Exterior Wall Envelope
-Self-Certification Form
1,JkJ, W~J
owner-builder at the following address:
. am the general contractor or the
.
Cell Colcll\/at. Dt'I.\Je.
Street Address
~-Rf!) .
15 L l-S Pk?:Z.o ({ -~2&>.
City
\
'.
Permlt#
To conform to the 2008 Oregon Residential Specialty Code (ORSC), Section
R703.1.~, I am notifying the building official that I am aware of the exterior wall
envelope requirements of R703.1.1, and hereby certify that the components of
the exterior wall envelope have been installed in accordance with the code
requirements. [Section R703.1.1 is provided for reference on the reverse side of
this form.]
\
'~~~
Signature
, W4-Vi
Date
, '
Revised: 2/8/2010
. . .. . ...
.. .. . .
. . . .. .
. . . . . ..
. . . . . . .
... ... . .
.. .. .. . .
. . . . . . . .
. . . . . .
.. .. . . .
. . . . . . . .
. . . . ... .
Excerpt from 2008 Oregon Residential Specialty Code Section R703, Exterior Covering:
R703.1.1 Exterior Wall Envelope. To promote buil~ing durability, the exterior wall envelope shall
be installed in a manner that water that enters the assembly can drain to the exterior. The envelope
shall consist of an exterior veneer, a water-resistive barrier as required in R703.2, a minimum 1/8
inch space between the water-resistive barrier and the exterior veneer, and integrated flashings as
required in R703.8. The required space shall be formed by the use of any non-cbrrodible furring "
,0- I' ~.. _
strip, drainage mat or drainage board. The envelope shall provide proper integrati6n.6f.flashings:';'.JJ
with the water-resistive barrier, the space provided and the exterior veneer. These'components, in
conjunction, shall provide a means of draining water that enters t.he assembly to the exterior.
<.:' 1" F! )j:, \.' "J1., ,: ')
. _.,\.../J f If .~ ..J ~: J'J '_..
Exceptions:
'" "j.
~ ,--~.J
1.
A space is not required where the exterior veneer is installed over a water-resistive barrier
complying with section R703.2 which is manufactured in a manner to enhance drainage and
meets the 75% drainage efficiency requirement of ASTM E2273 or other recogriiz~d":- G \ ': ..
.' .
national standards. .
A space is not required where window sills;are.equipped'with.panflashings which drain to
~J_','~._j './ '. .J'''''l ~ '._ I' '..J
the exterior surface ofthe veneer in '-through wall fashion: All pan flashings shall be. .
detailed within the construction documents and shall be of either a self-adhering
membrane complying with AAMA 711-07 or of an approved corrosion-resistant material or
a combination thereof. Self-adhering membranes extending to the exterior surface of the
veneer shall be concealed with trims or other measures to protect from sunlight.
A space is not required where the exterior veneer is manufactured in a mariner to enhance
drainage and meets the 75% drainage efficiency requirements of ASTM E2273 or other
recognized national standards and is installed over a water resistive barrier complying with
section R703.2.
A space is not required where the exterior veneer is matching an existing exterior finish as
in additions, alterations, or repairs.
A water-resistant exterior wall envelope shall not be required over concrete or masonry
walls designed in accordance with Chapter 6 and flashed according to section R703.7 or
R703.8.
Compliance with the requirements for a means of drainage, and the requirements of,- -;
Section R703.2 and Section R703.8, shall not be required for an exterior w~lI.envelcipe that '
.___. ,I
has been demonstrated to resist wind-driven rain through testing of the exterior wall
envelope, including joints, penetrations and intersections with dissimilar materials, in
accordance with ASTM E 331 under the following conditions: t. " -.,
6.1. Exterior wall envelope test assemblies shall include at least one openin'g/one control
joint, one wall/eave interface and one wall slil. All tested openings and penetrations
shall be representative of the intended end-use configuration.
6.2. Exterior wall envelope test assemblies shall be at least 4 feet by 8 feet in size.
6.3. Exterior wall assemblies shall be tested at a minimum differential pressure of 6.24
pounds per square foot.
6.4. Exterior wall envelope assemblies shall be subjected to a minimum test exposure
duration of 2 hours.
The exterior wall envelope design shall be considered to resist wind-driven rain where the
results of the testing indicate that water did not penetrate: control jOints in the exterior
wall envelope; joints at the perimeter of openings penetration; or intersections of
terminations with dissimilar material's.
2.
3.
4.
5.
6.