CITY OF SPRINGFIELD
Building I Commercial Permit
PERMIT NO: 811-SPR2011-01884
IVR Number: 811182726830
www_ci.springfield.or.us
225 Fifth St
Springfield,OR 97477
Phone: 541-726-3753
Inspection Phone: 541-726-3769
Fax: 541-726-3676
Issued
perm itcenler@ci.springfield.or.us
PROJECT STATUS:
STATUS DATE:
ISSUED:
APPLIED:
08/03/2011
08/03/2011
08/03/2011
SITE ADDRESS: 533 Q ST, Springfield, OR 97477
ASSES OR'S PARCEL NO: 1703264200604
EXPIRES:
VALUE:
01/29/2012
$0.00
SCOPE: Mechanical Only
WORK INVOLVED: Alteration
TYPE OF STRUCTURE: Commercial
PROJECT DESCRIPTION:
Replace rooftop air conditioner unit - wieght less than 200#
Phone Number: 541-741-1953
OWNER:
ADDRESS:
JENKINS FAMILY TRUST
PO BOX 920
SPRINGFIELD OR 97477
Contractor Type
Mechanical Contractor
CONTRACTOR INFORMATION ~
Lie Type
CCB
BUILDING INFORMATION ~
# of Stories:
Height of Structure:
Type of Heat:
Water Type:
Range Type:
Hazmat:
Contractor Name
EUGENE HEATING INC
# of Units:
o
# of Bedrooms:
Sprinkled Building:
Fire Alarms:
Energy Path:
Electrical Specialty Code Edition:
Springfield Fire Code Edition:
Mechanical Specialty Code Edition:
Municipal I Development Code:
Plumbing Specialty Code Edition:
Residential Specialty Code Edition:
Structural Specialty Code Edition:
lie No
188592
Lie Exp
11/05/2011
Phone
541-726-7656
Lot Size:
Sq Ft 1st Floor:
Sq Fl2nd Floor:
_.!~
Sq Ft Basement:
Sq Ft Garage:
Sq Ft Carport:
Sq F.tOther: '0 ' t
ATTt:, , I u,": uregon law requires you 0
foIJC'v9~'illI?'l,n~~b1'-~~<:I by the Oregon Utility
Notification Center. Those rules are set forth
in OAR 952-001-0010 through OAR 952-001-
00~~10 You may obtain copies of the rules by
calling the center. (Note: the telephone
number for the Oregon Utility Notification
Center is 1-800-332-2344).
Site Information
~
Engineered Fill:
Fill Volume:
Flood Hazard Area:
Land Hazard Area:
Retaining Wall:
Soils Report Required:
NOTICE: '. - .,.<<;.,? '"
TH IS PERMIT SHAll EXPIRE IF THE WORK
AUTHORIZED UNDER THIS PERMIT IS NOT
COMMENCED OR IS ABANDONED FOR
ANY 180 DAY PERIOD.
Springfield Building Permit
8/3/2011 1:31:17PM
Page 1 of 3
CITY OF SPRINGFIELD
Building I Commercial Permit
PERMIT NO: 811-SPR2011-01884
IVR Number: 811182726830
www.d.springfield.or.us
PROJECT STATUS:
STATUS DATE:
ISSUED:
APPLIED:
08/03/2011
08/03/2011
Issued
08/03/2011
225 Fifth SI
Springfield,OR 97477
Phone: 541.726.3753
Inspection Phone: 541.726.3769
Fax: 541.726.3676
permilcenter@ci.springfield.or.us
EXPIRES:
VALUE:
01/29/2012
$0.00
SITE ADDRESS: 533 Q ST. Springfield, OR 97477
ASSESOR'S PARCEL NO: 1703264200604
SCOPE: Mechanical Only
WORK INVOLVED: Alleration
TYPE OF STRUCTURE: Commercial
PROJECT DESCRIPTION:
Replace rooftop air conditioner unit - wieght less than 200#
DEVELOPMENT INFORMATION ~
Overlay Dist:
# Street Trees Reqd:
Paved Drive Reqd:
% of Lot Coverage:
Highest point on structure
to north property line:
Frontyard Setback:
Interior Setback:
Sideyard Setback:
Rearyard Setback:
Solar Setback:
REQUIRED PARKING
Total:
Handicapped:
Compact:
PUBLIC IMPROVEMENTS
~
Street Improvements:
Storm Sewer:
Storm Sewer Available:
Speciallnstructon:
Subdivision Accepted:
Notes:
Valuation Description
Description
Tvee of Construction
Unit Amount Unit Tvpe
Sidewalk Type:
DownspoutJDrains:
~
Unit Cost
Value
FEES PAID
~
OescriDtion
Amount Paid
Technology fee (5% of permit total) $5.41
Mechanical Permit !<<:e (based o~..':alue of ~,~~~.!.__.".___,_~_~~,,_,,~ 08.:~_~__"
State of Oregon Surcharge (12% of applicable fees) $12.99
Total Amount Paid $126.65
Date Paid
08/03/2011
08/03/2011
08/03/2011-- ..
