HomeMy WebLinkAboutPermit Building 1998-8-19
.- '
'.
~PRINGFIELD
Page 1
RESIDENTIAL PERMIT APPLICATION
CITY OF SPRINGFIELD
COMMUNITY SERVICES DIVISION
BUILDING SAFETY
Job Number: 980968
225 North Fifth Street
Springfield, OR 97477
Office: 726-3759
Inspection Line: 726-3769
Location of Proposed Work: 886 RIVER KNOLL WAY
Assessors Map #: 17032343
Lot: 72 Block: .
Tax Lot #: 04600
Subdivision: RIVER GLEN 2
Owner: FUTURE B HOMES
Address: PO BOX 7425
Phone #: 744-2660
City/State/zip: EUGENE, OREGON 97401
Describe Work: S.F. RESIDENCE
NEW
Canst.
Contractor Contractor # Expires Phone
General: FUTURE B HOMES 0036499 05/18/00 485-3176
3593 River Pointe Dr Eugene OR 9740
Plumbing: CUSTOM PLUMBING 0081994 05/06/00 485-1146
3248 KENTWOOD DR EUGENE OR 97401000
Mechanical: ROLFS HEATING 0102455 10/04/98 741-0002
PO BOX 66 DEXTER OR 974310000
Electrical: BOB FISHER 0096275 01/25/99 689-7973
180 KINGSBURY AVE EUGENE OR 9740400
OFFICE USE --
LAND USE: 1111
ZONING CODE: LDR
# OF BDRMS: 4
WATER HEATER: G
ATTENTION:Qr@gllodavtmui~~ou to
follow rules adopted by the Oregon Utility
To request an ins~i!ij;alj9n~.rJ!ef,h1/1Qf'ij3 ~!l-aflee!l\:<<l:r!tg at 726 -3769.
in OAR 952-001-001 0 through OAR 952-001-
All inspections r~ll'il\!iIlJ3el'~ifl:QQPi!l.!!~! tlaEl.mle6.9llnade the same
inspections reguesteG\IIin9::\!1!l CImlllr.'(~le:.J\)l!1el>\p~ the following
number for the Oregon Utility Notification
Cel1twCltl~311N9P-1MliIONS - --
QUAD AREA: 2RNW
# OF UNITS: 1
CONSTR. TYPE: VN
SECONDARY HEAT: FP
INSUL PATH: PI
# OF BLDGS: 1
OCCY GROUP: R3
HEAT SOURCE: FG
RANGE: E
working day,
work day.
FOOTING - After trenches are excavated.
FOUNDATION - After forms are erected but prior to concrete placement.
UNDERFLOOR PLUMBING - Prior to insulation or decking.
UNDER FLOOR MECHANICAL - Prior to insulation or decking.
ROUGH GAS - after line is installed and capped if not attached to an
appliance
POST AND BEAM - Prior to floor insulation or decking.
INSULATION - Floor; prior to decking Wall/Ceiling; Prior to cover
WATER LINE - Prior to filling trench.
SANITARY SEWER LINE - Prior to filling trench.
STORM SEWER LINE - Prior to filling trench.
ROUGH PLUMBING - Prior to cover.
ROUGH MECHANICAL - Prior to cover.
ROUGH ELECTRICAL - Prior to cover.
ELECTRICAL SERVICE - Must be approved to obtain
SHEAR WALL NAILING - Before covering sheathing
FRAMING - Prior to cover.
INSULATION - Floor; prior to decking
DRYWALL - Prior to taping.
CURBCUT - After forms are erected but prior to placement of concrete.
SIDEWALK - After excavation is complete, forms and sub-base material
in place.
NOTICE:
THIS PERMIT SHALL EXPIRE IF THE WORK
AUTHORIZED UNDER THIS PERMIT IS NOT
COMMENCtED OR IS ABANDONED FOR
permanen power.
wj')~,<< 1&'h'i~~ PrfR!~ials.
Wall/Ceiling; Prior to cover
.,-" .
SPRINGFIELD
Job Number: 980968
Page 2
FINAL PLUMBING - When all plumbing work is complete.
FINAL MECHANICAL - When all mechanical work is complete.
FINAL ELECTRICAL - When all electrical work is complete.
GAS SERVICE - After line is installed and line has been connected to a
minimum of one appliance. Pressure test done at this point.
FINAL BUILDING - When all required inspections have been approved and
the building is complete.
