plan Sheet # A- 104. Dated 6/17/05 General: Ventilation Systems For questions, please call CLAIR at (541) 758-1302 City Comment I Applicant Response Please confirm that glazing at existing roll-up door (Type E7) on 2- hour fire rated wall is 1 1/2-hour fire rated and is safety glass. OSSC 2406.3. Please confirm that all existing doors that have glazing panels within 24" of doors have safety glass. Example: Door Type E8. OSSC 2406.3. NFPA 704 hazard warning signs required at entrances to locations where hazardous materials are store, used or handled. Please provide information for review. OFC 270304. Confirm that Men # 270 & # 248 comply with accessibility requirements. OSSC 1109.10. On any floor where water fountains or coolers are installed, at least 50%, but in no case less than one, shall be accessible, and at least one fountain or cooler shall be mounted ata standard, height. Please provide. OSSC 1108.4.1. Dressing rooms shall have a clear floor space allowing a person in a wheelchair to make a 180 degree turn and shall have a bench installed adjacent to the longest wall in the rqom. The bench shall be at least 24" wide and 48" long, and shall be mounted not less than 17" or more than 19" above the finished floor. Clear floor space shall be provided adjacent to the bench to allow for parallel transfer. Please provide. OSSC 1109.23.1.1, 1109.23.1.2, 1109.23.1.3. Provide occupancy classification for the three H occupancies in Sector G1. OSSC 302.1 Provide panic hardware on exit doors from H occupancies in Sector G1. OSSC 1008.1.9 Provide t1azardous Materials Management Plan and Hazardous Materials Inventory Statement with materials classified in accordance with the Oregon Fire Code. Include an aggregate quantity per hazard category. OFC 2701.5.1 amd 2701.5.2 Provide HVAC balancing documentation. 403.3.4 OMSC Page: 5 of 12 Building Permit: COM2005-00836 Response From Response Date Status Condition of Approval Condition of Approval Condition of Approval Condition of Approval Condition of Approval Condition of Approval Condition of Approval Condition of Approval Condition of Approval Condition of Approval 1 st Plan Review - August 11, 2005 CLAI R Project No.: 1141-009 City of Springfield SRG Item # Comment From Comment Date ELECTRICAL PLAN ~EVIEW 35 36 37 38 39 40 41 42 CLAIR CLAIR CLAIR CLAIR CLAIR CLAIR CLAIR CLAIR . 8/11/2005 8/11/2005 8/11/2005 8/11/2005 8/11/2005 8/11/2005 8/11/2005 8/11/2005 OML Remodel RiverBend - PeaceHealth - Plan Review Construction Document or Plan Sheet and fDate\ Plans dated 06/17/05 All electrical sheets. General Rule Reference General Code Reference Plans dated 06/17/05 All electrical sheets. Plans dated 06/17/05 All electrical sheets. Plans dated 06/17/05 All electrical sheets. Plans dated 06/17/05 All electrical sheets. Plans dated 06/17/05 All electrical sheets. For questions, please call CLAIR at (541) 758-1302 City Comment / Applicant Response We are unable to provide an accurate electical fiXture count in order to calculate required electrical permittimg fees due to a lack of clear information concerning the number of electrical panels and branch circuits involved in the remodel. Electrical work is progressing and permits need to be issued as soon as possible. Please orovide necessary information. "The plans shall ... be of sufficient clarity to indicate the location, nature and extent of the work proposed and show in detail that it will conform to the applicable electrical code requirements, laws, ordinances, rules and regulations; OAR 918-311-0040 (Standards for Electrical Plan Submissions) "Review and approval by the authority having jurisdiction shall not relieve the applicant of the responsibility of compliance with this Code." OESC Art. 80.21 (C) (Concerning Electrical Plans Review). There appears to be