ReciDt #
2011002178
2011002178
~'--'---'-"--._-
2011002178
Springfield Building Permit
8/3f2011 1:31:17PM
Page 2 of 3
SP~IN.G. FIE~.. .
~.".-
"'i' ifJ,
- J~' m OREGON
CITY OF SPRINGFIELD
Building I Commercial Permit
PERMIT NO: 811-SPR2011-01884
IVR Number: 811182726830
www.ci.springfield.or.us
225 Fifth SI
Springfield,OR 97477
Phone: 541-726-3753
Inspection Phone: 541-726-3769
Fax: 541-726-3676
permitcenter@ci,springfield.or.us
PROJECT STATUS:
STATUS DATE:
Issued
08/03/2011
ISSUED:
APPLIED:
08/03/2011
08/03/2011
EXPIRES:
VALUE:
01/29/2012
$0.00
SITE ADDRESS: 533 Q ST, Springfield, OR 97477
ASSES OR'S PARCEL NO: 1703264200604
SCOPE: Mechanical Only
WORK INVOLVED: Alteration
TYPE OF STRUCTURE: Commercial
PROJECT DESCRIPTION:
Replace rooftop air conditioner unit - wieght less than 200#
Plan Review
~
Oeoartment
Application Acceptance
Received Due Date Comoleted Result
08/03/2011 08/03/2011 08/03/2011 Over the Counter
Reviewer
Chris Carpenter
MeChanical Review 08/03/2011 06/03/2011 08/03/2011 Not Required Chris Carpenter
Comments: Over the counter permit
lt~itiaJReview; k;, i, ./:" ~'!,98/Q3!?P1t-<f, '9~/Q~/2Q1(' P8?9~!2,9f1!:~.~ 'Over the ~~~nter "igt;,phris,g.a~periter;;:
l Comments: 'OverthecounterRer;.nit~/':.> ~.'::~:;r~"~-'~P,' .,~: '''~ ~"$",~, f41~; _~:l:,0,t> :;' '.
__ _ ~~ _ _ ~ ~ _ _ :.-' :...,; ffiik~~::.~L:__L,..J,..\- h M"'- __--....- J"-""
INSPECTIONS REQUIRED ~
Inspections
2300 Rough Mechanical
2999 Final Mechanical
'~...,. . --'.'~-
Rough Mechanical: Prior to Cover
Final Mechanical: When all mechanical work is complete.
By signature, I state and agree, that I have carefully examined the completed application and do hereby certify that all
information ~ereon is true and correct, and I further certify that any and all work performed shall be done in accordance with the
Ordinances of the City of Springfield and the Laws of the State or Oregon pertaining to the work described herein, and that NO
OCCUPANCY will be made of any structure without permission of the Community Services Division, Building Safety. I further
certify that only contractors and employees who are in compliance with ORS 701.005 will be used on this project. I further agree
to ensure that all required inspections are requested at the proper time, that each address is readable from the street, that the
~::oo~~ '"" ~ ,~~" ro'"' "~u"'" 00 "" """, .",,""' 00""0
O.~'",'_", .;"","" 6-
Springfield Building Permit
8/3/2011 1:31:17PM
Page 3 of 3
Mechanical Permit Application
\.;;.&">.'1;;"j",-,:;,;.;;.o"" "'i.'{l}V'.'l;,.,':!'i"'''~,i'!::ii*;..Yi'',~ "\i'~h"t'\'ili",,~y,
"(~!,,;oEP ARTMEN'F.U5E'ONl.: Y"",:;'ii!
