HomeMy WebLinkAboutPermit Building 2005-9-27
SITE ADDRESS: 6066 QUARTZ AVE
ASSESSOR'S PARCEL NO.: 1802033400188
TYPE OF USE: New
PROJECT DESCRIPTION: Single family residence- Jaspe.:-~t~ig2nd add lot ~'~t I~ THE \~I()PK
Th)S PERM\'j'SH~tl "10 f~~"'"" ',.IT
TL'ORl/tU U1~ucn '" v ~..",. -
Owner: HAYDEN ENTERPRISES INC AU rl - D~' N 0 FOR
Address: 2622 SW GLACIER PL #110 COlvliviENCED OR IS ABAN VI C
REDMOND OR 97756 ANY 180 DAY PERIOD.
.1
.
Status
Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
541-726-3676 Fax
541-726-3769 Inspection Line
. CITY OF SPRINGFIELD
Building/Combination Permit
PERMIT NO: COM2005-01185
ISSUED: 09/27/2005
APPLIED: 08/30/2005
EXPIRES: 03/27/2006
VALUE: $ 120,208.00
;..'
~pringfield TYPE OF WORK: Single Family Residence
Residential
I CONTRACTOR INFORMATION I
Contractor Type
General
Electrical
Mechanical
Plumbing
Contractor
HAYDEN ENTERPRISES
THORNTON ELECTRIC INC
PACIFIC AIR COMFORT INC
JET MECHANICAL LLC
Phone
541-228-1081
541-686-4151
541-672-9510
503-363-2334
# of Units:
Primary Occupancy Group:
Secondary Occupancy Group:
. Primary Construction Type
, Secondary Construction Type:
# of Bedrooms:
Frontyard Setback:
Side I Setback:
Side 2 Setback:
Rearyard Setback:
Solar Sethacks:
20.00
10.00
10.00
22.00
10.00
Street Improvements:
Storm Sewer Available:
Special Instruction:
License
92208
116329
39237
158633
Expiration Date
07/29/2007
10/01/2006
03/2512006
02/1012006
I BUILDING INFORMATION I
I
R-3
U
VN
# of Stories: I Lot Size:
Height of Structure 16.00 Sq Ft 1st Floor:
Type of Heat: Forced Air Gas Sq Ft 2nd Floor:
Water Type: Gas Sq Ft Basement:
Range Type: ATTEN1H~\llriereg~IHl\G@Qlgft<S8fPQrttJ
Ene.rgy Path:. . follow rul~N}lJ~pte~g,ftlQ.t~gon Utility
Sprmkled Bu1ld'f!Jvtification e!1!nter. ~ffilll'~'!l!<<!:set forth
'r.:. J \''' '-S ~\.-. '_'U I-VU I U UIIUUYlI Vf'\n ;:J;.U;.~UU I-
I DEVELOPMENT INFORMATlON.1 obtain COPie~?i_S bv
,Y PARKING
r-" .,,, ,I,,, r.p~ter. (Note: tl ~I e
Overlay Dist: !,,. ,_ .-; -') U:il:~otlil:t.fication 2
# Street Trees Rqd: C~.ller is 12jJU-332HllDd!capped:
Paved Drive Rqd: Yes Compact:
% of Lot Coverage: 26.50
5,388
1,032
400
3
I PUBLIC IMPROVEMENTS I
Sidewalk Type:
Downspouts/Drains:
Fully Improved
Yes
Setback 5'
Curb and Gutter
Notes: Storm drainage piped to curb face 9/212005 CAS
Paee I or4
Status
Issued
225 Fifth Street. Springfield, OR
541-726-3753 Phone
541-726-3676 Fax
541-726-37691nspection Line
Description
Dwelllnl!s
Garal!e
Tvpe of Construction
V Wood Frame
Garal!e
Fee Description
Plan Review Residential
-Mechanical Issuance Fee-
+ 10% Administrative Fee
+ 70/0 State Surcharge
2 Baths One or Two Family
Addressing Assignment
Appliance Not Listed
Building Permit
Curbcut Permit
Dryer Vent
Exbaust Hoods
Furnace - up to 100,000 btu
Gas Oullets 1-4
Heat Pump
Plan Review Major - Planning
PW Disc - 2nd Permit (Street)
Residence Wiring 1000 Sq Ft
Residence Wiring Ea Addll 500
Sanitary Sewer - Improvement
Sanitary Sewer - Reimbursement
SDC MWMC Administration
SDC MWMC Improvement
SDC MWMC Reimbursement
SDC Sanitary/Storm Admin
SDC Transpo Admin
SDC Transpo Improvement
SDC Transpo Reimbursement
Sidewalk Permit
Storm Drainage Impervious Area
Vent Fan
Willamalane Single Family
Total Amount Paid
.