insufficient information to determine if the load calculations are appropriate, complete, and accurate per: OAR 918 271-0040, OAR 918-311-0050 (Standards for Electrical Plans Review) & (OESC Art. 220 & Art. 80.21 (B)), We are unable to determine if the equipment is suitable for the environment per: OAR 918-271-0040, OAR 918-311-0050 (Standards for Electrical Plans Review) & (OESC Art. 110.02 & Art. 80.21 (B)). The size and rating of all equipment cannot be clearly ascertained per: OAR 918-271-0040, OAR 918-311-0050 (Standards for Electrical Plans Review) & (OESC Art. 110.02 & Art. 80.21 (B)). We cannot confirm if the feeder wiring method including size, placement, protection and termination are in conformance to the Oregon Electrical Specialty Code. OAR 918-271~0040, OAR 918- 311-0050 (Standards for Electrical Plans Review) & (OESC Art. 215,230 & Art. 80.21 (B)). We are unable to verify conduit and box fill per: OAR 918-271- 0040, OAR 918-311-0050 (Standards for Electrical Plans Review) & (OESC Art. 314.16, chapter nine tables & Art. 80.21 (B)). Page: 6 of 12 Building Permit: COM2005-00836 Response From Response Date Status Condition of Approval Condition of Approval Condition of Approval Condition of Approval Condition of Approval Condition of Approval Condition of Approval Condition of Approval 1 st Plan Review - August 11, 2005 CLAIR Project No.: 1141-009 City of Springfield SRG OML Remodel RiverBend - PeaceHealth - Plan Review Building Permit: COM2005-00836 Construction Item # Comment From Comment Document or City Comment I Applicant Response Response Response Status Date Plan Sheet and From Date (Date) Plans dated We are unable, to completely verify conductor size, ampacity, 43 CLAIR 8/11/2005 06/17/05 All placement, protection and termination. per: OAR 918-271-0040, electrical sh13ets. OAR '918-311-0050 (Standards for Electrical Plans Review) & Condition of (OESC Art. 210.19 & Art. 80.21 (B)). . Approval Plans dated Information seems to be missing concerning equipment working 44 CLAIR 8/11/2005 06/17/05 All clearances per: OAR 918-271-0040, OAR 918-311-0050 ' electrical sheets. (Standards for Electrical Plans Review) & (OESC Art. 110. 26 & Condition of Art. 80.21 (B)). Approval Plans dated Equipment location, size, placement, protection and termination 45 CLAIR 8/11/2005 06/17/05 All apparently cannot be completely verified per: OAR 918-271-0040" electrical sheets. OAR 918-311-0050 (Standards for Electrical Plans Review) & Condition of (OESC Art. 110.11 & Art. 80.21 (B)). Approval Plans dated Equipment accessibility apparently cannot be determined per: OAR 46 CLAIR 8/11/2005 06/17/05 All 918-271-0040, OAR 918-311-0050 (Standards for Electrical Plans electrical sheets. Review) & (OESC Art. 110.26 & Art. 80.21 (B)). Condition of Approval Plans dated It is not completely clear as to which electrical panels are staying, 47 CLAIR 8/11/2005 06/17/05 All which are being removed, and which are being modified. Please Condition of electrical sheets. clarify. See General Electrical Note #1 Approval Plans dated We arer unable to determine if the equipment intended to interrupt 06/17/05 sheets current at fault levels has the interrupting rating sufficient for the 48 CLAIR 8/11/2005 E601 through nominal circuit voltage and the current" that is available at the line terminals of the equipment. Please clarify. OESC 11 0.9 Condition of E604 Approval Plans dated The panel schedule appears to be missing for existing panel 49 CLAIR 8/11/2005 06/17/05 sheets #41 J 15 located on sheet EP-111. OAR 918-311-0040 (Standards E606 through for Electrical Plan Submissions) Condition of E609 Approval Plans dated The panel schedule appears to be missing for existing panel 50 'CLAIR 8/11/2005 06/17/05 sheets #21M22A located on sheet EP-111. OAR 918-311-0040 (Standards E606 