~;:~; t? 'J',,!,,;re.', ."U::,!,' ~:'" ,,:<,,~"r'~'i.;.~':':'i<i',,-":i::"-','~~~
225 Fifth Street. Springfield, OR 97477 . PH(541)726-3753 . FAX(541)726~3689
This permit is issued under OAR918-440-00S0. Permits expire if work is not started within 180 days of issuance or if work is
suspended for 180 days.
nR.~~~~)1~:S;~:~;~:.:C!S]~'G'q.f{Y2VQ~~'QQNstR@l9}J}~~;~;:~,f;~l_1;;~.iY': :~~ '~'.;f " ,., ", ...-? ..,'c' . (:',""'., FEE SCHEDULE ,',.'<: .".
, "
I 0 Government I mommercial :_,;"":'.:",;g..-',';:"J::':.",:'~";,.,,,i,,;,,,,'-~J;;,' .,. ''':''!.,,''' -~, Qtl';' ~~~~:~~i~ ~ii~~~~!i1~
0 Residential ~ResldentlaIGtf~~~~~r.'}7t?~~:i\'t.':/:\Y~g
~~".,;o.~">.,, ,,",UY:~-'''_'l,';);,:}'''i',-,<; C' ;fli~'~..~t~~..'~;,'rr'~,.-U;"..." t.,qi..,'V
~1~~:~;lrtj:Q!,!~~iiftErfiN'~QRn.if~illiQ~liA.Np?4f(;)~~;A,:i110i~fi;~;'~1;'i First Appliance $79.00 $
Job site address: ~-33 G( ~ h Furnace/burner including ducts and vents ,
City~tZ ) ""'1. Jfw_./;;f I State&Of\- I ZIP "/7t/?7 Up to 1 OOk BTUlhr. $17.00 $
Referen"ce: \' I \Y,:,' L\.o ~ I Taxlotfn". -'11 Over lOOk BTU/hr. $20.00 $
Heaters/stoves/vents
"'DESCRIP:TIC}!{'cjF WQRK";j', " .,'" .
Unit heater $17.00 $
M "...,,?, _/1 ./)J -i. ~.c..! r;P7/--4 Wood/pelleVgas stove/flue $38.00 $
, . , Repair/alter/add to heating appliance/
~~f~~~~~~1~lRR9J{~B_~~~~.WJ'~~~~~'?lI.~~'~~~~',~1f'~~ refrigeration unit or cooling system! $58.00 $
absorption system
Name; So dJtJV r' S / "H V~~ ~~r';l/';i F7I ~ Evaporated cooler $13.00 $
Address:S"'Y3 c:J;? S; t . PO$OIl "J2I:J 97'1~ 7 Vent fan with one duct/appliance vent $9.00 $
..5Pfc t:. {)-/2...
Sp,l.2.JY"; -I ~07'1 State: {/I- I ZIP4'79'77 Hood with exhaust and duct $13.00 $
City: Floor furnace including vent $58.00 $
Phone: - 7..v/~ /-"l $7 I Fax: - - Gas piping
E-mail: One to four outlets $7.00 $
This installation IS being made on property owned by me or a Additional outlets (each) $4.00 $
member of my immediate family, and IS exempt from licensing Air-handling units, including ducts
requirements under ORS 701.010. Up to 10,000 CFM I $11.00 $
Signature: Over 10,000 CFM $20.00 $
r~;\.i'~';\"-""~;fPV""~"w,,' kB)' . '-0-' "p;;;iNSJA""'~'-"'--'-"'--"'\~hff.\" :,~ yo r; ~~j\::((",'^;";:~ Com pressor/a bsorntion svstem/heat pump
;~'Y,,;,f~~~i.GJ~ N; "" A.GJL :J~'l ",~".L'_"J!J;AjIH~N_V't~Y:f>:~5,.~~$'i~"'t,,:!/2:
Business nameA IA. -fo YV\Lv--h; J / />-<;;rl CellI." ~, ~ I ,0/ ,Up to 3 hp/1 OOk BTU $17.00 $
Address: -?C,7<;- ?',l2An,e/J,,";8! jliJ Upto 15 hp/500k BTU $29,00 $
Up to 30 hp/l,OOO BTU $43.00 $
City: ?~A/Z I State~ I ZIP:C)7<1W3 Up to 50 hp/l,750 BTU $57.00 $
Phone: _I - I Fax: - - Over 50 hp/I,750 BTU $95.00 $
E-mail: .h/J ,'vA-Mi!EMom ll~r, ~ #<V/'Cv Incinerators
license n~.: /' cYS--S 7L Domestic incinerator ~20.00 $~
CCB
Print name: D~<<- t]eft,?L Enter total valuation of mechanical system
i?_ f0'J{;l and installation costs $ <{6oU -- -.
