Loading...
HomeMy WebLinkAboutPermit Building 2002-5-17 . I Job# 02-00352-01 ( Page 1 of 5 SPRINGFIELD ~. 225 Fifth Street Springfield, OR 97477 RESIDENTIAL PERMIT City Of Springfield Community Services Division' Building Safety Job Number: 02-00352-01 Office: 726-3759 Inspection Line: 726-3769 Location Of Proposed Site: 6687 Aaron Ln Spr Assessors Map#: 17023411 Lot: 95 Block: Addition: 2nd Tax Lot #: 12900 Subdivision: Levi Landing Owner: Tom Wirfs Enterprises Inc Po Box 237 Phone Number: 541-747-8704 City/State/Zip: Springfield, OR 97477 New Value: $134,847 Address: Scope Of Work: Single Family Residence SFR (Not) same as 6695 Jacob Ln except NO bonus room Contractor Type Contractor Registration # Expiration Date Phone General Contr -...... . Tom Wirfs Enterprises Inc "'~" 32947 6/28/2004 541-747-8704 Po Box 237, Springfield, OR 97477 Electrical Contr Bills Electric 21351 4/28/2002 ' 541-687-1851 3170 West 11th Street, Eugene, OR Mechanical Contr Home Comfort Heating & Air Conditioning 184164 6/25/2003 541-345-2838 Po Box 24205, Eugene, OR 97402 Plumbing Contr Home Comfort Heating & Air Conditioning 184164 6/25/2003 541-345-2838 Po Box 24205, Eugene, OR 97402 Office Use Land Use: Single Family Dwelling Zoning Code: LDR Bedrooms: 3 Range: Gas Quad Area: # Of Units: Constr. Type: Water Heater: 4RNE 1 (VN) Wood Frame Gas # Of Buildings: 1 Occupancy Group: Dwelling Heat Source: Forced Air Gas Sq. Footage: 1466 To request an inspection call the 24 hour recording at 726-3769. All inspections requested before 7:00 a.m. will be made the same working day, inspections requested after 7:00 a.m. will be made the following working day. Site Verify Ground Rod Footing Foundation Post and Beam Floor Insulation Ceiling Insulation Shear Wall Nailing Framing Required Inspections I Building I - To be made after excavation but prior to setting forms. -Install ground rod at footing, and call for inspection in conjuction with footing and/or foundation ir -After trenches are excavated. -After forms are erected but prior to concrete placement. -Prior to floor insulation or decking. -Prior to decking. - Prior to cover. - Before covering sheathing with finish materials. - Prior to cover. Wall Insulation Drywall Final Building Temporary Power Verify Ground Rod Rough Electrical Electrical Service Final Electrical Underfloor Plumbing Underfloor Drain Rough Plumbing Water Line Sanitary Sewer Line Storm Sewer Line Final Plumbing Underfloor Mechanical Rough Gas Rough Mechanical Gas Service Final Gas Final Mechanical SW-Curbside CC-Standard Street Improvement: Curb Cut?0 San Sewer Depth (Ft): Storm Sewer Available? Special Req.: Security Required: Bond Begin DateTime: Special Instructions: Other Utilities: Project Supervisor: -I . Job# 02-00352-01 Page 2 of 5 Required Inspections Building - Prior to Cover -Prior to taping. - When all required inspections have been approved and the building is complete. I Electrical I -Approval required prior to SUB energizing pole. -Install ground rod at footing, and call for inspection in conjuction with footing andlor foundation ir - Prior to cover. -Must be approved to obtain permanent power. - When all electrical work is complete. I Plumbing - Prior to insulation or decking. - Prior to cover or placement of concrete. - Prior to cover. -Prior to filling trench. -Prior to filling trench. - Prior to filling trench, -When all plumbing work is complete. I Mechanical -Prior to insulation or decking. -After line is installed and capped if not attached to an appliance. - Prior to cover. -After line is installed and line has been connected to a minimum of one appliance. Pressure tes - When all gas work is complete. - When all mechanical work is complete. I Public Works I -After forms are erected but prior to placement of concrete -After forms are erected but prior to placement of concrete Fully Improved Improvement Agr.?D 6 4 D Sidewalk Type: Curbside - 5' Additional ROW? 0 Size Of Line (in): 8 Downspouts/Drains: To Curb and Gutter Enchroachment Permit: San Sewer Tee (in): Bond End DateTime: 0010010000 00:00:00 ' 001001000000:00:00 ' Types Of Warning Devices Reqd. .1 Job# 02-00352-01 Page 3 of 5 land Use: Single Family Dwelling Pave Driveway? ~ Overlay District: Floodplain Overlay # of Street Trees: 2 Zoning: LDR FloodPlain? ~ Wetlands? D Journal numbers 1: 1997-06-0142 2: 2002-03-0092 3: Comments:City