HomeMy WebLinkAboutPermit Building 2002-6-25
'(
.
I
"
~
",
Job# 02-00626-01
Page 1 of 5
225 Fifth Street
Springfield, OR 97477
CITY OF 'SPRINGFIELD, OREGON
TRANS#;Ol-0009725
DATE;JUN 25 2002
AMT RECD;2 $ 5800=40
CHANGE:
CFiSHIER; 003
RESIDENTIAL PERMIT
City Of Springfield
Community Services Division
Building Safety
Job Number: 02-00626-01
Office: 726-3759
Inspection Line: 726-3769
Location Of Proposed Site: 6684 Aaron Ln Spr
Assessors Map#: 17023411
Lot: 106 Block: Addition: 2nd
Owner:
Address:
Tax Lot #: 14000
Subdivision: Levi Landing
Bobby Wilson
4950 Forsythia Street
Phone Number: 541-988-0363
City/State/Zip: Springfield, OR 97478
New Value: $158,608
Scope Of Work: Single Family Residence
Contractor Type
General Contr
Electrical Contr
Mechanical Contr
Plumbing Contr
Quad Area:
# Of Units:
Constr. Type:
Water Heater:
Contractor
Pacific Homes ,,'0',,- "
3923 Jasper Rd, Springfield, OR 97478
Lynns Electric Co
Po Box A, Fall Creek, OR 97438
'" .' -eqUlres you tV
ATTENTiO!\!:0(~gcd"~'~_~~~ Oregon Utility
R ' ... t .t., "....to#ad'E"\01E': t'i D t se~p'ti"vth
egIs ralon' . xplrauge I <.8 e are lone
. 14". tion Centei. ! II ' -- - AR 01=\2-001-
9176771ca .~12' 00i4h1Q/Q@.@:'4)ugh 0 5~ 1"- Z!46-3025
in OAR 95 - . 'v .: co ies of the rUles uy
0090. You may ob~a'7NO~: the te\epho~e
1 023u.€)lIing the c9'O& W28R~tility Not5~~1:tl726-7895
number for the. ir aYOO-332-2344).
Center IS -
133733 2/23/2003 541-767 -0626
Dean Heating and Air
4301 Main, Springfield, OR 97478
Rs Plumbing Contractor Inc 103816 1/4/2004 541-461-4714
2234 Dakota St, Eugene, OR 97402-1018 Not'~~:. ~UL\' \ EXPIRE IF THE ~ORK .
Office Use lU~tiO~i:O UNDER lHIS PEK~~lfa~'OT
Land Use: Single Family Dtti'lllMEWAtU Ejitl~~N~ON
Zoning Code: LOR Ait'l180 Q~~~\ll!1Q3-roup: Dwelling
Bedrooms: 3 ." Heat Source: Forced Air Electric
Range: Gas Sq. Footage: 2000
4RNE
1
(VN) Wood Frame
Gas
To request an inspection call the 24 hour recording at 726-3769. All inspections requested before 7:00
a.m. will be made the same working day, inspections requested after 7:00 a.m. will be made the following
working day.
Site
Footing
Foundation
Post and Beam
Floor Insulation
Ceiling Insulation
Shear Wall Nailing
Framing
Wall Insulation
Required Inspections
I Building I
- To be made after excavation but prior to setting forms.
-After trenches are excavated.
-After forms are erected but prior to concrete placement.
-Prior to floor insulation or decking.
-Prior to decking.
- Prior to cover.
-Before covering sheathing with finish materials.
- Prior to cover.
- Prior to Cover
Street Improvement: Fully Improved
Curb Cut?0 Improvement Agr.?D
San Sewer Depth (Ft): 6 4
Storm Sewer Available? D
Special Req.:
Security Required:
Bond Begin DateTime: 00/00/0000 00:00:00 .
Special Instructions:
Other Utilities:
Project Supervisor:
Drywall
Final Building
Temporary Power
Verify Ground Rod
Rough Electrical
Electrical Service
Final Electrical
Underfloor Plumbing
Underfloor Drain
Rough Plumbing
Water Line
Sanitary Sewer Line
Storm Sewer Line
Final Plumbing
Underfloor Mechanical
Rough Gas
Rough Mechanical
Gas Service
Final Gas
Final Mechanical
SW-Curbside
CC-Standard
Job# 02-00626-01
Required Inspections
Building
Page 2 of 5
-Prior to taping.