Signature: Enter fee based on valuation of mechanical system, etc. $
~M!~S~f!!Q~~Y~~:~~:~~~t~~~~I~;~ ~Y"\,'::Jl? ~4W~B~ti" ~~~~~t~~};~;:
Items
0#- c',':;''''',''''' ;.~~~~>;' ea:,~~;:_;:~
~( rJl \' WI A./ /q Reinspection . $58.00 $
---
Specially requested inspections (per hr.) $58.00 $
<Q)t ~ ~ f.ocJl,'b-- Regulated equipment (unclassed) $13.00 $
rL-r'l:Alf'lIN '7 - Each additional inspection: (1) $58.00 $
- i~~);<>j;;;"fnilf''''APFiIticAN;f.'{ji:JSE;,'''_''m~~''''~'~
!~,." 4-il~".,c\>" .~ - .ti~ ii:~, "_,,.'.' _. '%_. !~~~'B;~;" .:"1ih "",-,,!.1",t!1)111:6/tl;:i~
hi 9(fU~ - -
. --/1-<J ~ (A) Enter subtotal of above fees (or enter set $ //))\ 2."\
minimum fee of $ 79.00)
~
(B) Investigative fee (eq ual to [A]) $
(C) Enter 12% surcharge (.12 x [MB]) $ 17. q.'i
(0) Seismic fee, 1%(.01 x [A]) $
(E) Technology Fee (5% of [A]) $ S-~
440-2545-J (l1/08/COM) TOT AL rees ~nd surcharges (A through E): $ /U~5 I--
COMcheck Software Version 3.8.1
Mechanical Compliance Certificate
2009 IECC
Section 1: Project Information
Project Type: Alteration
Project Title: Air Conditioning Replacement
Construction Site:
533 Q Street
Springfield, OR 9.7477
Owner/Agent:
Pa!Jl.
Sonny's~Tav~'"!1
533 Q Street
Springfield, OR 97477
541-741-1953
Designer/Contractor:
Beau Pichel
Automatic Heat Company
3675 Franklin Blvd.
Eugene, OR 97403
541-726-7656
bpichel@automaticheatco.com
Section 2: General Information
Building Location (for weather data):
Climate Zone:
Springfield, Oregon
4c
Section 3: Mechanical Systems List
Quantitv
1
System Tvoe & Descriotion
HVAC System 1 (Single Zone) :
Cooling: 1 each - Split System, Capacity = 60 kBtu/h, Efficiency = 13.00 SEER, Air-Cooled Condenser, Air
Economizer
Section 4: Requirements Checklist
Requirements Specific To: HVAC System 1 :
~1. Equipment minimum efficiency: Split System: 13.0 SEER
~2." Cooling system provides a means to relieve excess outdoor air during economizer operation.