Engineer Determined Floodplain- FEMA Elevation Cert. Require Additional Requirements: LDAP Required Glenwood Area? D Required Attachments: Source locn: Material: Planner: Urban Growth Boundary?D Quantity Of Fill: Supplier: Drainage: Floodway FEMA: See Above Construction Types:(VN) Wood Frame Occupancy Groups: Dwelling # Of Buildings: 1 # Of Bedrooms: 3 Handicap Access? D -Area (Sq. Feet) Main: 1466 Accessory:420 Fee Residential Plan Check Same As Plan Review Additional Plan Check Hourly Plan Review Total Plan Check Building Permit State Surcharge For Building Permit 8% Building Administrative Fee Total Building Minimum Electrical Permit Fee Wiring Footage 1,000 Sq Ft or Less Wiring Footage Each Add'l 500 Sq Ft Temporary: 200 Amps or Less State Surcharge - Electrical 8% Admin Fee - Electrical Total Electrical Minimum Plumbing Permit Fee Two Bathrooms State Surcharge - Plumbing 8% Administrative Fee - Plumbing Total Plumbing Hood and Exhaust One to Four Outlets Minimum Mechanical Permit Flood Plain FEMA: Private Garage/Carp/Stor # Of Stories: 2 Height (feet): 23 Current Units: Proposed Units:1 Census Code: New SF - detached Total:1886 Paid On Receipt# Plan Check 05/13/2002 8982 03/28/2002 8436 Value/Quantity Fee Amount 134,847 1 $441.61 $100.00 $.00 $45.00 $586.61 Building 134,847 $679.40 $47.56 $54.35 $781.31 Electrical 1 3 1 $.00 $106.00 $57.00 $50.00 $14.91 $17.04 $244.95 I I Plumbing $.00 $254,00 $17.78 $20.32 $292.10 Mechanical 1 1 $9.00 $4.00 $.00 '1 Fee 8% Administrative Fee - Mechanical Less than 100,000 BTU Vent Fan to One Duct . ApplianceVent (Not Covered in Schedule Gas Fireplace Dryer Vent Mechanical Issuance State Surcharge - Mechanical Total Mechanical New Sidewalk New Curbcut Multiple Permit Discount - 2nd Permit Total Public Works Residential - Single Family - Storm Residential Improvement MWMC MWMC Administrative Fee SDC Administrative Fee Residential Sanitary MWMC Residential - Improvement Residential - Reimbursement Sanitary Sewer SDC Reimbursement Sanitary Sewer SDC Improvement Total System Development S.F. Residence - Wi llama lane Total Willamalane SDC Planning Plan Review Total Planning Address Assignment Total Permits w/o Srchg Grand Total Plan Check Type Checked By Initial Review-Res Lisa Hopper Bob Kettwig Liz Miller Engineering-Res Planning-Res Job# 02-00352-01 Page 4 of 5 Paid On Receipt# Mechanical Value/Quantity 1 3 1 1 1 Public Works 60 1 1 System Development 2,586 1 1 1 1 1 21 21 Willamalane SDC 1 Planning Permits w/o Srchg 1 Date Completed Comment 04/02/2002 04/05/2002 04/05/2002 Fee Amount $5.36 $12,00 $18.00 $9.00 $9.00 $6.00 $10.00 $4.69 $87.05 $75.00 $75.00 $-30.00 $120.00 $705.95 $34.83 $10.00 $134.42 $332.86 $659.76 $155.13 $448.77 $341.04 $2,822.76 $1,000.00 $1,000.00 $55.00 $55.00 $8.00 $8.00 $5,997.78 Needs to pick up LDAP. FEMA Elevation- Certificate Required. Survey letter enclosed regarding minimum setbacks. '1 Job# 02-00352-01 I Date Completed Page 5 of 5 Plan Check Type Checked By Comment Structural-Res Don Moore 04/09/2002 NOT SAME-AS Needs to resubmit plans with a recognizable scale, and consistent dimensions. Need complete roof framing plan and truss manufacturer's layout drawing. Drawings must be consistent with each other. Must pay regular plan review fee with revised submittal. Applicant advised by letter 4/9/02 - dim Structural-Res Don Moore 05/17/2002 Applicant notified of requirements for accurate plans. Plans inadequate Structural-Res Tom Marx 05/14/2002 By signature, I state and agree, that I have carefully examined the completed application and do hereby certify that all information hereon is true and correct, and I further certify that any and all work performed shall be done in accordance with the Ordinances of the City of Springfield and the Laws of the State of Oregon pertaining to the work described herein, and that NO OCCUPANCY will be made of any structure without permission of the Community Services Division, Building Safety. I further certify that only contractors and employees who are in compliance with ORS 701.055 will be used on this project. I further agree to ensure that all required inspections are requested at the proper time, that each address is readable from the street, that the permit card is located at the front of the property, and the approved set of plans will remain on the site at all times during construction. Signature Date