- When all required inspections have been approved and the building is complete.
I Electrical I
-Approval required prior to SUB energizing pole.
-Install ground rod at footing, and call for inspection in conjuction with footing and/or foundation ir
- Prior to cover.
-Must be approved to obtain permanent power.
- When all electrical work is complete.
I Plumbing
-Prior to insulation or decking.
- Prior to cover or placement of concrete.
- Prior to cover.
-Prior to filling trench.
-Prior to filling trenc~. .
-Prior to filling trench. .
-When all plumbing work is complete.
I Mechanical
- Prior to insulation or decking.
-After line is installed and capped if not attached to an appliance.
- Prior to cover.
-After line is installed and line has been connected to a minimum of one appliance. Pressure tes
-When all gas work is complete.
-When all mechanical work is complete.
I Public Works I
-After forms are erected but prior to placement of concrete
-After forms are erected but prior to placement of concrete
Sidewalk Type:
Additional ROW?
Size Of Line (in):
Downspouts/Drains:
Enchroachment Permit:
San Sewer Tee (in):
Bond End DateTime:
Curbside - 5'
D
8
To Curb and Gutter
6
00/00/000000:00:00 .
Types Of Warning Devices Reqd.
I Job#02-00626-01 I
Page 3 of 5
Land Use: Single Family Dwelling
Pave Driveway? 0
Zoning: LOR
FloodPlain? 0 Wetlands? D
Journal numbers
1: 1997-06-0142 2: 3:
Comments:Subdivision/City Engineer determined flood plain
Overlay District: Floodplain Overlay
# of Street Trees: 2
Additional Requirements: LDAP Required
Glenwood Area? D Required Attachments:
Source Locn:
Material:
Planner:
Urban Growth Boundary?D
Quantity Of Fill:
Supplier:
Drainage:
Floodway FEMA: see Above
Construction Types:(VN) Wood Frame
Occupancy Groups: Dwelling
# Of Buildings: 1
# Of Bedrooms: 3
Handicap Access? D
-Area (Sq. Feet)
Main: 2000 Accessory:480
Fee
Residential Plan Check
Total Plan Check
Building Permit
State Surcharge For Building Permit
8% Building Administrative Fee
Total Building
Minimum Electrical Permit Fee
Wiring Footage 1,000 Sq Ft or Less
Wiring Footage Each Add'l 500 Sq Ft
Temporary: 200 Amps or Less
State Surcharge - Electrical
8% Admin Fee - Electrical
Total Electrical
Minimum Plumbing Permit Fee
Two Bathrooms
State Surcharge - Plumbing
8% Administrative Fee - Plumbing
Total Plumbing
Hood and Exhaust
One to Four Outlets
Minimum Mechanical Permit
8% Administrative Fee - Mechanical
Less than 100,000 BTU
Vent Fan to One Duct
Flood Plain FEMA:
Private Garage/Carp/Stor
# Of Stories: 2 Height (feet): 22
Current Units: . Proposed Units:1
Census Code: New SF - detached
Total:2480
Paid On Receipt#
Plan Check
OS/28/2002 9266
Value/Quantity
Fee Amount
158,608
$492.31
$492.31
Building
06/25/2002 9725
06/25/2002 9725
06/25/2002 9725
158,608
$757.40
$53.02
$60.59
$871.01
Electrical
06/25/2002 9725
06/25/2002 9725
06/25/2002 9725
06/25/2002 9725
06/25/2002 9725
06/25/2002 9725
1
3
1
$.00
$106.00
$57.00
$50.00
$14.91
$17.04
$244.95
Plumbing
06/25/2002 9725
06/25/2002 9725
06/25/2002 9725
06/25/2002 9725
1
$.00
$254.00
$17.78
