HomeMy WebLinkAboutMiscellaneous Specifications 2011-7-28
1;g: CIT"f of Sft,(Ic,-f,'! (<::/ 'R~" 46SQ''A'' ST J Sf' -sPR.. 2011-oo4-'f4
4- ,lfl-!> Jf,JT~R.lo~ PAIN T P(l...oDlJO' S+lAL{. F->/EO ()$t:;[J
110 PLAcE' ar A td J'f'L. VAPa~ BAa.Al~~ flPPLIISl:> (jvER.
-rHG I'll ALL BATT IN $ULAT/oJ,J 108.17
~~;?t 7~2B-Jf
L> f . INTERIOR LATEX
FoDo,/ o"{ orA.
<5/511//&,,41 FtJfL HoiffANftMOISTURE VAPOR BARRIER
CoN:!>T. C.OD oJATD~ PRIMER/FINISH
872W1
~ . .6
SHERWIN
WILLIAMS.
.
.
.
No
CHARACTERISTICS
Interior Latex Moisture Vapor Barrier
Primer/Finish is a coating designed to
reduce the loss of moisture through
walls and ceilings.
Moisture Vapor Barrier Primer/Finish
combines a primer and finish in a single.
fast drying coat.
Moisture Vapor Barrier Primer/Finish
is specially formulated for manufactured
housing facilities.
Upon field installation ofthe home. this
product can be topcoated with any Sher-
win-Williams' interior latex or alkyd prod-
uct.
Color: White
Coverage: 200 - 250 sq ftIgal
@ 6.0 - 8.0 mils wet; 1.8 - 2.4/mils dry
Drying Time @ 77'F 50% RH
(temperature and humidity dependant)
To touch: 1 hour
To topcoat: 4 hours
Finish: 0 - 10 units @ 85'
Flash Point: N/A
SolyentlReducer: Water
Tinting with Blend-A-Color:
Base oz/gal
White 0-4
Vehicle Type:
Vinyl Acrylic/Styrene Butadiene
VOC (less exempt solvents):
73 g/L; 0.61 Ib/gal
26:t2%
Strength
75%
Volume Solids:
Water Vapor Permeance
ASTM E96 A iess than 1.0 perm
Weight Solids: 40 ::I: 2%
Weight per Gallon: 10.31b
0412011
T
A M
N
N
N
No
y
N
N
No
No
MPI Sec'
NGBS
SPECIFICATIONS
Drywall
System 1:
1-2 ct5. Moisture Vapor Barrier Primerl
Finish
System 2:
1 ct. Moisture Vapor Barrier Primerl
Finish.
2 cts. Sher:win-Williams Interior, LaR
tex or Alkyd. Architectural Top-
coat
APPLICATION
Do not thin....Reduetion will adversely.
~.ffect the perm rating.
Apply at temPeratures above 50'F.
Brush - Use nylon/polyester brush
Roller - Use 3/8. - 3/4" nap cover
Spray - Airless
Pressure ................................ 2000 psi
Tip ......................................017"..019.
www.sherwin-williams.com
SURFACE PREPARATION
WARNING! Removal of old paint by
sanding, scraping o,r other means may
generate dust or fumes that contain
lead. Exposure to lead dust or fumes
may cause brain damage or other ad-
verse health effects. especially in chil-
dren or pregnant women. Controlling
exposure to lead or other hazardous
substances requires the use of proper
protective equipment, such as a prop-
erly fitted respirator (NIOSH approved)
Clnd proper contain'ment and cleanup.
For more information, call the National
Lead Information Center at 1-800-424-
LEAD (in US) or contact your local
health authority.
Remove. all surlac~ contamination by
washing wj~~.- an appropriate cleaner,
. rinse thoroughly and allow to dry.
Scrape and' sand . peeled or checked
paint to a sound surface, Sand glossy
surfaces ~ull. Seal stains from water,
smoke; ink,' pencil, grease, etc. with the
appropriate primer/sealer. ..
. .
Drywall
Fill. Rracks.: and ~oles. with, patching
pasteJspackle and ~sa.nd 'smooth. Joint
com~pounds ml:l~t'~~,e:cured and sanded
smooth. Rern9':'~ .al.I,.s~J?ding dust.
CLEANUP INFORMATION
Clean spills, spatter.., hanas and tools
immediatelx after use wfth. .soap and
warm water. After""c!eaning"fluSh spray
equipment with ,mineral spirits to pre-
vent rusting ,of the equipmerit. Follow
manufacturer's safety recommendations
when using mineral,spirits.
continued on back