Loading...
HomeMy WebLinkAboutMiscellaneous Compliance Report 2011-8-3 \. \ iit~:;~ENT. LLe C .c.'J Exterior Wall Envelope Self-Certification Form I, f-h1lc'fC.) ",-...J (,~ ""-'--'<, owner-builder at the following address: , i < I \ \ t./'f< L.- UoU-y ~., Street Address 'H'l..{ ~c., ~ (c'\..<i::. City S-P(Z-Z--D Il -lJLt~. 130)' Permit# . am the general contractor or the To conform to the 2008 Oregon Residential Specialty Code (ORSq, Section R703.1.1, I am notifying the building official that I am aware of the exterior wall envelope requirements of R703.1.1, and hereby certify that the components of the exterior wall envelope have been installed in accordance with the code requirements. [Section R703.1.1 is provided for reference on the reverse side of this form.] ~/ -n- ) Sign.rtu re / i g-"]-(( Date ,// Revised: 2/8/2010 Excerpt from Z008 Oregon Residential Specialty Code Section R703, Exterior Covering: R703.1.1 . Exterior Wall Envelope. To promote builaing durability, the exterior wall envelope shall be instailed in a manner that water that enters t,he assembly can drain to the exterior. The envelope shail consist of an exterior veneer, a water-resistive barrier as required in R703.2, a minimum 1/8 inch space between the water-resistive barrier and the exterior veneer, and integrated flashings as required in R703.8. The required space shail be formed by the use of any non-corrodible furring strip, drainage mat or drainage board. The envelope shail provide prop~r integration of flashings with the water-resistive barrier, the space provided and the exterior veneer. These components, in conjunction, shail provide a means of draining water that enters the assembly to the exterior. Exceptions: 1. A space is not required where the exterior veneer is instailed over a water-resistive barrier complying with section R703.2 which is manufactured in a manner to enhance drainage and meets the 75% drainage efficiency requirement of ASTM E2273 or other recognized national standards. 2. A space is not required where window sills are equipped with pan flashings which drain to the exterior surface of the veneer in a through wail fashion: Ail pan flashings shail be detailed within the construction documents and shail be of either a self-adhering membrane complying with AAMA 711-07 or of an approved corrosion-resistant material or a combination thereof. Self-adhering membranes extending to the exterior surface of the veneer shail be concealed with trims or other measures to protect from sunlight. 3. A space is not required where the exterior veneer is manufactured in a manner to enhance drainage and meets the 75% drainage efficiency requirements of ASTM E2273 or other recognized national standards and is instailed over a water resistive barrier complying with section R703.2. 4. A space is not required where the exterior veneer is matching an existing exterior finish as in additions, alterations, or repairs. 5. A water-resistant exterior wail envelope shail not be required over concrete or masonry wails designed in accordance with Chapter 6 and flashed according to section R703.7 or R703.8. 6. Compliance with the requirements for a means of drainage, and the requirements of Section R703.2 and Section R703.8, shall not be required for an exterior wail envelope that has been demonstrated to resist wind-driven rain through testing of the exterior wall envelope, including joints, penetrations and intersections with dissimilar.materials, in accordance with ASTM E 331 under the following conditions: 6.1. Exterior wall envelope test assemblies shail inClude at least one opening, one control joint, one wail/eave interface and one wall sill. Ail tested openings and penetrations shail be representative of the intended end-use configuration. 6.2. Exterior wail envelope test assemblies shail be at least 4 feet by 8 feet in size. 6.3. Exterior wail assemblies shail be tested at a minimum differential pressure of 6.24 pounds per square foot. 6.4. Exterior wail envelope assemblies shail be subjected to a minimum test exposure duration of 2 hours. The exterior wail envelope design shall be considered to resist wind-driven rain where the results of the testing indicate that water did not penetrate: control joints in the exterior wail envelope; joints at the perimeter of openings penetration; or intersections of terminations with dissimilar materials. , , ,. / , \ '\. ~ 225 FIFTH STREET SPRINGFIELD, OR 974n PHONE (541)726-3753 FAX (541)725-3689 . wWw.ci.springfield.cr.us. MOISTURE-CONTENT ACKNOWLEDGEMENT FORM \ , -~---" \ , , \ \ . I f!l-r+y':/)I~ M..or..;.~ , buiJaer anlie following aililress: . , am the general contractor or the owner- \ \ I I (l"fc 1- ./.1.oI,<-V Street Address . <; ?~I ,.J C:" ;.: \(:-L\::J CitY <;~\2..-2DI \ - \ ~L~S Permit # ,- . , If applicable: ~. Uc.. wC'>~(,..>~'" Subdivision/Lot Map and Tax Lot To conform with the 2008 Oregon Residential Specialty Code (ORSC), Section R3l8.2, I am notifying the builcling official that I am aware of the moisture content reqUirement of ORSC Section iu 18.2 and .have taken steps to meet this code requirement. [Section R3l8.2 is provided for ref~ence.] (' Section R318.2 Moisture content. Prior to iSsuance of the insulation/vapor barrier approval required by R109.1.5.2 of this code: ... . (A) All moisture-sensitive wood framing members Used in cunstruction shall have a -moistiiIecqhtep.t"6Jnot more thiiri.19.perceiit oftlie weighfofarywood frii:iriiig members. (B) The general contractor or the oWher who was issuedtlie structural perinit shall notify the building official on a division approved form that the contractor or the owner who was issued the structural permit is aware of and has taken steps to meet the . requn:ement in paragraph (A). . ._f/..X . Jlc3 d( Signature Date l:\Moisture Content Ac:Jmol't' Form.dac