through for Electrical Plan Submissions) Condition of E609 . Approval Plans dated The panel schedule appears to be missing for existing panel 51 CLAIR 8/11/2005 06/17/05 sheets #41M22 located on sheet EP-111. OAR 918-311-0040 (Standards E606 through for Electrical Plan Submissions) Condition of E609 Approval For questions, please call CLAIR at (541) 758-1302 Page: 7 of 12 1 st Plan Review - August 11, 2005 CLAI R Project NO.: 1141-009 ' City of Springfield SRG OML Remodel RiverBend - PeaceHealth - Plan Review Building Permit: COM2005-00836 Construction Item # Comment From Comment Document or City Comment / Applicant Response Response Response Status Date Plan Sheet and From Date I~~'~\ Plans dated The panel schedule appears to be missing for existing panel 52 CLAIR 8/11/2005 06/17/05 sheets #41P22 located on sheet EP-111. OAR 918-311-0040 (Standards E606 through for Electrical Plan Submissions) Condition of E609 Approval Plans dated The panel schedule appears to be missing for existing panel 53 CLAIR 8/11/2005 06/17/05 sheets #E41P22 located on sheet EP-111. OAR 918-31:1-0040 (Standards E606 through for Electrical Plan Submissions) Condition of E609 Approval Plans dated The panel schedule appears to be missing for new panel #U4A 1 54 CLAIR 8/1112005 06/17/05 sheets located on sheet EP-111. OAR 918-311-0040 (Standards for E606 through Electrical Plan Submissions) Condition of E609 Approval Plans dated The panel schedule appears to be missing for new panel #U4A2' 55 CLAIR 8/11/2005 06/17/05 sheets located on sheet EP-111. OAR 918-311-0040 (Standards for E606 through Electrical Plan Submissions) Condition of E609 Approval Plans dated The panel schedule appears to be missing for new panel #U4A3 56 CLAIR 8/11/2005 06/17/05 sheets located on sheet EP-111. OAR 918-311-0040 (Standards for E606 through Electrical Plan Submissions) Condition of E609 Approval Plans dated The panel schedule appears to be missing for new panel #U4F19 57 CLAIR 8/11/2005 06/17/05 sheets located on sheet EP-111. OAR 918-311-0040 (Standards for E606 through Electrical Plan Submissions) Condition of E609 Approval Plans dated The panel schedule appears to be missing for new panel #21 K11 58 CLAIR 8/1112005 06/17/05 sheets located on sheet EP-111. OAR 918-311-0040 (Standards for E606 through Electrical Plan Submissions) Condition of E609 Approval Plans dated The panel schedule appears to be missing for new panel #41 K11 59 CLAIR 8/11/2005 06/17/05 sheets located on sheet EP-111. OAR 918-311-0040 (Standards for E606 through Electrical Plan Submissions) Condition of E609 Approval Plans dated The panel schedule appears to be missing for new panel #U2K11 60 CLAIR 8/11/2005 06/17/05 sheets located on sheet EP-111. OAR 918-311-0040 (Standards for E606 through Electrical Plan Submissions) Condition of E609 Approval For questions, please call CLAIR at (541) 758-1302 Page: 8 of 12 1st Plan Review - August 11, 2005 CLAIR Project No.: 1141-009 City of Springfield SRG OML Remodel RiverBe"nd . PeaceHealth . Plan Review Building Permit: COM2005-00836 Construction Item # Comment From Comment Document or City Comment / Applicant Response Response Response Status Date Plan Sheet and . From Date (()~'~I Plans dated The panel schedule appears to be missing for new panel #21 L27 61 CLAIR 8/11/2005 06/17/05 sheets located on sheet EP-111. OAR 918-311-0040 (Standards for E606through Electrical Plan Submissions) Condition of E609 Approval, Plans dated The panel schedule appears to be missing for new panel #41 L27 62 CLAIR 8/11/2005 06/17/05 sheets located on sheet EP-111. OAR 918-311-0040 (Standards for E606 through Electrical Plan Submissions) Condition of E609 Approval Plans dated The panel schedule appears to be missing for new panel #21 R12 63 CLAIR 8/11/2005 06/17/05 sheets located on sheet EP-111. OAR 