Loading...
HomeMy WebLinkAboutPermit Building 2002-5-10 Job# 02-00350-01 Page 1 of 5 225 Fifth Street Springfield, OR 97477 RESIDENTIAL PERMIT City Of Springfield Community Services Division Building Safety Job Number: 02-00350-01 Office: 726-3759 Inspection Line: 726-3769 Location Of Proposed Site: 6719 Aaron Ln Spr Assessors Map#: 17023411 Lot: 98 Block: Addition: 2nd Owner: Address: Tax Lot #: 13200 Subdivision: Levi Landing Tom Wirfs Enterprises Inc Po Box 237 Phone Number: 541-747-8704 City/State/Zip: Springfield, OR 97477 New Value: $164,389 Scope Of Work: Single Family Residence SFR same as 6695 Jacob Lane with bonus room finished Contractor Type Contractor Registration # Expiration Date Phone General Contr Tom Wirfs Enterprises Inc 32947 6/28/2004 541-747-8704 Po Box 237, Springfield, OR 97477 Electrical Contr Bills Electric 21351 4/28/2002 541-687-1851 3170 West 11th Street, Eugene, OR Mechanical Contr Home Comfort Heating & Air Conditioning 184164 6/25/2003 541-345-2838 Po Box 24205, Eugene, OR 97402 Plumbing Contr Home Comfort Heating & Air Conditioning 184164 6/25/2003 541-345-2838 Po Box 24205, Eugene, OR 97402 Quad Area: # Of Units: Constr. Type: Water Heater: 4RNE 1 (VN) Wood Frame Gas Office Use Land Use: Single Family Dwelling Zoning Code: LDR Bedrooms: 3 Range: Gas # Of Buildings: 1 Occupancy Group: Dwelling Heat Source: Forced Air Gas Sq. Footage: 2088 To request an inspection call the 24 hour recording at 726-3769. All inspections requested before 7:00 a.m. will be made the same working day, inspections requested after 7:00 a.m. will be made the following working day. Site Verify Ground Rod Footing Foundation Post and Beam Floor Insulation Ceiling Insulation Shear Wall Nailing Framing Required Inspections I Building I - To be made after excavation but prior to setting forms. -Install ground rod at footing, and call for inspection in conjuction with footing and/or foundation ir -After trenches are excavated. -After forms are erected but prior to concrete placement. ' - Prior to floor insulation or decking. - Prior to decking. - Prior to cover. - Before covering sheathing with finish materials. - Prior to cover. Wall Insulation Drywall Final Building Temporary Power Verify Ground Rod Rough Electrical Electrical Service Final Electrical Underfloor Plumbing Underfloor Drain Rough Plumbing Water Line Sanitary Sewer Line Storm Sewer Line Final Plumbing Underfloor Mechanical Rough Gas Rough Mechanical Gas Service Final Gas Final Mechanical SW-Curbside CC-Standard Street Improvement: Curb Cut?~ San Sewer Depth (Ft): Storm Sewer Available? Special Req.: Security Required: Bond Begin DateTime: Special Instructions: Other Utilities: Project Supervisor: Job# 02-00350-01 Required Inspections Buildin~ Page 2 of 5 - Prior to Cover - Prior to taping. - When all required inspections have been approved and the building is complete. I Electrical I -Approval required prior to SUB energizing pole. ,-Install ground rod at footing, and call for inspection in conjuction with footing andlor foundation ir - Prior to cover. -Must be approved to obtain permanent power. - When all electrical work is complete. I Plumbing -Prior to insulation or decking. - Prior to cover or placement of concrete. - Prior to cover. -Prior to filling trench. - Prior to filling trench. - Prior to filling trench. -When all plumbing work is complete. I Mechanical - Prior to insulation or decking'. ~After line is installed and capped if not attached to an appliance. - Prior to cover. -After line is installed and line has been connected to a minimum of one appliance. Pressure tes -When all gas work is complete. -When all mechanical work is complete. I Public Works J -After forms are erected but prior to placement of concrete -After forms are erected but prior to placement of concrete Fully Improved Improvement Agr.?D 6 4 D Sidewalk Type: Additional ROW? Size Of Line (in): DownspoutslDrains: Enchroachment Permit: San Sewer Tee (in): Bond End DateTime: 0010010000 00:00:00 ' Curbside - 5' D 8 To Curb and Gutter 4 0010010000 00:00:00 . Types Of Warning Devices Reqd. Job# 02-00350-01 Zoning: LDR FloodPlain? 0 Wetlands? 0 Journal numbers 1: 1997-06-0142 2: 2002-03-0093 3: Comments:City Engineer determined floodplain - FEMA Elevation Cert. Require( Overlay District: Floodplain Overlay # of Street Trees: 2 Page 3 of 5 Land Use: Single Family Dwelling Pave Driveway? 