HomeMy WebLinkAboutPermit Correspondence 1983-6-24
4r-
/
545 CONGER STREET
Pittsburgh
Testing
Laboratory
EU 3786, # 1
EUGENE.OREGON.97402
TELEPHONE; 503'484-9212
June 24, 1983
Emerald Swimming Pools
1885 Pacific Hwy. 99 N.
Eugene, OR 97402
REPORT OF: Reinforcing Inspection (only)
PROJECT: DUri'/ard Boy 1 es Permi t No. 919-83
./-~--------------, .
ADDRESS: ~3415 Baldyview Lane~~
"'---,......-,-.. ..,-....-..-......
DATE OF INSPECTION: June 24, 1983
INSPECTOR: Randy T. Webb, PTL
CONTRACTOR: Em~rald Pools
Rebar - ASTMA-6l5 Grade 40 No. 3
Placement: (4) Continuous in Bond Beam
12" o.c. each way throughout
6" o.c. vertical in haunch
Minimum Ties: Alternate, intersections
Minimum Laps: 9 inches
l-Inch Minus Crushed Rock in bottom
~ ,a.f :::'
,if- ,f 1 .- ,
r V- ....
r
~'
. . . I . .
..~?
Adjustments were to be made in a few al'edS d~ring placement ot gunite
to increase ground clearances.
Respectfully submitted,
PITTSBURGH TESTING LABORATORY
1~~~ .~~t:::~~~r
Eugene District
RTW:ab