I Valuation Deserintion I
5 Per Sq Ft
or muillplier
596.00
525.00
Square Footage
or Bid Amount
1,148.00
400.00
Total Value of Project
If pp<, PIi4.I
Amount Paid
5412.04
510.00
5110.19
$77.13
5254.00
531.00
59.00
5633.90
580.00
56.00
59.00
512.00
54.00
512.00
5150.00
5-30.00
5106.00
538.00
$381.40
5501.40
510.00
5865.31
582.03
5107.18
568.00
5805.70
5182.69
580.00
5675.07
518.00
51,000.00
56,701.04
Date Paid
8130/05
9/27/05
9/27/05
9/27/05
9/27/05
9/27/05
9/27/05
9/27/05
9/27/05
9/27/05
9127/05
9/27/05
9/27/05
9/27/05
9/27/05
9/27/05
9/27/05
9/27/05
9127/05
9127/05
9127/05
9/27/05
9/27/05
9/27/05
9/27/05
9/27/05
9127/05
9/27/05
9127/05
9127/05
9/27/05
Pal!e 2 of 4
. CITY OF SPRINGFIELD
Building/Combination Permit
PERMIT NO: COM2005-01185
ISSUED: 09/27/2005
APPLIED: 08/30/2005
EXPIRES: 03/27/2006
VALUE: $ 120,208.00
Value
Date Calculated
5110,208.00
510,000.00
5120,208.00
08/30/2005
08130/2005
Receipt Number
1200500000000001266
2200500000000001346
2200500000000001346
2200500000000001346
2200500000000001346
2200500000000001346
2200500000000001346
2200500000000001346
2200500000000001346
2200500000000001346
2200500000000001346
2200500000000001346
2200500000000001346
2200500000000001346
2200500000000001346
2200500000000001346
2200500000000001346
2200500000000001346
2200500000000001346
2200500000000001346
2200500000000001346
2200500000000001346
2200500000000001346
2200500000000001346
2200500000000001346
2200500000000001346
2200500000000001346
2200500000000001346
2200500000000001346
2200500000000001346
2200500000000001346
.::..~.~~~~.,~.
.
. . '.
.
. CITY OF ~rKll'lul'lJ!,LD
Building/Combination Permit
PERMIT NO: COM2005-0Il85
ISSUED: 09/27/2005
APPLIED: 08/30/2005
EXPIRES: 0312712006
VALUE: $ 120,208.00
Status Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
541-726-3676 Fax
541-726-3769 Inspection Line
Initial Review
Plan nine Review
Public Works Review
09/01/2005
09/01/2005
09/01/2005
I Plan Reviews I
09/01/2005 APP
09/2112005 APP
09/02/2005 APP
SKG
TAJ
CAS
Storm drainage piped to curb face
9/2/2005 CAS
Structural Review
09/0112005
09/21/2005
APP RJB
To Request an inspection call the 24 hour recording at 726-3769. All inspection requested before 7:00 a.m.
will be made the same working day, inspections requested after 7:00 a.m. will be made the following work
day.
I Rpn~If'll"'tiln,n\l
Erosion/Grading Inspection: Prior to ground disturbance and after erosion measures are Installed.
Sidewalk - Setback: After forms are erected but prior to placement of concrete.
Rough Mechanical: Prior to Cover
Final Mechanical: When all mechanical work is complete.
Rough Electric: Prior to Cover
Electric Service: Approval required prior to utility company energizing service.
Final Electric: When all electrical work is complete.
Curbcut - Standard: After forms are erected but prior to placement of concrete.
Ufer Electrical Ground: Install ground rod at footing and call for inspection in conjunction with footing and/or
foundation Inspection.
Footing: After trenches are excavated.
Foundation: After forms are erected but prior to concrete placement.
Post and Beam: Prior to floor insulation or decking.
Floor Insulation: Prior to decking.
Shear Wall Nailing: Before covering sheathing with finish materials.
Framing Inspection: Prior to cover and after all rough in inspections have been approved.
Wall Insulation: Prior to cover.
Ceiling Insulation: Prior to cover.
Drywall: Prior to taping.
Hold Downs Installed: Special Inspection perrormed prior to placement of concrete. Provide report to City
Building Inspector.
Final Building: After all required inspections have been requested and approved and the building Is complete.
Underfloor Plumbing: Prior to insulation or decking.
Paee30f4
.
. CITY OF SPRINGFIELD
Building/Combination Permit
PERMIT NO: COM2005-0I185
ISSUED: 09/27/2005
APPLIED: 08/30/2005
EXPIRES: 03/27/2006
VALUE: $ 120,208.00
Status
Issued
225 Fifth Street, Springfield, OR
541-726-3753 Phone
541-726-3676 Fax
541-726-3769 Inspection Line
UnderOoor Drain: Prior to cover or placement of concrete.
Rough Plumbing: Prior to cover and including required testing.
Water Line: Prior to filling trench and including required testing.
Sanitary Sewer Line: Prior to filling trench and including required testing.
Storm Sewer Line: Prior to filling trench.
Final Plumbing: When all plumbing work is complete.
UnderOoor Mechanical. Prior to insulation or decking and Including required testing.
UnderOoor Gas: After line is installed and required testing and capped if not attached to an appliance.
Rough Gas: After line is installed and required testing and capped if not attached to an appliance.
Gas Service: After line is Installed and line has been connected to a minimum of one appliance including required
testing. Presure test done at this point.
By signature, I state and agree, that I have carefully examined the completed application and do hereby certify that all
information hereon is true and correct, and I further certify that any and all work performed shall be done in accordance with
the Ordinances of the City of Springfield and tbe Laws of the State of Oregon pertaining to the work described herein, and
that NO OCCUPANCY will be made of any structure without permission of the Community Services Division, Building Safety.
I further certify that only contractors and employees who are in compliance with ORS 701.005 will be used on this project.
I further agree to ensure that all required inspections are requested at the proper time, that each address is readable from the
street, that the permit card is located at the front of the property, and the approved set of plans will remain on the site at all
times during construction.
ow~~-::tr
cy-.;2-7-Q:5
Date
Pal!e 4 of 4