Loading...
HomeMy WebLinkAboutPermit Building 2001-11-27 (2) Job# 01-01030-01 Page 1 of 3 225 North Fifth Street Springfield, OR 97477 COMMERCIAL PERMIT City Of Springfield Community Services Division Building Safety Job Number: 01-01030-01 Office: 726-3759 Inspection Line: 726-3769 location Of Proposed Site: 880. Beltline Rd Spr Assessors Map#: 17031530 lot: Block: Addition: Owner: Address: Tax lot #: 00900 Subdivision: Washington Mutual Bank Phone Number: 206-377-6397 City/State/Zip: Seattle, WA 98101 New ,Value: $175,000 .1' 12013rdAve Scope Of Work: Ba~k Washington Mutual Tenant improvements Contractor Type Architect General Contr Electrical Contr Mechanical Contr Plumbing Contr . Quad Area: # Of Units: Constr. Type: Water Heater: Contractor Registration # Expiration Date Phone James Derby 801-942-1360 2944 E 7320 South, Salt Lake City, UT 84121 R & H Construction Co 38304 12/23/03 503-228-7177 1530 Sw Taylor St, Portland, OR 97205-1819 New Technology Acquisition Corp 41868 10/13/04 503-648-1900 6950 Ne Campus St, Hillsboro, OR 97124-611 Hvac Inc. 50897 6/12/02 503-462-4822 5188 Se International Way, Milwaukie, OR 97222-4602 . Raybonis Plumbing Inc 87852 12/14/03 541-692-4139 19990 SW Cipole Rd, Tualatin, OR 97062 Office Use 1 CNW land Use: Zoning Code: , (VNSPR) Wd Frame-SI Bedrooms: , .' Range: # Of Buildings: 1 Occupancy Group: Office/Professionc Heat Source: Sq. Footage: 4595 To request an inspection call the 24 hour recording at 726-3769.. All inspections requested before 7:00 a.m. will be made th~ same working day, inspections requested after 7:00 a.m. will be made the following working day. . . . Required Inspections Building Framing Drywall Ceiling Grid . I, - Prior to cover. -Prior to taping. Job# 01-01030-01 Page 2 of 3 Required Inspections I ' Building SUB - Ceiling Grid Final Fire Final Building - When all Fire Dep.artment requirements have been met. -When all required inspections have been approved and the building is complete. I Plumbing ~ Prior to insulation or decking. - Prior to cover. - When all plumbing work is complete. Underfloor Plumbing Rough Plumbing, Final Plumbing Construction Types:(VNSPR) W,d Frame-Spr Occupan~y Groups: Office/Professional/Rest # Of Buildings: ':1' # Of Stories: # Of Bedrooms: Current Units: Handicap Access? 0 Census Code: Does not apply -Area (Sq. Feet) Main: 4595 Accessory: Total:4595 Height (feet): Proposed Units: Fee Paid On Receipt# Plan Check 09/20/2001 6750 . 11/27/2001 7343 11/27/2001 7343 Value/Quantity Commercial Plan Check Additional Plan Check Fire & Life Safety Plan Review Total Plan Check 125,000 171 125,000 Building Permit State Surcharge For ,Building permit Building Administrative Fee Total Building, Building 11/27/2001 7343 11/27/2001 7343 11/27/2001 7343 175,000 Minimum Plumbing Permit Fee Number of Fixtures State Surcharge - Plumbing Administrative Fee - Plumbing Total Plumbing Plumbing 11/27/2001 7343 11/27/2001 7343 11/27/2001 7343 11/27/2001 7343 11 Financial Institution - MWMC MWMC Administrative Fee SDC Administrative Eee Office Building -General-Reimbursemel Office Building - General - Improvement Sanitary Sewer SDC Reimbursement Sanitary Sewer SDC,lmprovement Total System Development Grand Total System Development 11/27/2001 7343 11/27/2001 7343 11/27/2001 7343 11/27/2001 ' 7343 11/27/2001 7343 11/27/2001 7343 11/27/2001 7343 5 5 34 34 5 1 Plan Check Type .Checked By Date Completed Comment Initial Review-C/I/P Lisa Hopper .09/21/2001 Fee Amount $420.49 $170.62 $258.76 $849.87 $809.40 $56.66 $64.75 $930.81 $.00 $154.00 $10.78 $12.32 $177.10 $1,061.95 $10.00 $317.90 $740.35 $3,266.91 $726.58 $552.16 $6,675.85 $8,633.63 Bldg envelope only. Need forms & drawings for Mechanical and Electrical deferred submittals, when available. By signature, I state and agree, that I have carefully examined the completed application and do hereby certify that all information hereon is true and correct, and I further certify that any and all work performed shall be done in accordance with the Ordinances of the City of Springfield and the Laws of the State of Oregon pertaining to the work described herein, and that NO OCCUPANCY will be made of any structure without permission of the Community Services Division, Builaing Safety. I further certify that only contractors and employees who are in compliance with ORS 701.055 will be used on this project. ' I further agree to ensure .that all required inspections are requested at the proper time, that each address is readable from the, street, that the permit card is located front of the property, and the approved set of plans will re~ ~~it~1I times dur' o,nstruction. ~. ~/r Signature ~. ~ Job# 01-01030-01 Plan Check Type Checked By Date Cc>mpleted Engineering-C/I/P Pam Ownby, 10/15/2001 Planning-C/I/P Liz Miller 10/10/2001 Structural-C/I/P Tom Rogers . 10/08/2001 Fire Marshal-C/I/P AI Gerard 10/02/2001 SUB - Comm/lnd Jack Foster 09/25/200,1 SUB - Comm/lnd Don Moore SUB - Comm/lnd Jack Foster 10/16/2001 Page 3 of 3 Comment No Planning approval required per Mel Oberst 10/9/01. Tenant Infill. Mechanical plans to be deferred submittal. Plan review - Tenant Infill in existing bldg. - Plans submitted state "Type VN- fully sprinkled", B occupancy, area of bldg= 18,850 sq ft area of work = 4595sq ft . 1. Provide Sprinkler plans for review and approval 2. Provide a minimum of two 2A 1 OB:C fire extinguishers for this occupancy with the maximum travel distance not to exceed 75' and mounted with the handle between 3'and 5' above the finished floor. 3. Provide address #'s in conformance with the existing building's lettering. Need all energy forms to be submitted. Notified Don Moore Requested Form 3a from architect for compliance. Mech. & Elect. are design/build (deferred submittals). I ( ~2- 7-0 ( Date