$20.32
$292.10
Mechanical
06/25/2002 9725
06/25/2002 9725
06/25/2002 9725
06/25/2002 9725
06/25/2002 9725
06/25/2002 9725
1
1
$9.00
$4.00
$.00
$5.36
$12.00
$18.00
1
3
Fee
ApplianceVent (Not Covered in Schedule
Gas Fireplace
Dryer Vent
Mechanical Issuance
State Surcharge - Mechanical
Total Mechanical
New Sidewalk
New Curbcut
Multiple Permit Discount - 2nd Permit
Total Public Works
Residential - Single Family - Storm
Residential Improvement MWMC
MWMC Administrative Fee
SDC Administrative Fee
Residential Sanitary MWMC
Residential - Improvement
Residential - Reimbursement
Sanitary Sewer SDC Reimbursement
Sanitary Sewer SDC Improvement
Total System Development
S.F. Residence - Willamalane
Total Willamalane SDC
Planning Plan Review
Total Planning
Address Assignment
Total Permits w/o Srchg
Grand Total
Plan Check Type
Checked By
Initial Review-Res
Lisa Hopper
Denny Wright
Liz Miller
Engineering-Res
Planning-Res
Structural-Res
Don Moore
Job# 02-00626-01 I
Paid On Receipt#
Mechanical
06/25/2002 9725
06/25/2002 9725
06/25/2002 9725
06/25/2002 9725
06/25/2002 9725
Public Works
06/25/2002 9725
06/25/2002 9725
06/25/2002 9725
System Development
06i25/2002 9725
06/25/2002 9725
06/25/2002 9725
06/25/2002 9725
06/25/2002 9725
06/25/2002 9725
06/25/2002 9725
06/25/2002 9725
06/25/2002 9725
Willamalane SDC
06/25/2002 9725
Planning
06/25/2002 9725
Permits w/o Srchg
06/25/2002 9725
Date Completed
Comment
OS/29/2002
06/08/2002
06/07/2002
Page 4 of 5
Value/Quantity Fee Amount
1
1
1
50
1
1
2,942
1
1
1
1
1
26
26
1
1
j
1
$9.00
$9.00
$6.00
$10.00
$4.69
$87.05
$75.00
$75.00
$-30.00
$120.00
$803.17
$34.83
$10.00
$148.68
$332.86
$659.76
$155.13
$555.62
$422.24
$3,122.29
$1,000.00
$1,000.00
$55.00
$55.00
$8.00
$8.00
$6,292,71
Needs to pick up LDAP. Currently processing.
Enclosed letter regarding survey of minimum
setbacks. FEMA elevation certificate required.
06/11/2002
"Job# 02-00626-01 Page 5 of 5
By signature, I state and agree, that I have carefully examined the completed application and do
hereby certify that all information hereon is true and correct, and I further certify that any and all work
performed shall be done in accordance with the Ordinances of the City of Springfield and the Laws of
the State of Oregon pertaining to the work described herein, and that NO OCCUPANCY will be made
of any structure without permission of the Community Services Division, Building Safety. I further
certify that only contractors and employees who are in compliance with ORS 701.055 will be used on
this project.
I further agree to ensure that all required inspections are requested at the proper time, that each
adcj,ress is readable from the street, that the permit card is located at the front of the property, and the
ap proved set of plans will reJ)ain on the site at all times during construction. ,
(1. (;( tA!fJr: ?;1, !f jJk ~ -$ 4:r
St6nature C Date
...
, I
CJ)
. '
:. .....-0..::.
TOTAL
I
6lL\4 . ctc=)
, :-;.
CITY OF SPRINGFIELD SYSTEMS DEVELOPMENT CHARGE WORKSHEET
JOURNAL OR JOB NUMBER: 02-00626-01
NAME OR COMPANY: Bobby Wilson
LOCATION: 6684 Aaron Ln.
