HomeMy WebLinkAboutSpecial Inspection Field Test & Inspection Report 2005-10-6 : I," i~ ~ J;: '"" '). i.. ,r HILL & DALE ENGINEERING, LLC 74 EAST 18TH AVENUE, SUITE #5 EUGENE, OREGON 97401 (541) 868-0667 FAX: (541) 868-0888 Page: lIZ Date: 10/04i05 Client: Josh Stauber 3656 Ambleside Dr. Springfield, ~R 97478 Locatlon:.3656 Ambleside Dr. Contact: Job Description: Retaining wall inspection Job Number: 571-05 Design Criteria: -OSSC '04' and '98' and ORSC '05' -Exposure B -80mph.winds -Seismic Design Category D 1 -Soil bearing pressure 1500 psf for design * A site visit was performed at the above location to inspect the gravity retaining wall that has . been installed at the back property line. A review of pictures taken at the site during installation, and the working detail used was performed by this office. This criteri~ was. used to check the design used by'using this data in the Anchor Wall Systems design prognim. This working detail -is satisfactory for the installed wall. I was informed thaUhis-wallrequiredrepair. A review of the picture showing the fail~e and inspection of the site conditions, indicates that the failure of the wall was due to undermining the base of the wall at the adjoining property. The repair included embedding 2 courses below grade to ensure the base of the wall and leveling pad was replaced on . 'I . . solid, undisturbed native grade. It is important that these types of walls are placed on solid native grade and are not undermined. Undet.minmg the base.ofthe wall will cause the, sagging failure that is shown on the pictures taken oftthe failure. Attached is the working detail used for the installation of the wall. The wall apPfars to be perfonning well at this time.