HomeMy WebLinkAboutPermit Building 1995-9-12
, I'
SPRINGFIELD
Page 1
RESIDENTIAL PERMIT APPLICATION
CITY OF SPRINGFIELD
COMMUNITY SERVICES DIVISION
BUILDING SAFETY
Job Number: 951341
225 North Fifth Street
Springfield, OR 97477
Office: 726-3759
Inspection Line: 726-3769
Location of Proposed Work: 5749 RIDGE CREST DR
Assessors Map #: 18020414
Lot: 17 Block:
Tax Lot #: 01300
Subdivision: RIDGE CREST
Owner: JOE BANDO
Address: 658 SOUTH 57TH #14
Phone #:
City/State/Zip: SPRINGFIELD, OREGON 97478
Describe Work: MANDF. HOME & GARAGE
NEW
Contractor
Cons t .
Contractor #
Expires
Phone
General: STINNETT 0055720
PO Box 281 Springfield OR 974770000
Electrical: HAUCK HAMMER 0089423
353 S 68th Place Springfield OR 974
02/18/95
746-7003
03/05/96
744-1165
QUAD AREA: 3RSC
# OF UNITS: 1
CONSTR. TYPE: VN
WATER HEATER: E
OFFICE USE --
LAND USE: 1150
ZONING CODE: LDR
# OF BDRMS: 3
RANGE: E
# OF BLDGS: 1
OCCY GROUP: R3
HEAT SOURCE: FE
SQ FOOTAGE: 1692
To request an inspection, call the 24 hour recording at 726-3769.
All inspections requested before 7:00 a.m. will be made the same working day,
inspections requested after 7:00 a.m. will be made the following work day.
REQUIRED INSPECTIONS
PEDESTAL - Prior to cover.
FOOTING - After trenches are excavated.
FOUNDATION - After forms are erected but prior to concrete placement.
SANITARY SEWER LINE - Prior to filling trench.
STORM SEWER LINE - Prior to filling trench.
WATER LINE - Prior to filling trench.
ROUGH ELECTRICAL - Prior to cover,
FRAMING - Prior to cover.
MANDF HOME/MOBILE HOME SET UP - When all blocking is complete.
MANDF. HOME/MOBILE HOME ELECTRICAL - When blocking, setup, and
plumbing inspections have been approved and home is connected to panel
MANDF. HOME/MOBILE HOME PLUMBING - After home has been connected to
water and sewer.
CURB CUT - After forms are erected but prior to placement of concrete.
SIDEWALK - After excavation is complete, forms and sub-base material
in place.
FINAL ELECTRICAL - When all electrical work is complete.
FINAL BUILDING - When all required inspections have been approved and
the building is complete,
FINAL SET UP - After all required inspections are approved and porches
skirting, decks, venting, house numbers, etc. have been installed.
Lot Faces: N
Setbk From NPL: 18
Lot Sq. Ft.: 7575
Solar Approved: Y
Total Height: 15
Lot Type: CORNER
House
Garage
N
24
18
Setbacks
S W
10 26
14
E
20
, .'
Job Number: 951341
Page 2
Item
Main
Garage
FTG/FND FOR HOME
Total Value
BUILDING PERMIT ---
Square Feet x $/Square Feet
672 14.10
Value
137,025,00
9,475.00
3,500.00
150,000.00
Building Permit Fee
Surcharge/Admin
98.50
7,89
TOTAL FEE
(A)
106.39
--- SYSTEMS DEVELOPMENT CHARGE (SDC) ---
(B) 2,360.35
Systems Development Charge is due on all undeveloped properties within the City
limits and the Citys Urban Growth Boundry which are being improved.
PLUMBING PERMIT
Item
Sanitary Sewer
Water
Storm Sewer
50
50
50
Fee
25.00
25,00
25.00
Plumbing Permit
Surcharge/Admin
75.00
6,00
TOTAL CHARGE
(C)
81. 00
--- MISCELLANEOUS PERMITS ---
Mobile Home
State Issuance
Surcharge/Admin
Sidewalk
Curb Cut
WILLAMALANE SDC
ELECTRICAL PERMIT
PLAN CHECK FEE
105.00
20.00
8.40
36.10
15.40
1,000,00
88.56
60.13
TOTAL MISCELLANEOUS PERMITS
(E)
1,333.59
(Excluding Electrical)
unless otherwise noted
TOTAL AMOUNT DUE
(A, B, C, D, and E combined)
3,881.33
-- - BUILDING VALUE, PLAN CHECK AND BUILDING PERMIT ---
This permit is granted on the express condition that the said construction
shall, in all respects, conform to the Ordinance adopted by the City of
Springfield, including the Development Code, regulating the construction and
use of buildings, and may be suspended or revoked at any time upon violation
of any provisions of said ordinances.
- - - ADDITIONAL COMMENTS - - -
SPRINGFIELD
Job Number: 951341
Page 3
ESTIMATE ONLY ON A & T
GARAGE PLANS REVIEWED AND APPROVED BY DON MOORE
DRIVEWAY REQUIRED TO BE PAVED
4' STREET TREES REQUIRED
By signature, I state and agree, that I have carefully examined
the completed application and do hereby certify that all information hereon
is true and correct, and I further certify that any and all work performed
shall be done in accordance with the Ordinances of the City of Springfield,
and the Laws of the State of Oregon pertaining to the work described herein,
and that NO OCCUPANCY will be made of any structure without permission of the
Community Services Division, Building Safety. I further certify that only
contractors and employees who are in compliance with ORS 701,055 will be
used on this project.