]LIC3. Integrated air economizer required
Generic Requirements: Must be met by all systems to which the requirement is applicable:
'J( 1. Plant equipment and system capacity no greater than needed to meet loads
o Exception: Standby equipment automatically off when primary system is operating
o Exception: Multiple units controlled to sequence operation as a function of load
~2. Minimum one temperature control device per system
~3. Minimum one humidity control device per installed humidification/dehumidification system
t!fA. Load calculations per ASHRAE/ACCA Standard 183
C)<5. Automatic Controls: Setback to 550F (heat) and 850F (cool); 7 -day clock, 2-hour occupant override, 1 O-hour backup
o Exception: Continuously operating zones
o Exception: 2 kW demand or less, submit calculations
)g" 6. Outside~air source for ventilation; system capable of reducing OS~ to required minimum
~ 7. R-5 supply and return air duct insulation in unconditioned spaces
R-8 supply and return air duct insulation outside the building
R-8 insulation between ducts and the building exterior when ducts are part of a building assembly
o Exception: Ducts located within equipment
~ 0 Exception: Ducts with interior and exterior temperature difference not exceeding 150F.
. )9, 8. Mechanical fasteners and sealants used to connect ducts and air distribution equipment
Project Title: Air Conditioning Replacement
Data filename: C:\Users\Beau Pichel\Documents\COMcheck\Sonny's Tavern.cck
Report date: 08/02/11
Page 1 of 4
~ 9. Ducts sealed - longitudinal seams on rigid ducts; transverse seams on all ducts; UL 181A or 181B tapes and mastics
o 10.Hot water pipe insulation: 1.5 in. for pipes <=1.5 in. and 2 in. for pipes >1.5 in.
Chilled water/refrigerant/brine pipe insulation: 1.5 in. for pipes <=1.5 in. and 1.5 in. for pipes >1.5 in.
t.l~ Steam pipe insulation: 1.5 in. for pipes <=1.5 in. and 3 in. for pipes >1.5 in.
o Exception: Piping within HVAC equipment.
o Exception: Fluid temperatures between 55 and 105cF.
o Exception: Fluid not heated or cooled with renewable energy.
o Exception: Piping within room fanMcoit (with AHRI440 rating) and unit ventilators (with AHRJ840 rating).
o Exception: Runouts <4 ft in length.
~ 11. Operation and maintenance manual provided to building owner
~ 12. Balancing devices provided in accordance with IMC (2006) 603.17
}'J 13. Demand control ventilation (DCV) present for high design occupancy areas (>40 person/1000 ft2 in spaces >500 ft2) and served by
systems with anyone of 1) an air-side economizer, 2) automatic modulating control of the outdoor air damper, or 3) a design outdoor
airflow greater than 3000 cfm.
o Exception: Systems with heat recovery.
o Exception: Multiple-zone systems without DOC of individual zones communicating with a central control panel.
o Exception: Systems with a design outdoor airflow less than 1200 cfm.
. 0 Exception: Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm.
A 14.Motorized, automatic shutoff dampers required on exhaust and outdoor air supply openings
o Exception: Gravity dampers acceptable in buildings <3 stories
o Exception: Gravity dampers acceptable in systems with outside or exhaust air flow rates less than 300 cfm where dampers are
interlocked with fan
~ 15.Automatic controls for freeze protection systems present
')? 16. Exhaust air heat recovery included for systems 5,000 cfm or greater with more than 70% outside air fraction or specifically exempted
o Exception: Hazardous exhaust systems, commercial kitchen and clothes dryer exhaust systems that the International Mechanical
Code prohibits the use of energy recovery systems.
o Exception: Systems serving spaces that are heated and not cooled to less than 60oF.
o Exception: Where more than 60 percent of the outdoor heating energy is provided from site-recovered or site solar energy.
o Exception: Heating systems in climates with less than 3600 HOD.
D Exception: Cooling systems in climates with a 1 percent cooling design wet~bulb temperature less than 640F.
D Exception: Systems requiring dehumidification that employ energy recovery in series with the cooling coil.
D Exception: Laboratory fume hood exhaust systems that have either a variable air volume system capable of reducing exhaust and
makeup air volume to 50 percent or less of design values or, a separate make up air supply meeting the ~o\\owing makeup air
requirements: a) at least 75 percent of exhaust flow rate, b) heated to no more than 20F below room setpoint temperature, c) cooled
to no lower than 30F above room setpoint temperature, d) no humidification added, e) no simultaneous heating and cooling.
