HomeMy WebLinkAboutPermit Mechanical 2011-8-3
SP:..:~.~._ mL~
.;<~
/,,~\;':i~ OIUGO~
CITY OF SPRINGFIELD
225 Fifth SI
Springfield,OR 97477
Phone: 541-726-3753
Inspection Phone: 541-726-3769
Fax 541-726-3676
www.cLspringfield.or.us
Building I Commercial Permit
PERMIT NO: 811-SPR2011-01885
IVR Number: 811111319387
permitcenter@cLspringfield,or.us
PROJECT STATUS:
STATUS DATE:
Issued
08/03/2011
ISSUED:
APPLIED:
08/03/2011
08/03/2011
EXPIRES:
VALUE:
01/29/2012
$0.00
SITE ADDRESS: 202 S 18TH ST, Springfield, OR 97477
ASSESOR'S PARCEL NO: 1703360000500
SCOPE: Mechanical Only
WORK INVOLVED: Alteration
TYPE OF STRUCTURE: Public
PROJECT DESCRIPTION:
Split heat pump- RTU weight less than 200#
OWNER:
ADDRESS:
CITY OF SPRINGFIELD
202 S 18TH ST
SPRINGFIELD OR 97477
Phone Number: 541-744-3765
Contractor Type
Mechanical' Contractor
Contractor Name
EUGENE HEAliNG INC
CONTRACTOR INFORMATION ~
Lie Type
CCB
BUILDING INFORMATION ~
Lie No
188592
Lie Exp
11/05/2011
Phone
541-726-7656
# of Units:
o
Lot Size:
Sq Ft 1 st Floor:
Sq Ft2nd Floor:
Sq Ft Basement:
Sq Ft Garage:
Sq Ft Carport:
Sq Ft Other: 0
ATTENTIOI~:cewb'!J'5Y, ~&i\d;'equires you to
Electrical Specialty Code Edition: follow rules adopted by the Oregon Utility
Springfield Fire Code Edition: Notification Center. Those rules are set forth
. OAR 9~?-n01-0010through OAR 952-001-
Mechanical Specialty Code EditioW. '2010 bta'ln copies of the rules by
. . 0090. You may 0
MUnicipal I Development Code: calling the center. (Note: the telephone
Plumbing Specialty Code Edition: number for the Oregon Utility Notification
Residential Specialty Code Edition: Center is 1-800-332-2344).
Structural Specialty Code Edition:
# of Stories:
Height of Structure:
Type of Heat:
Water Type:
Range Type:
Hazmat:
# of Bedrooms:
Sprinkled Building:
Fire Alanns:
Energy Path:
Site Infonnation
~
Engineered Fill:
Fill Volume:
Flood Hazard Area:
land Hazard Area:
Retaining Wall:
Soils Report Required:
...,..'( ...
NOTICE: .. RK
THIS PERMIT SHALL EXPIRE IF 1HEI~~OT .'
AUTHORIZED UNDER THIS PERMIT. .'
COMMENCED OR IS ABANDONED FOR ;,';' .
ANY 1 SO DAY PERIOD. .. .: .:.