0 ' Additional Requirements: LDAP Required Glenwood Area? 0 Required Attachments: Source Locn: Material: Planner: Urban Growth Boundary?D Quantity Of Fill: Supplier: Drainage: Floodway FEMA: See Above Construction Types:(VN) Wood Frame Occupancy Groups: Dwelling # Of Buildings: 1 # Of Bedrooms: 3 Handicap Access? 0 -Area (Sq. Feet) Main: 2088 Accessory:440 Fee Same As Plan Review Hourly Plan Review Total Plan Check Building Permit State Surcharge For Building Permit 8% Building Administrative Fee Total Building Minimum Electrical Permit Fee Wiring Footage 1,000 Sq Ft or Less Wiring Footage Each Add'l 500 Sq Ft Temporary: 200 Amps or Less State Surcharge - Electrical 8% Admin Fee - Electrical Total Electrical Minimum Plumbing Permit Fee Two Bathrooms State Surcharge - Plumbing 8% Administrative Fee - Plumbing Total Plumbing Hood and Exhaust One to Four Outlets Minimum Mechanical Permit 8% Administrative Fee - Mechanical Less than 100,000 BTU Flood Plain FEMA: Private Garage/Carp/Stor # Of Stories: 2 Height (feet): 23 Current Units: Proposed Units:1 Census Code: New SF - detached Total:2528 Paid On Receipt# Plan Check 03/28/2002 8434 05/10/2002 8962 Building 05/10/2002 8962 05/10/2002 8962 05/10/2002 8962 Electrical 05/10/2002 8962 05/10/2002 8962 05/10/2002 8962 05/10/2002 8962 05/10/2002 8962 05/10/2002 8962 Plumbing 05/10/2002 8962 05/10/2002 8962 05/10/2002 8962 05/10/2002 8962 Mechanical 05/10/2002 8962 05/10/2002 8962 05/10/2002 8962 05/10/2002 8962 05/10/2002 8962 Value/Quantity Fee Amount 1 5 $100,00 $202.50 $302.50 164,389 $776.90 $54.38 $62.15 $893.43 1 4 1 $.00 $106.00 $76.00 $50.00 $16,24 $18.56 $266.80 $.00 $254.00 $17.78 $20.32 $292.10 1 1 $9,00 $4.00 $.00 $5.36 $12.00 Fee Vent Fan to One Duct ApplianceVent (Not Covered in Schedule Gas Fireplace Dryer Vent Mechanical Issuance State Surcharge - Mechanical Total Mechanical New Sidewalk New Curbcut Multiple Permit Discount - 2nd Permit Total Public Works Residential - Single Family - Storm Residential Improvement MWMC MWMC Administrative Fee SDC Administrative Fee Residential Sanitary MWMC Residential - Improvement Residential - Reimbursement Sanitary Sewer SDC Reimbursement Sanitary Sewer SDC Improvement Total System Development S.F. Residence - Willamalane Total Willamalane SDC , Planning Plan Review Total Planning Address Assignment Total Permits w/o Srchg Grand Total Plan Check Type Checked By Initial Review-Res Lisa Hopper Bob Kettwig Liz Miller Engineering-Res Planning-Res Structural-Res Don Moore job# 02-00350-01 Paid On Receipt# Mechanical 05/10/2002 8962 05/10/2002 8962 05/10/2002 8962 05/10/2002 8962 05/10/2002 8962 05/10/2002 8962 Public Works 05/10/2002 8962 05/10/2002 8962 05/10/2002 8962 , , I System Development 05/10/2002 8962 05/10/2002 ,,8962 05/10/2002 8962 05/10/2002 ' 8962 05/10/2002 8962 05/10/2002 8962 05/10/2002 8962 05/10/2002 8962 05/10/2002 8962 Willamalane SDC I 05/10/2002 8962 Planning 05/10/2002 8962 Permits w/o Srchg 05/10/2002 8962 Date Completed Comment 04/02/2002 04/10/2002 04/07/2002 Page 4 of 5 Value/Quantity Fee Amount 3 $18.00 1 $9.00 1 $9.00 1 $6.00 $10.00 $4.69 $87.05 50 $75.00 1 $75.00 1 $-30.00 $120.00 3,666 '$1,000.68 1 $34.83 1 $10.00 , $149.15 1 $332.86 1 $659.76 1 $155.13 21 $448.77 21 $341.04 $3,132.22 1 $1,000.00 $1,000.00 1 $55.00 $55.00 1 $8.00 $8.00 $6,157.10 Needs to pick up LDAP. FEMA Elevation Cert. Required. 04/17/2002 Job# 02-00350-01 Page 5 of 5 By signature, I state and agree, that I have carefully examined the completed application and do hereby certify that all information hereon is true and correct, and I further certify that any and all work performed shall be done in accordance with the Ordinances of the City bf Springfield and the Laws of the State of Oregon pertaining to the work described herein, and that NO OCCUPANCY will be made of any structure without permission of the Community Services Division, Building Safety. I further certify that only contractors and employees who are in compliance with ORS 701.055 will be used on this project. I further agree to ensure that all required inspections are requested at the proper time, that each address is readable from the street, that the permit card is located at the front of the property, and the approved set of plans will remain on the site at all times during construction. Signature Date