TAX LOT NUMBER: 17-02-34-11 Tax Lot # 14000
DEVELOPMENT TYPE: SINGLE F AMIL Y RESIDENCE
NEW DWELLING UNITS: 1 Bl)ILDING SIZE: 2172
1. STORM DRAINAGE
DIRECT RUNOFF TO CITY STORM SYSTEM
IMPERVIOUS S.F. COST PER S.F.
x
2942.00 $0.273
RUNOFF ROUTED TO DRYWELL DESIGNED AND CONSTRUCTED TO CITY STANDARDS
IMPERVIOUS S.F. COST PER S.F. DISCOUNT RATE
x x
0.00 $0.273 50%
I ITEM 1 TOTAL - STORM DRAINAGE SDC
2. SANITARY SEWER - CITY
A. REIMBURSEMENT COST:
NUMBER OF DFU's COST PER DFU
;,.
26 $21.37
B. IMPROVEMENT COST:
NUMBER OF DFU's I COST PER DFU
x
26 I $16.24
I ITEM 2 TOTAL - CITY SANITARY SEWER SDC
3. TRANSPORTATION
A. REIMBURSEMENT COST:
ADT TRIP RATE NUMBER OF UNITS
x
9.57 1
B. IMPROVEMENT COST:
ADT TRIP RATE NUMBER OF UNITS II COST PER TRIP
x x x
9.57 1 1 $68.94
I ITEM 3 TOTAL - TRANSPORTATION SDC
:l. SANITARY SEWER - MWMC
A. REIMBURSEMENT COST:
NUMBER OF FEU's COST PER FEU
x
1 $332.86
B. IMPROVEMENT COST:
NUMBER OF FEU's I COST PER FEU
x
1 I $34.83
MWMC CREDIT IF APPLICABLE (SEE REVERSE)
SUBTOTAL OF MWMC REIMBURSEMENT, IMPROVEMENT & CREDIT
MWMC ADMINISTRATIVE FEE
, ITEM 4 TOTAL - MWMC SANITARY SEWER SDC
I SUBTOTAL (ADD ITEMS 1,2,3, & 4)
5. ADMINISTRATIVE FEE:
SUBTOTAL ADM. FEE RATE
x
$2,973.61
Steve Templin
SDC COORDINATOR
SF
LOT SIZE:
x
COST PER TRIP
, $16.21
x
NEW TRIP FACTOR
1.00 =,
NEW TRIP FACTOR
1.00 =1
=1
5%
6/8/2002
TOTAL SDC CHARGES =
DATE
6099
r:/)
~
o
o
u
~
~
r--
r:/)
~
d
~
SF
=,
$803.17
'=1
=1
$0.00
$803.17
1070
=1
$555.62
1091
=1
=,
$422.24 I 11092
$977.86~
$155.13
1093
$659.76
$814.89
1094
=1
$332.86
=1 $34.83 I
=1 $0.00 ,
=1 $367.69 , 1055
=, $10.00 I 1056
=f $377.69 , I
=1$2,973.61 I II
=1
$148.68
1073
$3,122.29
....
DRAINAGE FIXTURE UNIT (DFU) CALCULATION TABLE
NUMBER OF NEW FIXTURES x UNIT EQUIVALENT = DRAINAGE FIXTURE UNITS
(NOTE: FOR REMODELS, CALCULATE ONLY THE NET ADDITIONAL FIXTURES)
NO. OF FIXTURES DRAINAGE
( # NEW # OLD ) UNIT FIXTURE
- x EQUIVALENT = UNITS
(3 O)x 3 9
(0 O)x 1 0
( OO)x 3 0
(0 O)x 3 0
(0 O)x 6 0
(0 O)x 2 0
(1 O)x 3 3
(0 O)x 6 0
(0 0) x 12 0
(0 O)x 1 0
(0 O)x 3 0
(0 O)x 2 0
(0 O)x 2 0
(1 O)x 3 3
(0 O)x 2 0
(0 O)x 1 0
(0 O)x 2 0
(2 O)x 1 2
(0 O)x 5 0
(0 O)x 6 0
(3 '0) x 3 9
FIXTURE TYPE
BATHTUB
DRINKING,FOUNT AIN
FLOOR DRAIN
INTERCEPTORS FOR GREASE / OIL / SOLIDS / ETC.
INTERCEPTORS FOR SAND / AUTO WASH / ETC.