Springfield Building Permit
8/3/2011 1:41:54PM
Page 1 of 3
S~:~~NG.=L~
Br,~,,..,
~." " "OREGON
www.ci.sprlngfield.or.us
CITY OF SPRINGFIELD
Building I Commercial Permit
PERMIT NO: 811-SPR2011-01885
IVR Number: 811111319387
225 Fifth St
Sprin9field,OR 97477
Phone: 541-726-3753
Inspection Phone: 541-726-3769
Fax: 541-726-3676
pef1Tlilcenter@ci,springfield.or.us
PROJECT STATUS:
STATUS DATE:
Issued
0810312011
ISSUED:
APPLIED:
0810312011
0810312011
EXPIRES:
VALUE:
0112912012
$0.00
SITE ADDRESS: 202 S 18TH ST, Springfield, OR 97477
ASSESOR'S PARCEL NO: 1703360000500
SCOPE: Mechanical Only
WORK INVOLVED: Alteration
TYPE OF STRUCTURE: Public
PROJECT DESCRIPTION:
Frontyard Setback:
Interior Setback:
Sideyard Setback:
Rearyard Setback:
Solar Setback:
Split heat pump- RTU weight less than 200#
DEVELOPMENT INFORMATION I
Overlay Dist:
# Street Trees Reqd:
Paved Drive Reqd:
% of lot Coverage:
Highest point on structure
to north property line:
REQUIRED PARKING
Total:
Handicapped:
Compact:
PUBLIC IMPROVEMENTS
I
Street Improvements:
Storm Sewer:
Storm Sewer Available:
Speciallnstructon:
Subdivision Accepted:
Notes:
Sidewalk Type:
Downspout/Drains:
Valuation Description
I
Description
Tvoe of Construction
Unit Amount Unit Tvoe
Unit Cost
Value
FEES PAID
I
Description
State of Oregon Surcharge (12% of applicable fees)
Mec~anical Per~1t fee (based on vallie of wor'9.._
Technology fee (5% of permit total)
Total Amount Paid
Amount Paid
$14.16
$118.00
$5.90
$138.06
Date Paid
08/03/2011
08/03/2011
08/03/2011
Recio! #
2011002179
2011002179
2011002179
Springfield Building Permit
8f3/2011 1:41:54PM
Page 2 of3
S~~ING. F,IE,L~
.'
'~. ~
.+~0' OREGON
CITY OF SPRINGFIELD
Building I Commercial Permit
PERMIT NO: 811-SPR2011-01885
IVR Number: 811111319387
www.ci.spr"lngfield.or.us
225 Fifth St
Springfield,OR 97477
Phone: 541.726-3753
Inspection Phone: 541-726-3769
Fax: 541-726-3676
perm itcenler@ci.springfield.or.us
PROJECT STATUS:
STATUS DATE:
Issued'
08/03/2011
08/03/2011
08/03/2011
ISSUED:
APPLIED:
EXPIRES:
VALUE:
01/29/2012
$0.00
SITE ADDRESS: 202 S 18TH ST, Springfield, OR 97477
ASSESOR'S PARCEL NO: 1703360000500
SCOPE: Mechanical Only
WORK INVOLVED: Alteration
TYPE OF STRUCTURE: Public
PROJECT DESCRIPTION:
Split heat pump- RTU weight less than 200#
Plan Review
~
Deoartment
Application Acceptance
Received Due Date
08/03/2011 08/03/2011
Result
Over the Counter
Comoleted
08/03/2011
Mechanical Review
08/03/2011 08/03/2011
08/03/2011
Not Required
Comments: Over the counter permit
I~i!ial R,eyi~w 7 - L ':<:''''4 ", 08/03/it9,1,1,;,:08/03/291.t;f~08/03/201\
,HC,. ."2.....::.. ':' -:"".1:,"10::.::':" __+,,>"~..-_7,' ":"':"/-'."'zi.Xi:"-"'"'''' , .<"f,
"'Cpm'in~n.t~:,'<+9yerthe'co~l"),terE!?ern:1It' - _,t!"'i'~';,;"-';". _,",-:'_".:' ;~'~
~_.~"n',",~'...'-'-.' . .__ ,;-' . ,~
Reviewer
Chris Carpenter
Chris Carpenter
b;y~!,'!!i~i(P~YPt~'r~~sXd, -- ~t1rls C~rpe(l~e~'.: '-'._
" .,m ;""'~11~~1.~.:~'tt,+r. _,.", ~. ~ ";~J:+-
INSPECTIONS REQUIRED ~
Inspections
2300 Rough Mechanical
2999 Final Mechanical
Rough Mechanical: Prior to Cover
Final Mechanical: When all mechanical work is complete.
