HomeMy WebLinkAboutPermit Correspondence 2001-4-30 ~ ., ~ Ie. G~ver Engi.eerin~.c. 1050 Bethel Dr. Suite # D 4 'Eugene, Oregon 97402 (541) 688-3020 "'*' ~;"~ April 30, 2001 , ,J Dukes & Dukes Construction P.O. Box 71095 Eugene, OR 97401 Re: ;3516 Ambleside Drive. Sorirndield Job #01076 As you requested, an inspections of the Post-Tensioned slab installation were performed at the above noted location. During those inspections the following observations were made. An inspection of the tendon layout was performe<i on Aprilll, 2001. A total of 15 tendons had been installed, with a total length of 417 feet as per tendon placement plan. The tendons were installed by Post Tension of Oregon. All tendons were installed according to allowable tolerances noted on the plans to pass around plumbing and electrical stub outs required in the slab. , An inspection of the tendon tensioning was performed on April 18, 2001, after the concrete had reached the required 2000 psi for tensioning. The tendons were stressed to ajacking force of33 kips, with a pump gauge reading of5500 psi. See attached monostrand tendon stressing record provided by Post Tension of Oregon dated 4/18/01 for measured tendon elongations. The serial number of the jack used for stressing is # 1 028, and the gauge is #PTO 1. The tendon mill test certificate #V3238 shows that the tendons have a modulus of elasticity of28800 ksi. The calculated and measured elongation for all of the installed tendons was within the acceptable deviation range of + or - 10%. The installed and elongated tendons meet the calculated design requirements of the post-tension slab and the tendon ends may be cut. Thank you for this opportunity to be of service. If you have any further questions please contact me at (541) 688-3020. Very truly yours, Owen Grover, P.E. ( .. I .._-~, POST TENSION OF OREGON P.O. BOX 26423 EUGENE, OREGON. 97402 MONOSTRAND STRESSING RECORD Page of Project Name: AMBLESIDE MEADOWS LOT 128, Site Address: 3516 AMBLESIDE SPRINGFIELD, OREGON Project # 01-8 Date: 4/18/01 Weather: SUNNY I Geneml Contractor: DUKES & DUKES CONSTRUCTION Floor # Pour # Jack Serial # 1028 PTOl Stressed by : JOHN GOULD Verified: KEVINPJ:H~ON Gauge Serial # Date of Drawing: Special Remarks: Tendon Jacking Gauge Calc. Measured Elongation % No. Location Force Reading Elong. End 1 End 2 Total Deviation Al 33 Kips 5500 1 7/8 1 3/4 1 3/4 6.67% A2 33 Kips 5500 1 7/8 1 7/8 1 7/8 0.00% A3 33 Kips 5500 1 7/8 1 7/8 1 7/8 0.00% A4 33 Kips 5500 1 7/8 1 3/4 1 3/4 6.67% AS 33 Kips 5500 1 7/8 1 7/8 1 7/8 0.00% A6 33 Kips 55001 1 7/8 I 7/8 1 7/8 I 0.00% A7 33 Kips 55001 1 7/8 1 3/4 1 3/4 6.67% A8 33 Kips 55001 1 7/8 1 3/4 1 3/4 6.67% Bl 33 Kips 55001 2 3/8 2 1/4 2 1/4 5.26% B2 33 Kips 55001 2 3/8 2 3/8 2 3/8 0.00% B3 33 Kips 55001 2 3/8 2 1/4 2 1/4 5.26% B4 33 Kips 55001 2 3/8 2 3/8 2 3/8 0,00% B5 33 Kips 55001 2 3/8 2 1/2 2 1/2 -5.26% B6 33 Kips 55001 2 3/8 2 3/8 2 3/8 0.00% B7 33 Kips 55001 2 3/8 2 3/8 2 3/8 0.00% 33 Kips 1 33 Kips I 33 Kips I 33 Kips -I 33.Kips 33 Kips 33 Kips 33 Kips 33 Kips 33 Kips 33 Kips 33 Kips 33 Kips 33 Kips ' 33 Kips i 33 Kips I 33 Kips I 33 Kips I 33 Kips I 33 Kips I I .~' ~i. : ~_~~, ,..,._.t: ~. .~ SUMIOEN WIRE PROOUlL II ~ CORPORATION 13290 SABRE BLVD. VICTORVILLE, CA 92394 PHONE: (760) 246-6091 . FAX (760) 246-3023 ~WPC ". ~** MILL CERTIfICATE OF INSPECTION *** PAGE 1 OF ORDER NUMBER : V3238 ISSUE DATE : 03/16/01 -----------.--~-.--__.__________________.__~___u__________________.___._~____ COI'1I'10DI TY STEEL STRAND. UNCOATED SEVEN-WIRE FOR PRESTRESSED CONCRETE ASTM A416 / Grade 270 Size 1/2 Low Relaxation (Minilax) SPECIFICATIOI'I ------------.-------------------------------------------------------- CUSTOMER POST TENSION OF NEVADA. INC P.O. NUMBER : 1716 STATE .JOI3 NO MANUFACTURER : Sumiden Wire Product Corporation DESTINATION : HENDERSON NV -------------...----_____.___.________w.____________________________._____._.__ ------------------------------------.-----------.----.---.-----.-------...- PACK NUMBER CERTIFIED: 1'10. PACK,l:t- H E A T-tf 8.S EL CURVE# ( 1 b) ( :(; ) ELASTIC Y.P AREA MODULUS (lb) (sq.in.) (m psi) -------------.------------------.-.------------------------------------- 1 V19693, V2GF633 43,076 6.0 V19694 39,37'2 0.1529 28.8 2 . Y19694 V2GF6;:S3 42,796 5.7 '.119694 39,372 o . 1529 28.8' 61 "".se. YL ....-.. .-. . _3 V19695 V2GF6,33 42,700 c' .::. V19694- 39,372 O. 1529 28.8 . ..). D 4 V19696 V2GF633 42,767 5.7 V.1.9694 39,372 0.1529 28.8 5 II 19697- V2GF633, 42,562 5.7 V19694 39,372 0.1529 28.8 6 '119698 \!2~;F633 .::12,689 5.7 V19698 39.445 O. J 530 28.7 7 Vf9700 V2Gf:"633 42,751 5.7 \i 19698 39,445 O. 1530 28.7 8 .V19701": V2GFG33 42,692 5.8 V19698 39,445 0.1530 28.7 ---------------.---______________________M__________________________-___ 'Stress-strain curves attached represent a pack from the same t.wenty tOil production lo.t as the cettified pacl<;_.ASHij A416.' We hereby certify that: ___'.___ * We have accurately carried out the inspection of commodity as described aboya: in accordance with all applicable specifications 01' t.hl:'! cOill,rac't. ,:p; The rn"d',el"la,l descr.ibed a:bo\l:;3 i~J:i.ll bond to concrete of C\ nOt"mal strenqth 2n~ 8onsistency.in conformance with the prediction eql.l,'-\t.,:i.OIi':':' 'i'Oj" i:,t",,,.nsfet" 'a;ld development leil2th given in the ACI/AASHTO specifications. ~:~:;~~~;-~;~, i~~--