I further agree to ensure that all required inspections are requested at the
proper time, that each address is readable from the street, that the permit
card is located at the front of the property, and the approved set of plans
on the site at all times during construction.
will gn
'~oL
.k
7~ (!~?r
Signature
Date
-- - VALIDATION
Date Paid:
j.g?'i F
'Y~2/5' I
-.fl./-- __ ' -S~cp; /. .5 3
~~
Receipt Number:
Amount Received:
Received By:
"
.~\ .
, ",,,!-;'
SPRINGFIELD
CITY OF SPRINGFIELD SYSTEMS DEVELOPMENT CHARGE
(COMMERCIAL / RESIDENTIAL)
Name or Company: JOE BANDO
Location: 5749 RIDGE CREST DR
Developement Type: R Building Size:
1. STORM DRAINAGE
Impervious Sq Ft
2794
x
0,210
2. SANITARY SEWER - CITY
Number Of PFUs 20
(see Page 2)
x
43,43
3. TRANSPORTATION
Number Of Units
1 X
X Trip Rate
1. 010 X
Job No.: 951341
Lot Size:
Per Sq Ft =
Per PFU
x
Cost Per Trip
437.93
$442,31
Transportation Total
4. SANITARY SEWER - MWMC
Number Of PFUs
20
X
X
Per PFU +
18.750 +
MWMC CREDIT If Applicable (see Page 2)
TOTAL - MWMC SDC
SUBTOTAL - (Add Items 1, 2, 3 & 4)
5. ADMINISTRATIVE FEES
Base Charge (Subtotal Above) X
0.50
TOTAL SDC
Reviewed By: TROY MCALLISTER
MWMC Admin Fee
10.00
Date: 08/29/95
Page 1
Sq Ft
$586.74
$868.60
$442.31
$385,00
$34,70
$350,30
$2,247.95
$112.40
$2,360.35
Job Number: 951341
FIXTURE UNIT CALCULATION TABLE
Page 2
Fixture Type
Bathtub
Drinking Fountain
Floor Drain
Interceptors For Grease/Oil/Solids/Etc
Inteceptors For Sand/Auto Wash/Etc
Laundry Tub/Clotheswasher
Clotheswasher - 3 Or More
Receptor For Refrigerator/Water Station/Etc
Receptor for Commercial Sink/Dishwasher/Etc
Shower, Single Stall
Shower, Gang
Sink, Bar, Commercial
Urinal, Stall/Wall
Wash Basin/Lavatory, Single
Water Closet, Public Installation
Water Closet, Private
Miscellaneous
TOTAL FIXTURE UNITS
Number of
New Fixture
Unit
Equivalent
Fixture
Units
2
o
o
o
o
1
o
o
o
1
o
1
o
2
o
2
o
2
1
2
3
6
2
6
1
3
2
4
o
o
o
o
2
o
o
o
2
o
2
o
2
o
8
o
2
2
1
6
4
20
CREDIT CALCULATION TABLE: Based on assessed value, If improvements occured
after annexation date, credits are calculated separately.
(calculations are by $1000)
Year Annexed: 1979
Credit For Parcel Or Land Only If Applicable:
Improvement (if after annexation date) :
10,000
X
3.47
34,70
o
X
3.47
0.00
CREDIT TOTAL =
$34.70
(If land value is multiplied by 1 then the parcel/land credit is not accurate.)
.
DEVELOPMENT SERVICES DEPARTMENT
225 FIFTH STREET
SPRINGFIELD, OR 97477
(503) 726-3753
FAX (503) 726,3689
MANUFACTURED HOME SET-UP AGREEMENT
As required by the City-of Springfield Development Code, I understand and
tha t wi th the approval of the attached permi ts h. on~ ~{ the ~llo,\irill.":>
manufactured homes will be placed at. _ '~:Si~'-'\ ~\{\(\'l,... \J\Or:ro \\f
Springfield, Oregon, Ci ty Job Number U S \_~ \ ~
(/
agree
Tyve I Manufactured Home. A multi-sectional (double wide or wider)
unlt with an enclosed tloor area of not less than 1,000 square feet,
that has a nominal roof pitch of 3 feet in height for each 12 feet in
width, that has no bare metal siding or roofing, and that has been
certified by the manufacturer to have an exterior thermal envelope
meeting performance standards which reduce heat loss to levels
equivalent to the performance standards required of single family
dwellings a6Rstr~et9g ~Ra:~ ~~~a~c 3p~~~gl~~ Cases. Gd\ ~~
~ Cl\:J ~00-
Type II Manufac'tured Home. A uni t of not less than 12 feet in width
with an enclosed tloor area of not less than 500 square feet, that has
a nominal roof pitch of 2 feet in height for each 12 feet in width and
that has no bare metal siding or roofing.
,
I further state, by my signature below, that I have been provided with the
following information:
_ Manufactured Home blocking
- Yater line connection
_ Street tree standards
- Sanitary sewer connection
- Electrical connection
_ Minimum requirements for permanent steps
I also understand that if I am installing a Type I Manufactured Home, the home
shall be enclosed at the perimeter with stone, brick or other masonry materials,
and with no more than 12 inches of the enclosing material exposed above grade.
Dlct-
Signature
'\ Q a_~ ___=-.1.r
1-/(- 75
Date
.'
"