HomeMy WebLinkAboutPermit Building 1996-8-22 SPAINQFIELD RESIDENTIAL PERMIT APPLICATION CITY OF SPRINGFIELD COMMUNITY SERVICES DIVISION BUILDING SAFETY Page 1 Job Number: 961124 225 North Fifth Street Springfield, OR 97477 q:l'i ~ RIVER Office: 726-3759 Inspection Line: 726-3769 Location of Proposed Work: Assessors Map #: 17032300 Lot: 41 Block: KNOLL WAY Tax Lot #: 01003 Subdivision: RIVER GLEN Owner: FUTURE B HOMES Phone #: 485-3176 Address: 3593 RIVER POINTE DRIVECity/State/Zip: EUGENE, OREGON 97408 Describe Work: S.F. RESIDENCE NEW Const. Contractor Contractor # Expires Phone General: FUTURE B HOMES 0036499 05/18/97 485-3176 3593 River Pointe Dr Eugene OR 9740 Plumbing: CUSTOM PLUMBING 0081994 05/06/97 485-1146 3248 Kentwood Dr Eugene OR 97401000 Mechanical: ROLFS HEATING 0102455 10/04/96 686-4927 PO Box 66 Dexter OR 974310000 Electrical: BOB FISHER 0096275 01/25/97 689-7973 180 Kingsbury Ave Eugene OR 9740400 QUAD AREA: 2RNW # OF UNITS: 1 CONSTR, TYPE: VN SECONDARY HEAT: FP INSUL PATH: PI OFFICE USE -- LAND USE: 1111 ZONING CODE: LDR # OF BDRMS: 3 WATER HEATER: G SQ FOOTAGE: 2496 # OF BLDGS: 1 OCCY GROUP: R3 HEAT SOURCE: FG RANGE: E To request an inspection, call the 24 hour recording at 726-3769. All inspections requested before 7:00 a.m. will be made the same working day, inspections requested after 7:00 a,m. will be made the following work day, REQUIRED INSPECTIONS ___ FOOTING - After trenches are excavated. FOUNDATION - After forms are erected but prior to concrete placement, UNDERFLOOR PLUMBING - Prior to insulation or decking, UNDERFLOOR,MECHANICAL - Prior to insulation or decking, ROUGH GAS - after line is installed and capped if not attached to an appliance POST AND BEAM - Prior to floor insulation or decking. INSULATION - Floor; prior to decking wall/Ceiling; Prior to cover STORM SEWER LINE - Prior to filling trench, SANITARY SEWER LINE - Prior to filling trench, WATER LINE - Prior to filling trench. ROUGH PLUMBING - Prior to cover. ROUGH MECHANICAL - Prior to cover, ROUGH ELECTRICAL - Prior to cover. ELECTRICAL SERVICE - Must be approved to obtain permanent power. FRAMING - Prior to cover, INSULATION - Floor; prior to decking Wall/Ceiling; Prior to cover DRYWALL - Prior to taping. SIDEWALK - After excavation is complete; forms and sub-base material in place. CURB COT - After forms are erected but prior to placement of concrete. GAS SERVICE - After line is installed and line has been connected to a minimum of one appliance. Pressure test done at this point. Job Number: 961124 FINAL PLUMBING - When all plumbing work is complete. FINAL MECHANICAL - When all mechanical work is complete, FINAL ELECTRICAL - When all electrical work is complete, FENCE - After fence is constructed. BACKFLOW DEVICE - After device is installed but before backfilling trench, FINAL BUILDING - When all required inspections have been approved and the building is complete. Lot Faces: S Topography: 2 Solar Approved: Y Lot Sq. Ft.: 6450 Total Height: 24 Lot Type: INTERIOR Setbacks S W E 8 Page 2 Lot Coverage: 30 % Setbk From NPL: 48 N House 23 Garage 18 6 Item Main Garage Total Value BUILDING PERMIT --- Square Feet x 1997 496 $/Square Feet 64,66 16.27 Building Permit Fee Surcharge/Admin TOTAL FEE (A) --- SYSTEMS DEVELOPMENT CHARGE (SDC) ___ Value 129,126,00 8,070.00 137,196.00 518,50 41.49 559.99 (B) 2,826.47 Systems Development Charge is due on all undeveloped properties within the City limits and the Citys Urban Growth Boundry which are being improved, PLUMBING PERMIT --- Item Residential Bath(s) BACKFLOW DEVICE 3 Plumbing Permit Surcharge/Admin TOTAL CHARGE (C) --- MECHANICAL PERMIT --- Furnace Exhaust Hood Vent Fan Dryer Vent GAS PIPING & F,P, 4 Mechanical Permit Issuance SurCharge/Admin TOTAL PERMIT (D) --- MISCELLANEOUS PERMITS --- Surcharge/Admin Sidewalk Curb Cut Fee 192.50 10,00 202.50 16.21 218.71 12,00 4.50 12,00 3,00 6.50 38,00 10,00 3.04 51. 04 0,00 16,75 14,80 SPRINGFIELD Job Number: 961124 Page 3 PLAN CHECK FEE WILLAMALANE SDC ELECTRICAL PERMIT FENCE I':>DO 00 160,00 1,000.00 183.60 5.00 TOTAL MISCELLANEOUS PERMITS (E) 1,380.15 (Excluding Electrical) unless otherwise noted TOTAL AMOUNT DUE (A, B, C, D, and E combined) 5,036.36 --- BUILDING VALUE, PLAN CHECK AND BUILDING PERMIT ___ This permit is granted on the express condition that the said construction shall, in all respects, conform to the Ordinance adopted by the City of Springfield, including the Development Code, regulating the construction and use of buildings, and may be suspended or revoked at any time upon violation of any provisions of said ordinances. Received By: Plans Reviewed By: DON MOORE Date: 08/22/96 Building Site Reviewed By: LISA HOPPER -- - ADDITIONAL COMMENTS --- PATH 1 DRIVEWAY REQUIRED TO BE PAVED 2 STREET TREES REQUIRED By signsture, I state and agree, that I have carefully examined the completed application and do hereby certify that all information hereon is true and correct, and I further certify that any and all work performed shall be done in accordance with the Ordinances of the City of Springfield, and the Laws of the State of Oregon pertaining to the work described herein, and that NO OCCUPANCY will be made of any structure without permission of the Community Services Division, Building Safety. I further certify that only contractors and employees who are in compliance with ORS 701.055 will be used on this project. I further agree to ensure that all required inspections are requested at the proper time, that each address is readable from the street, that the permit card is located at the front of the property, and the approved set of plans will remain on the site at all times during construction. ~~..~~~~"-- f~~tO G ~~/22/~ SPRINGFIELD Job Number: 961124 Receipt Number: Date Paid: Amount Received: Received By: --- VALIDATION 211 r;, <6 9;, 22-q C C)/) ~( /J , ~ L-. ; - 1M, Page 4