LAUNDRY TUB
CLOTHESW ASHER / MOP SINK
CLOTHESW ASHER - 3 OR MORE (EA)
MOBILE HOME PARK TRAP (1 PER TRAILER)
RECEPTOR FOR REFRIG / WATER STATION / ETC.
RECEPTOR FOR COM. SINK / DISHWASHER / ETC.
SHOWER, SINGLE STALL
SHOWER, GANG (NUMBER OF HEADS)
SINK: COMMERCIAL/RESIDENTIAL KITCHEN
SINK: COMMERCIAL BAR
SINK: DOMESTIC BAR
WASH BASIN
LAVATORY
URINAL, STALL/WALL
TOILET, PUBLIC INSTALLATION
TOILET, PRIVATE INSTALLATION
MISCELLANEOUS DFU TYPE NUMBER OF EDU's*
(0 0) x 20 0
TOTAL DRAINAGE FIXTURE UNITS =, 26
*EDU (Equivalent Dwelling Unit) is a discharge equivalent to a single family dwelling unit (20 DFU's) set at 167 gallons per day
MWMC CREDIT CALCULATION TABLE: BASED ON COUNTY ASSESSED VALUE
IF IMPROVEMENTS OCCURRED AFTER ANNEXATION DATE, CALCULATE CREDIT SEP ARA TEL Y
YEAR CREDIT RATE PER $1,000 YEAR CREDIT RATE PER $1,000
ANNEXED ASSESSED VALUE ANNEXED ASSESSED VALUE
1979 OR BEFORE $4.92 1990 $2,06
1980 $4,83 199 I $1.64
198\ $4,77 \992 $1.45
1982 $4.64 1993 $1.31 '
1983 $4.47 1994 $1.13
1984 $4.30 1995 $0,97
1985 $4.09 1996 $0.82
1986 $3,78 ]997 $0,63
1987 $3.4 I 1998 $0.4\
1988 $2.98 1999 $0,22
1989 $2,52 2000 $0,04
VALUE / 1000 CREDIT RATE
0.000 X $0.04 =1
0.000 X $0.04 =,
TOTAL MWMC CREDIT =1
CREDIT FOR LAND (IF APPLICABLE)
CREDIT FOR IMPROVEMENT (IF AFTER ANNEXATION)
$0.00
$0.00
$0.00
~
225 5tn STREET, SPRINGFIELD, OR 97477
SPRINGFIELD ~'\""''''jij
~
(541)726.3753
FAX(541) 726.3676
Estimated Base Flood Elevation & Disclaimer
The calculated Base Flood Elevation (BFE) for 10t#M, Levi Landing-
Second Addition is 5"'/0', 9 feet above mean sea level, based on the current
FEMA datum information. The floor level of the residence to be placed on
the lot must be certified at least one foot above the Base Flood Elevation as
indicated above. (Please note - the City's surveyed benchmark datum information and
the FEMA benchmark datum are not the same for this area. Add 0.30jt to the City's
benchmarks to adjust to the FEMA benchmark elevations. )
The estimated base flood elevations in this area are based on interpretation
of scientific and engineering evaluations known to the city at this time.
Larger floods can and will occur on rare occasions. Flood heights may be
increased by human-made or natural causes. The City's estimation of a
base flood elevation does not imply that land within this area will be free
from flooding or flood damages or that confonnance with the requirements
of the City will protect the property from flooding or flood damages.
The City, its officers, agents and employees shall not be liable for any flood
damage that may result from estimation of base flood elevation or any other
administrative decision made regarding administration of the City's
Floodplain Development Code. The developer of this property may elect to
perfonn additional scientific and engineering studies for consideration by
the City to further refine the estimated base flood elevation for this property.
The developer of this property may also elect to undertake additional
development and construction measures in addition to those re.quired in
article 27 of the Springfield Development Code designed to avoid or
minimize-the potential forflood hazards and damage. Such additional
measures are subject to City approval.
Acknowledgment:
I hereby acknowledge receipt of a copy of this document:
Name (PrinttLad;t, IAJif-G .
SignatureWl~ >4- {1 lis< Date -.Ie -;)~~--OY
(This copy to be signed by O~ner's ~[fagent and retained in City address file)