918-311-0040 (Standards for E606 through Electrical Plan Submissions) Condition of E609 Approval Plans dated The panel schedule appears to be missing for new panel #21 R23 64 CLAIR 8/11/2005 06/17/05 sheets located on sheet EP-111. OAR 918-311-0040 (Standards for E606 through Electrical Plan Submissions) Condition of E609 Approval Plans dated The panel schedule appears to be missing for new panel #41R1,2 65 CLAIR 8/11/2005 06/17/05 sheets located on sheet EP-111. OAR 918-311-0040 (Standards for E606 through Electrical Plan Submissions) Condition of E609 Approval Plans dated The panel schedule appears to be missing for existing panel 66 CLAIR 8/11/2005 06/17/05 sheets #41M15 located on sheets EP-111 and LE-425. OAR 918-311- E606 through 0040 (Standards for Electrical Plan Submissions) Condition of E609 Approval Plans dated The panel schedule appears to be missing for new panel #L21J15B 67 CLAIR 8/11/2005 06/17/05 sheets located on sheets EP-111 and LE-425. OAR 918-311-0040 E606 through (Standards for Electrical Plan Submissions) Condition of E609 Approval Plans dated The panel schedule appears to be missing for new panel #L21J2A 68 CLAIR 8/11/2005 06/17/05 sheets located on sheets EP-111 and LE-425. OAR 918-311-0040 E606 through (Standards for Electrical Plan Submissions) Condition of E609 Approval Plans dated The panel schedule appears to be missing for new panel #L21J2B 69 CLAIR - 8/11/2005 06/17/05 sheets located on sheets EP-111 and LE-425. OAR 918-311-0040, E606 through (Standards for Electrical Plan Submissions) Condition of E609 Approval For questions, please call CLAIR at (541) 758-1302 Page: 9 of 12 1 st Plan Review - August 11, 2005 CLAIR Project No'.: 1141-009 City of Springfield SRG Item # 70 71 72 73 74 75 76, 77 Comment From CLAIR CLAIR CLAIR FIRE ALARM SYSTE ~ CLAIR CLAIR CLAIR CLAIR CLAIR , FIRE SPRINKLER SYSTEM Comment Date 8/11/2005 8/11/2005 8/11/2005 8/11/2005 8/11/2005 8/11/2005 8/11/2005 8/11/2005 OML Remodel RiverBend - PeaceHealth - Plan Review Construction Document or Plan Sheet and COate) Plans dated 06/17/05 sheets E606 through E609 Plans dated 06/17/05 All electrical sheets. City Comment I Applicant Response The panel schedule appears to be missing for new panel #L21J2C located on sheets EP-111 and LE-425. OAR 918-311-0040 (Standards for Electrical Plan Submissions) All transformers may need secondary side protection, (OESC Art. . 450.3). The feeder from the transformer to the panel may also need over-current protection, (OESC Art. 215.3, 240.4(F), & 240.21), and protection may be required for the panel board: (OESC Art. 408.16 (A) & (B)). Recommend field verification at time of installation for compliance to the above listed code articles. Lighting Energy Lighting energy budget is not complete. It is missing form 2a Budqet Sheet "Summary" sheet. General: Fire Alarm Systems Specification 16723 Dated 5/6/05 Section 1.5 Specification 16723 Dated 5/6/05 Section 2.1 Specification 16723 Dated 5/6/05 Section 1.3 Specification 16723 Dated 5/6/05 Section 3.2.B For questions, please call CLAIR at (541) 758-1302 CLAIR will review the fire alarm submittal (based on NFPA 72, 2002 Edition) upon receipt of working plans (shop drawings) provided that the submittal has' been' reviewed for design intent by the "Architect or Enqineer of Record". OSSC 106.3.4.2 NFPA 72, The National Fire Alarm Code shall be the 2002 Edition in accordance with the Springfield Fire Code. Acceptable manufacturers should be listed as those compatible with the existing system as specified in Section 1.1.C Components shall be listed for use with the Fire Alarm Control Panel. 