By signature, I state and agree, that I have carefully examined the completed application and do hereby certify that all
information hereon is true and correct, and I further certify that any and all work performed shall be done in accordance with the
Ordinances of the City of Springfield and the Laws of the State or Oregon pertaining to the work described herein, and that NO
OCCUPANCY will be made of any structure without permission of the Community Services Division, Building Safety. I further
certify that only contractors and employees who are in compliance with ORS 701.005 will be used on this project. I further agree
to ensure that all required inspections are requested at the proper time, that each address is readable from the street, that the
permit card is located at the front of the property, and the approved set of plans will remain on the site at all times during
~,,"""'"" tf/c4
c ~c2ij ;?~
Owner or Contractor Signature
tfi
Springfield Building Permit
8/3/2011 1:41:54PM
Page 3 of 3
Mechanical Permit Application
225 Fifth Street. Springfield, OR 97477. PH(541)726-3753 . FAX(541)726-3689
"'''!.';t;;?;,l-.'''i''~C'''~'~I'"",:-,',F''"&.~;'';;;;~ ~6L'_~~'-i"~!?i;"" '<>.;:'~"',..,,'J~,)::,{
:';,l:':OERARfMEN:r;USE'ONLY,";:;"'j
:.,,;.-: ; "'\,;:,-\<l,~~."",<:.'[i\,,"".'!' ,;_;. "k,.j~.;. :.::""':'~;.;:; ":~'.:I.'A..";' .lL',:"lt$
This permit is issued under OAR 918-440-0050, Permits expire if work is not started within 180 days of issuance or if work is
suspended for 180 days,
:;:,~ttii7?~~'~icWif~Q'ORX4Q~;)f9bNS't@qJlqN'~~~:'~:1}\'~" ".'.
o Residential 0 Government '}Q Commercial
~r'I!i~JbB"Isf;ftE',m;j'F:ORi'\ifA:rIOtIi~;AND(:<i!0i>A:J;[ON!ii,1I1iir:;iii
. .:~: ."~', .. " '..; _._, '_._ ". ..' "; _ .,_,_ ", _, ~_._,,_:, -., .,.. :,-"_,'n.,_ ~_ ..'.._ ... ,', '.. y,\.... ..,_..._, .......'".__._-,__ c.,;1.,:, ,_ ..';;"
Job site address~b 2-- S. / ff -I-;{ s+-
City: "-- ,) v1lY>e U, J_O I Stat0t I ZIP: 4 )1.(< 7
Referen e: l Taxlot:
"'DESCRIPTibt-l3>FWqRK:" :'.'
!1l\f) .J)udfd, 'S ik-Ai L/ f)
u
~-t";;rl/j~
Address: Zo 2- I 5 / rf L 5-f-.
City: <0o/t ' ('7- / J I StatetV'-
PhoneU - "'?-U/-37b J- I Fax
-. ;
I ZIP9 1l/ 7;
E-mail:
This installation is being made on property owned by me or a
member of my immediate family, and is exempt ITom licensing
requirements under ORS 701.010,
Signature:
~1i:R:%~;'1~c6N:r;R.AC;f:0R1'liNsTAi:!UAtloN1~I!~'J,$i,'i",f~W;;l':;~
2:;;:~::::~e;;(ff~~~;;:~':;f A'~( C'tUM\~~ (':;c, )
Address:.:X ~ F,&,fh?i::l----" A/v (;)
City: c"o- ., I State: eve I 'ZIP:CJJ 7 (1$
Phone: v_ --PC' 76 s-~ I Fax: - -
E-mail ho..~(fJ.r4td::.mdl<.-!Iedeo. ~
CCB license no,: / ,fffS-l?_
Print name: ~~'^V\.. ~+l-e-I
Signature:--:7, ..k?- ~ f/
(2T7A. ~ I s-o#-
440-2545-J (I l/OS/COM)
."'.X, -'::;''''FEE SCHEDULE
',',.".,,::."
