Loading...
HomeMy WebLinkAboutPermit Building 1996-1-26 Page 1 RESIDENTIAL PERMIT APPLICATION CITY OF SPRINGFIELD COMMUNITY SERVICES DIVISION BUILDING SAFETY Job Number: 960073 225 North Fifth Street Springfield, OR 97477 Office: 726-3759 Inspection Line: 726-3769 Location of Proposed Work: 929 RIVER KNOLL WAY Assessors Map #: 17032300 Lot: 38 Block: Tax Lot #: 01003 Subdivision: RIVER GLEN Owner: HOMEBLDRS/.u>uAE B Phone #: 485-3176 Address: 3593 RIVER POINTE DRIVECity/State/Zip: EUGENE, OREGON 97408 Describe Work: S.F. RESIDENCE NEW Contractor Canst. Contractor # Expires Phone General: FUTURE B 0036499 3593 River pointe Dr Eugene OR 9740 05/18/96 485-3176 QUM MEA: 2IDW # OF UNITS: 1 CONSTR. TYPE: VN SECONDMY HEAT: FP INSUL PATH: PI OFFICE USE -- LAND USE: 1111 ZONING CODE: LDR # OF BDRMS: 4 WATER HEATER: G SQ FOOTAGE: 2590 # OF BLDGS: 1 OCCY GROUP: R3 HEAT SOURCE: FG RANGE: G To request an inspection, call the 24 hour recording at 726-3769. All inspections requested before 7:00 a,m, will be made the same working day, inspections requested after 7:00 a,m, will be made the following work day. REQUIRED INSPECTIONS --- FOOTING - After trenches are excavated, FOUNDATION - After forms are erected but prior to concrete placement. UNDERFLOOR PLUMBING - Prior to insulation or decking, UNDERFLOOR MECHANICAL - Prior to insulation or decking. POST AND BEAM - Prior to floor insulation or decking. INSULATION - Floor; prior to decking Wall/Ceiling; Prior to cover SANITARY SEWER LINE - Prior to filling trench, STORM SEWER LINE - Prior to filling trench. WATER LINE - Prior to filling trench. ROUGH PLUMBING - Prior to cover. ROUGH MECHANICAL - Prior to cover. ROUGH ELECTRICAL - Prior to cover. ELECTRICAL SERVICE - Must be approved to obtain permanent power. ROUGH GAS - after line is installed and capped if not attached to an appliance GAS SERVICE - After line is installed and line has been connected to a minimum of one appliance. Pressure test done at this point. FRAMING - Prior to cover. INSULATION - Floor; prior to decking Wall/Ceiling; Prior to cover DRYWALL - Prior to taping. FINAL PLUMBING - When all plumbing work is complete. FINAL MECHANICAL - When all mechanical work is complete, FINAL ELECTRICAL - When all electrical work is complete, FINAL BUILDING - When all required inspections have been approved and the building is complete. Lot Faces: N Setbk From NPL: 50 Topography: 2 Solar Approved: Y Total Height: 30 Lot Type: INTERIOR SPRINGFIELD ~*' Job Number: 960073 Page 2 House Garage N 44 35 Setbacks S W 5 E 12 Item Main Garage Total Value BUILDING PERMIT Square Feet x 2161 484 $/Square Feet 56,2 14.1 Value 121,448,00 6,824,00 128,272.00 Building Permit Fee Surcharge/Admin 498,25 39,86 TOTAL FEE (A) 538.11 --- SYSTEMS DEVELOPMENT CHARGE (SDC) --- (B) 2,892.15 Systems Development Charge is due on all undeveloped properties within the City limits and the Citys Urban Growth Boundry which are being improved, PLUMBING PERMIT --- Item Residential Bath(s) 3 Fee 192,50 Plumbing Permit Surcharge/Admin 192.50 15,41 TOTAL CHARGE (C) 207.91 - - - MECHANICAL PERMIT - - - Furnace Exhaust Hood Vent Fan Dryer Vent IN LIEU ASSMT WILLAMALANE SDC PLAN REVIEW FEE 4 6.00 4.50 0.00 3,00 5,00 4.50 0.00 Mechanical Permit Issuance Surcharge/Admin 23,00 10,00 1. 84 TOTAL PERMIT (D) 34..84 --- MISCELLANEOUS PERMITS --- Surcharge/Admin Sidewalk Curb Cut WILLAMALANE SDC PLAN REVIEW FEE 0.00 16,30 13,30 1,000,00 323,86 TOTAL MISCELLANEOUS PERMITS (E) 1,353.46 (Excluding Electrical) unless otherwise noted TOTAL AMOUNT DUE (A, B, C, D, and E combined) 5,026.47 --- BUILDING VALUE, PLAN CHECK AND BUILDING PERMIT --- This permit is granted on the express condition that the said construction shall, in all respects, conform to the Ordinance adopted by the City of Springfield, including the Development Code, regulating the construction and use of buildings, and may be suspended or revoked at any time upon violation of any provisions of said ordinances. Job Number: 960073 Page 3 Received By: Plans Reviewed By: DON MOORE Date: 01/25/96 Building Site Reviewed By: LISA HOPPER --- ADDITIONAL COMMENTS --- STRUCTURE CANNOT EXCEED 30 FEET IN HEIGHT. VERBAL AGREEMENT MADE WITH JERRY/FUTURE B ON HEIGHT ALTER PATH 1; SEPARATE ELECTRICAL PERMIT IS REQUIRED. DRIVEWAY REQUIRED TO BE PAVED 1 STREET TREES REQUIRED By signature, I state and agree, that I have carefully examined the completed application and do hereby certify that all information hereon is true and correct, and I further certify that any and all work performed shall be done in accordance with the Ordinances of the City of Springfield, and the Laws of the State of Oregon pertaining to the work described herein, and that NO OCCUPANCY will be made of any structure without permission of the Community Services Division, Building Safety. I further certify that only contractors and employees who are in compliance with ORS 701.055 will be used on this project. I further agree to ensure that all required inspections are requested at the proper time, that each address is readable from the street, that the permit card is located at the front of the property, and the approved set of plans will r~main on the site at all times during construction. ; ;< f\ Q ~ ~,.J~_~ Sig'nAture( " I ~ \j'LS /q~ Dat'e VALIDATION --- Receipt Number: --2L;1/'9Y Date Paid: /-~ '% Amount Received: ""'A26. V? Received By: - ~ ..