4.4.2 NFPA 72, 2002 Edition. Provide complete information that includes information regarding the existing system and alterations, including specifications, shop drawings, battery calculations, and notification appliance circuit VOltage drop calculations shall be submitted for approval. Provide information on existing system to clearly document code compliance including compatibility with the existing system. 4.5.1 NFPA 72. 2002 Edition The 1993 edition of NFPA 72 was a consolidation of 6 NFPA standards and guides including NFPA 72H. The recommendations that were taken from NFPA 72H were changed to mandatory requirements. Page: 10 of 12 Building Permit: COM2005-00836 Response From Response Date Status Condition of Approval Note to Inspector Condition of Approval Condition of Approval Condition of Approval Condition of Approval Condition of Approval Note to Inspector 1 st Plan Review - August 11, 2005 CLAIR Project No.: 1141-009 City of Springfield SRG OML Remodel RiverBend - PeaceHealth - Plan Review Building Permit: COM2005-00836 Item # Comment Date Construction Document or Plan Sheet and mate) Comment From City Comment / Applicant Response Response From Status Response Date J CLAIR will review the Fire Sprinkler submittal (based on NFPA 13, 78 CLAIR 8/11/2005 qeneral: Fire 2002 Edition) upon receipt. of working plans, provided that the Sprinkler Systems submittal. has been reviewed for design intent by the "Architect or Condition of Enqineer of Record". OSSC 106.3.4.2 Approval Specifications NFPA 13, Installation of Sprinkler Systems shall be the 2002 79 CLAIR 8/11/2005 15300 Edition in accordance with the Springfield Fire Code. Dated 6/17/05 Condition of Section 1.1.C Approval General: Fire Provide working plans (shop drawings) showing items from the list 80. . CLAIR 8/11/2005 in Section 14.1.3 that pertain to the design of the system for this Condition of Sprinklers proiect. Section 14.1.3, NFPA 13. 2002 Edition. Approval PLUMBING PLAN REVIEW 81 Drawing P-101 6/17/05 CLAIR 8/11/2005 82 CLAIR 8/11/2005 Drawing P-414 6/17/05 83 CLAIR 8/11/2005 Drawing P-417 6/17/05 84 CLAIR 8/11/2005 Drawing P-418 6/17/05 85 CLAIR 8/11/2005 Drawing P-419 6/17/05 86 CLAIR 8/11/2005 Drawing LP-427 6/17/05 87 CLAIR 8/11/2005 Drawing LP-429 6/17/05 For questions, 'please call CLAIR at (541) 758-1302 Grid lines K/24, K/16, K/14, R/20 and P/12. In these areas where existing waste lines are capped and tied into new drain lines, the materials and installation of these connections shall be in accordance with the requirements of the OPSC. New drains and existing drflins shall be tested to the satisfaction of the Administrative Authority. Sections 304.0 and 310.4 of the OPSC. Condition of Approval On this Plan sheet keyed notes 3 and 4 along with line drawings indicate a scullery sink and dishwasher on the 2nd floor. Please provide information regarding the possibility of grease discharge into these devices. Section 714.1 of the OPSC. Condition of Approval Condition of Approval Condition of Approval . Condition of Approval Grid R/25 New tie-in points. See Clair comment # 2 Grid P/19 New tie-in points. See Clair comment # 2 Grid P/13 New tie-in points. See Clair comment # 2 The Mens restroom # 248 and Womens restroom # 245 require floor drains.Section 412.2.1 of the OPSC. Please provide information. The Mens restroom # 270 and Womens restroom # 265 require floor drains.Section 412.2.1 of the OPSC. Please provide. information. Condition of Approval Condition of Approval Page: 11 of 12 1st Plan Review - August 11, 2005 CLAIR Project No.: 1141-009 City of Springfield SRG Item # 88 Comment From CLAIR Comment Date. 8/11/2005 OM L Remodel RiverBend - PeaceHealth - Plan Review For questions, please call CLAIR at (541) 758-1302 Construction Document or Plan Sheet and lD~t,~\ Drawing Section #2 LP-601 City Comment I Applicant Response The illustrated recessed safety showerl eyewash, unit is directly, connected to the drainage system with a trap and vent provided. This