"
"Reija~titiaHK.'it;'<I;,Ci;i!~.h,,;,tJ,. :1f\':i!,~.{:,if' Q" ty',> "~,:Cost",, ",i,lotal, '. '
~7'.~~",-,"..c,,"" '~~.:, :-l...~.._ci'#m!!.htttWl~~~&!l,:.t,t\~~~~ :'J;,.k~':" ~:!t~Tea';:~~&! fj%icost~~~.''',
First ADDliance $79,00 $
Furnace/burner including ducts and vents
Up to lOOk BTUlhr.
Over lOOk BTUlhr.
Heaters/stoves/vents
Unit heater
Wood/pellet/gas stove/flue
Repair/alter/add to heating appliance/
refrigeration unit or cooling system!
absorption system
Evaporated cooler
Vent fan with one duct/appliance vent
Hood with exhaust and duct
Floor furnace including vent
Gas piping
One to four outlets
$17,00 $
$20,00 $
$17.00 $
$38.00 $
$58,00 $
$13,00 $
$9.00 $
$13,00 $
$58.00 $
$7.00 $
$4,00 $
Additional outlets (each)
Air-handling units, including ducts
Up to 10,000 CFM I $11,00
Over 10,000 CFM I $20,00
Comnressor/absorotion svstem/heat pump
Up to 3 hp/100k BTU $17.00
Up to 15 hp/500k BTU $29,00
Up to 30 hp/1,OOO BTU $43,00
Up to 50 hp/I ,750 BTU $57.00
Over 50 hp/1,750 BTU $95,00
Incinerators
Domestic incinerator
$
$
$
$
$
$
$
I $20,00
$
F:;i.,
Ente: total v~luation o!~~anic~.tem
and installatIon costs $ ~ 7.-00 c
Enter fee based on valuation of mechanical system, etc. $
;;'""M:Y'~i!';!:;'~'f~I'I~~it';u.-~~j;t~~r::f~'i.-G:~4i';;~~;~~+\'&~][';2t!k O1"h~~ ;"iti1Cosf;<J" ;'~i Totah "
~>,}f.~JL!v'~~J?,.l!c~A~7~,~~~~:?!Tt~'~1?~ J!~m,~ ~f'~'tea'f~j~~Sj :~t'cost~.~~;
Reinspection $58.00 $
Specially requested inspections (per hr.) $58.00 $
Regulated equipment (unclassed) $13.00 $
Each additional inspection, (I) $58,00 $
!iifi"\"l'''';;;'''i.~~'~e'''''''.p). oO"-I""i."N-,.'~'U'S"'E"'''''''''')ji",~''J",,,,-,~,
"',.6~~~~i!i~;i~~' ,~W4r-J:/':'\I7(~;";;:vl:\ ,It\~.. _ _ P:~~};'f}7i!:1fR!11;'t~1!;l+;);;~~
(A) Enter subtotal of above fees (or enter set
-minimum-fee of $ 79.00)
(B) Investigative fee (equal to [A])
(C) Enter 12% surcharge (.12 x [A+B])
(D) Seismic fee, 1% (.01 x [A])
(E) Technology Fee (5% of [A])
TOT AL fees and surcharges (A through E),
$11~~
$
$ 11-/ I!!-
$
$ ~e--
$ n80&
COM check Software Version 3.8.1
Mechanical Compliance Certificate
2009 IECC
Section 1: Project Information
Project Type: Alteration
Project Tille: Springfield Utility Board
Construction Site:
202 South 18th Street
Springfield, OR 97477
Owner/Agent:
Springfield Utility Board Water Service
Center
202 South 18th Street
Sprinfield, OR 97477
541-744-3765
Designer/Contractor:
Dave English
Automatic Heat Company
3675 Franklin Blvd.
Eugene, OR 97403
541-726-7656
denglish@automaticheatco.com
Section 2: General Information
Building Location (for weather data):
Climate Zone:
Springfield, Oregon
4c
Section 3: Mechanical Systems List
Quantitv
1
System Tvee & DescriDtion
HVAC System 1 (Multiple-Zone) : Split System Heat Pump
Heating Mode: Capacity = 26 kBtu/h, Efficiency = 8.90 HSPF
Cooling Mode: Capacity = 23 kBtu/h, Efficiency = 18.00 SEER
6>"d~ tJ.-~ B.-iJ
Section 4: Requirements Checklist
"'" _Requirements Specific To: HVAC System 1 :
A1. Equipment minimum efficiency: Heat Pump: 7.7 HSPF 13.0 SEER
~2. Minimum one temperature control device per zone
~D 3. Systems serving more than one zone must be VAV systems
o 4. Controls capable of resetting supply air temp (SAT) by 25% of SAT-room temp difference
o Exception: Systems that prevent reheating, recooling or mixing of heated and cooled supply air
o Exception: Seventy five percent of the energy for reheating is from site-recovered or site solar energy sources.
o Exception: Zones with peak supply air quantities of 300 cfm (142 Us) or less.
/;fA
~Generic Requirements: Mustbe met by all systems to which the requirement is applicable:
? 1. Plant equipment and system capacity no greater than needed to meet loads
o Exception: Standby equipment automatically off when primary system is operating
)(2
~:
o Exception: Multiple units controlled to sequence operation as a function of load
Minimum one temperature control device. per system
Minimum one humidity control device per installed humidification/dehumidification system
Load calculations per ASHRAE/ACCA Standard 183
Automatic, Controls: Setback to 550F (heat} and 850F (cool): 7-c1ay clock, 2-hour occupant override, 10-hour backup
o Exception: Continuously operating zones
o Exception: 2 kW demand or less, submit calculations
Outside-air source for ventilation; system capable of reducing OSA to required minimum
R-5 supply and return air duct insulation in unconditioned spaces
pJko 6.
;Jo..-O 7.
Project Title: Springfield Utility Board
Data filename: C:\Users\Beau Pichel\Documents\COMcheck\sub water CtL dave eucck
Report date: 08/02/11
Page 1 of 5
R-B supply and return air duct insulation outside the building
R-B insulation between ducts and the building exterior when ducts are part of a building assembly
o Exception: Ducts located within equipment
o Exception: Ducts with interior and exterior temperature difference not exceeding 150F.
~8. Mechanical fasteners and sealants used to connect ducts and air distribution equipment
tv' ~ 0 9, Ducts sealed -longitudinal seams on rigid ducts; transverse seams on all ducts: UL 181A or 1818 tapes and mastics
.. Jt).... 0 10.Hot water pipe insulation: 1.5 in. for pipes <::=1.5 in. and 2 in. for pipes >1.5 in.
fV Chilled water/refrigerant/brine pipe insulation: 1.5 in. for pipes <=1.5 in. and 1.5 in. for pipes >1.5 in.
Steam pipe insulation: 1.5 in. for pipes <=1.5 in. and 3 in. for pipes >1.5 in.
o Exception: Piping within HVAC equipment.
o Exception: Fluid temperatures between 55 and 1050F.
o Exception: Fluid not heated or cooled with renewable energy.
o Exception: Piping within room fan-coil (with AHRI440 rating) and unit ventilators (with AHRI840 rating).
o Exception: Runouts <4 ft in length.
~ 11. Operation and maintenance manual provided to building owner
tv, li. 0 12.Balancing devices provided in accordance with IMC (2006) 603.17
fJ ft 0 13.oemand control ventilation (OCV) present for high design occupancy areas (>40 person/1 000 ft2 in spaces >500 ft2) and served by
systems with anyone of 1) an air-side economizer, 2) automatic modulating control of the outdoor air damper, or 3) a design outdoor
airflow greater than 3000 cfm.
o Exception: Systems with heat recovery.
o Exception: Multiple-zone systems without DOC of individual zones communicating with a central control panel.
o Exception: Systems with a design outdoor airflow less than 1200 cfm.
o Exception: Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm.