Section 5: Compliance Statement
Compliance Statement: The proposed mechanical alteration project represented in this document is consistent with the building plans,
specifications and other calculations submitted with this permit application. The proposed mechanical alteration project has been designed
to meet the 2009 IECC, Chapter 8, requirements in COMcheck Version 3.8.1 and to comply with the mandatory requirements in the
R~::tSR:~k;:\ &f>wa~7L ~eu
Name - Title Signature ~~
Project Title: Air Conditioning Replacement
Data filename: C:\Users\Beau Pichel\Documents\COMcheck\Sonny's Tavern.cck
Report date: 08/02/11
Page 2 of 4
Custom proposal for:
, Automatic
Heat Company
Sonny's Tavern
533 Q Street
Springfield, Oregnn 97477
541-741-1953
July 22, 2011
3675 Franklin Blvd Eugene Or. 97403
Better Business Bureau
CCB# 188592
Air Conditionin2: unit replacement
~utomatic Heat ~ropos.est~ f~rnish all ma!erials an.dperfonn .t~'~ lalJor to complete the following;
~ Remove the existing rooftop air conditioning unit and recycle it in a safe environmentally
manner.
~ Supply and install a new Goodman 5 ton roof top air conditioning unit.
~ Supply and install a new 5 ton horizontal air conditioning coil on your existing air handler.
~ Replace the refrigerant lines with a new line set using Puron, R-410A environmentally safe
refrigerant.
~ Supply the code required seismic attachments to the roof.
~ Provide all needed mechanical and electrical permits with the City of Springfield.
~ Provide Automatic Heat's lifetime warranty on all of Automatic Heat's workmanship.
~ Provide system startup and customer walk through.
~ Provide electrical runs to new air conditioner (208, single phase), including a 110-voIt gfi protected
service outlet at the outdoor air conditioner (performed by GMD Electric CCB# 162191.
Goodman 5 ton air conditioning unit 5,200.00
Labor, materials (5% discount for cash -$260.00) Included
Total Investment $4.940.00
Warranty:
'. '<::9mpressor 5 -Years - Parts 2 - Year~. Labnr 2 -Years
Automatic Heat Company is hereby authorized to furnish all materials and labor required to complete the work specified in
the above proposal. I agree to pay the amount specified above, according to the terms of this contract. The above prices,
specificatinns and cnnditinns are satisfactnry and are hereby accepted. Ynu are aulhnrized to. do. the wnrk as specified.
Payments will be made as outlined above. Any alteration or deviation from above specifications involving extra costs will be
executed only upon written order, and will become an extra charge over and above the estimate. All agreements contingent
upon strikes, accidents or delays beyond our control. ~rQPosal pr.!p~.!.e<J~y__~~a~ .ri~h~1501_-712~~
- - _..- -
Accepted by
Date
Aooroved orice
2
WWN.cLspringfield .or. us
TRANSACTION RECEIPT
811-SPR2011-01884
533 Q ST
CITY OF SPRINGFIELD
225 Fifth St
Springfield, OR 97477
541-726-3753
perm itcenler@ci.springfield.or.us
RECEIPT NO: 2011002178 RECORD NO: 811.SPR2011.01884 DATE: 08/03/2011
!DESCRIP.JIOIII~::""".~:':___':_~.""" ";' ~i...."\__ACCOUNT.CODE .~AMQUNTdDUE;$. ~; " ]
._Jy1echanica.!.!:'~,,:,!!.I~.,: (based on val".e.?1 work)__._._.._ ____.2.24.~000~4.2~6.0~_.___ 108.25
_~tate 01 O~~"rcha~g.:~% 01 applicable lee~ 821-00000.21~~0~___ _ _ _ _____ 12.99
Technology lee (5% 01 permit total) 100-00000.425605 5.41
TOTAL DUE: 126.65
COMMENtS';"-"~ ;"1- :.:_~~;I'PAID.;....';_'-'~
126.65
W~YME!;lTTYPE
Credit Card
033206
\:::: ....:.::::: ...... ". - ..:.~ ::.,:.:::::. .::........... '>;::'. ...,;~.:: ': ::" ..:. .~.<::.:..'Y
. P....YOR '-. CASg'ER:_CCARPENTEf.:~:'" ",
EUGENE HEATING INC
TOTAL PAID:
126.65