type of system would most likely be subject to infrequent use. Traps shall have their water seals protected with an automatic means in such circumstances. Please provide information. Chapter 1007.0 of the OPSC. Page: 12 of 12 Building Permit: COM2005-00836 Response From Response Date Status Condition of Approval 1st Plan Review - August 11, 2005 CLAIR Project No.: 1141-009 CITY OF SPRINGFIELD PLUMBING PERMIT FEES TABLE 5 OML RIVERBEND ANNEX - PEACEHEAL TH TABLE No. 3-C REFERENCE NO. DESCRIPTION a One & Two Family Dwellings - Not Applicable b Single Plumbing Fixture c Sanitary Sewer (1) First 50 Ft. (2) Each additional 100 Ft. or portion d Water Service (1) First 50 Ft. (2) Each additional 100 Ft. or portion e Storm & Rain Drain (1) First 50 Ft. (2) Each additional 1 00 Ft. or portion f Sewage Ejector Pump g Special Waste Connection h Manufactured Homes - Not Applicable I Backflow Prevention Device j Relocated Structure - Not Applicable k Sanitary or Storm Sewer Cap I Any Trap or Waste not connected to Fixture m Any plumbing installation not listed in this schedule with sanitary waste or potable water supply n Minimum Inspection Fee - Not Applicable o Partial Inspection Fee (1) p Reinspection Fee (2) q Inspections Not Covered By Schedule r1lnspections Outside Normal Business Hours sllnvestigation Fee - Not Applicable tlBuilding Without Permit Penalty - Not Applicable ulAccessible Minor Plumbing Labels NO LONGER AVAILABLE - Not Applicable vlNot Accessible Minor Plumbing Labels NO LONGER AVAILABLE - NOT APPLICABLE wlHourly Inspection Fee for Requests Not In Permit Table I I SUBTOTAL State Surcharge Administrative Fee SUBTOTAL Plan Review Fees TOT ALl FEE QTY UMC AMOUNT $14.00 117 $1,638.00 $45.00 $14.00 $45.00 $14.00 $45.00 $14.00 $14.00 2 $45.00 $14.00 $14.00 $45.00 $45.00 $45.00 $45.00 $67.50 $45.00 2 $28.00 $0.00 $45.00 $0.00 @ @ $1,694.00 $118.58 $169.40 $1,981.98 $594.59 $2,576.57 7% 10% @ 30% NOTE 1: Assessment of partial inspection fees TBD NOTE 2: Two (2) inspections allowed, additional inspections required to correct deficiencies at $45.00 each at the inspector's discretion CITY OF SPRINGFIELD MECHANICAL PERMIT FEES OML RIVERBEND ANNEX - PEACEHEAL TH , FEE QTY $12.00 $15.00 $12.00 $12.00 $22.00 $33.00 $44.00 $75.00 $8.00 $15.00 $9.00 $9.00 $6.00 $6.00 $4.00 $1.00 $4.00 $1.00 $12.00 $15.00 $60.00 $30.00 $12.00 $45.00 $9.00 $45.00 $45.00 $10.00 $45.00 $45.00 $67.50 $45.00 $45.00 EXTENDED AMOUNT TABLE No. 3-D REFERENCE NO. DESCRIPTION a HVAC Up to 100,000 btu More than 100,000 btu Unit Heater b Boiler/Compressor Up to 100,000 btu 3 - 15 Horsepower or 100,001 - 500,000 btu Over 15 to 30 Horsepower - 500,00' - 999,000 btu Over 30 to 50 Horsepower or 1,000,000 - 1,750,000 btu Over 50 Horsepower or over 1,750,001 btu c Air Handling Unit Up to 10,000 cfm 10,001 cfm and over Evaporative Cooler/Fan d Vents Hood and Exhaust Vent Fan to One Duct Appliance Vent e Gas Piping Each Piping System 1 -4 Outlets Each Outlet over 4 f Air, Oxygen, Other Medical Specialty Piping Each Piping System 1 -4 Outlets Each Outlet over 4 LP Gas Tank and Piping h Miscellaneous Domestic Incinerator Commercial Incinerator Wood/Pellet Stove - Not Applicable Heat Pump Preliminary Inspection I Each Appliance Not Listed on this Schedule j Inspections Not Covered by this Schedule k Reinspection Fee I Mechanical Insurance Fee m Minimum Permit Fee - Not Applicable n "n" Not Listed In Sch.edule o Partial Inspection (1) p Inspections Outside Normal Business Hours q Investigation Fee (2) r Building Without Permit Penalty - Not Applicable s Hourly Inspection Fee for Requests Not In Permit Tables 59 $885.00 7 $105.00 8 $72.00 5 $45.00 SUBTOTAL $1,107.00 State Surcharge @ 7.00% $77.49 Administrative Fee @ 10.00% $110.70 SUBTOTAL $1,295.19 Plan Review Fee @ 25.00% $323.80 TOTAL $1,618.99