14.Motorized, automatic shutoff dampers required on exhaust and outdoor air supply openings
fJ1b
;J
D Exception: Gravity dampers acceptable in buildings <3 stories
o Exception: Gravity dampers acceptable in systems with outside or exhaust air flow rates less than 300 cfm where dampers are
interlocked with fan
~ 15.Automatic controls for freeze protection systems present
~ +6. Exhaust air heat recovery included for systems 5,000 cfm or greater with more than 70% outside air fraction or specifically exempted
o Exception: Hazardous exhaust systems, commercial kitchen and clothes dryer exhaust systems that the International Mechanical
Code prohibits the use of energy recovery systems.
o Exception: Systems serving spaces that are heated and not cooled to less than 60oF.
o Exception: Where more than 60 percent of the outdoor heating energy is provided from site-recovered or site solar energy.
o Exception: Heating systems in climates with less than 3600 HOD.
D Exception: Cooling systems in climates with a 1 percent cooling design wet-bulb temperature less than 640F.
o Exception: Systems requiring dehumidification that employ energy recovery in series with the cooling coil.
o Exception: Laboratory fume hood exhaust systems that have either a variable air volume system capable of reducing exhaust and
makeup air volume to 50 percent or less of design values or, a separate make up air supply meeting the following makeup air
requirements: a) at least 75 percent of exhaust flow rate, b) heated to no more than 20F below room setpoint temperature, c) cooled
to no lower than 30F above room setpoint temperature, d) no humidification added, e) no simultaneous heating and cooling.
Section 5: Compliance Statement
Compliance Statement: The proposed mechanical alteration project represented in this document is consistent with the building plans,
specifications and other calculations submitted with this permit application. The proposed mechanical alteration project has been designed
to meet the 2009 IECC, Chapter 8, requirements in COMcheck Version 3.8.1 and to comply with the man.datory requirements in the
Requirements Checklist.
-=e:e~tle E ~ tt ~ ~
~
ff 5-' II
Signature
Date
Project Notes:
Ductless Heat Pum System
Project Title: Springfield Utility Board
Data filename: C:\Users\Beau Pichel\Documents\COMcheck\sub water ctr. dave e..cck
Report date: 08/02/11
Page 2 of 5
SP=~N~~~
.~;- ~
,"7A OREGON
www.ci.springfield.or.us
TRANSACTION RECEIPT
811-5PR2011-01885
2025 18TH 5T
CITY OF SPRINGFIELD
225 Fifth 51
Springfield,OR 97477
541-726-3753
perrnitcenter@ci,springfield.or.us
RECEIPT NO: 2011002179 RECORD NO: 811-SPR2011-01885
tDES_CRI~TION'"-..,- '" 'c..' -- ;,,: ""f ,<y% 'c0'''i'-ACC.O,UIIlLC.ODE'''';--;:'
Mechanical Permit fee (based on value of work) 224-00000-425604
State of Ore90n Surcharge (12% of applicable fees) 821-00000-215004
Technology fee (5% of permit total) 100-00000-425605
TOTAL DUE:
E.J~",(MEN:U:Ye~~c:.:'E,o.y..OR" ,:C~SHIER7 CCI\~ENTER ~ COMMENTS' "''' :..:U., ,-, ..
Credit Card EUGENE HEATING INC
034236
DATE: 08/03/2011
AMOUNT..D,UE '
118.00
14.16
5.90
- - ..._-.._,.~.._-
138.06
'AMOUNTPAID~..~ ,,,.Ie ".....1
138.06
TOTAL PAID:
138.06