Lot Faces: S
Topography: 2
Solar Approved: Y
Lot Sq. Ft.: 10049
Total Height: 26
Lot Type: INTERIOR
Setbacks
S W E
5
Lot Coverage: 22 %
Setbk From NPL: 70
N
House 54
Garage
21 11
Item
Main
Garage
Total Value
BUILDING PERMIT ---
Square Feet x
2193
703
$/Square Feet
64.66
16.27
Value
141,799.00
11,438.00
153,237.00
Building Permit Fee
Surcharge/Admin
554.50
44.37
TOTAL FEE
(A)
598.87
PLUMBING PERMIT ---
Item
Residential Bath(s)
3
Fee
192.50
Plumbing Permit
Surcharge/Admin
192.50
15.41
TOTAL CHARGE
(C)
207.91
--- MECHANICAL PERMIT ---
Furnace
Exhaust Hood
Vent Fan
Dryer Vent
GAS LINE & W/H
GAS F.P.
5
6.00
4.50
15.00
3.00
5.00
4.50
Mechanical Permit
Issuance
Surcharge/Admin
38.00
10.00
3.04
TOTAL PERMIT
(D)
51. 04
--- MISCELLANEOUS PERMITS ---
Surcharge/Admin
Sidewalk
Curb Cut
WILLAMALANE SDC
CITY SDC
ELECT. PERMIT.
0.00
22.45
16.30
1,000.00
3,259.05
156.60
TOTAL MISCELLANEOUS PERMITS
(E)
4,454.40
(Excluding Electrical)
unless otherwise noted
TOTAL AMOUNT DUE
(A, B, C, D, and E combined)
/ '
(5,312.22 ')
'-- --;fltO
r2.3rP~
..
.~.,
SPRINGFIELD
Job Number: 980968
Page 3
--- BUILDING VALUE, PLAN CHECK AND BUILDING PERMIT ---
This permit is granted on the express condition that the said construction
shall, in all respects, conform to the Ordinance adopted by the City of
Springfield, including the Development Code, regulating the construction and
use of buildings, and may be suspended or revoked at any time upon violation
of any provisions of said ordinances.
Plan Check Fee:
Received By:
Plans Reviewed By: DON
Building Site Reviewed
360.43
Date Paid: 08/04/98
Receipt Number: 30967
MOORE Date: 08/18/98
By: LISA HOPPER
--- ADDITIONAL COMMENTS ---
PATH 1;
DRIVEWAY REQUIRED TO BE PAVED
2 STREET TREES REQUIRED
By signature, I state and agree, that I have carefully examined
the completed application and do hereby certify that all information hereon
is true and correct, and I further certify that any and all work performed
shall be done in accordance with the Ordinances of the City of Springfield,
and the Laws of the State of Oregon pertaining to the work described herein,
and that NO OCCUPANCY will be made of any structure without permission of the
Community Services Division, Building Safety. I further certify that only
contractors and employees who are in compliance with ORS 701.055 will be
used on this project.
I further agree to ensure that all required inspections are requested at the
proper time, that each address is readable from the street, that the permit
card is located at the front of the property, and the approved set of plans
will remain on the site at all times during construction.
~~ - ~~
Si~
?)!}<1/g~
Date
.
- -- VALIDATION
Date Paid:
t/3/1,z....1
f/lq/f6
!S 3 / '7. S 8 ;J
dl tJ~
Receipt Number:
Amount Received:
Received By:
.
.
- ~1\
~t~9yy'i!'~~~!~~nt;, Job. No. Q9,(;q\g <6
;'. SYSTEM DEVELOPMENT CHARGE
\ ~ WORKSHEET
NAME: ~}. ~tlUl . ~ ~Or:;;J PHONE: l44 ,!JJAlp
ADDRESS~ D~. ~-4Q~ STATE: ~IP:o.146L
LOCATION OF PROPOSED BUILD~G. SITE: , '
Street Address: Mlo \)< 1\ 1Q f Jtnol.l \UPrc( )
Plat Name: .~~\ \\OJI lJIQJ\) Tax Lot Number: JJ h~n+3 rtUcC()
1. DEVELOPMENT TYPE (Check appropriate dwelling(s). SOC calculations and dwelling I
ype definitions are on the back.) .
A. Rinale-FHmilv DetHched
\ Single Family home
NO. OF UNITS (
Manufactured home not in a park
X $1,000 per unit = $ l (1)0.0()
B. Rinale'-FHmilv AttHched
NO. OF UNITS
X $924 per unit = $
C. Multi-Familv AOHrtment
NO. OF UNITS
X $692 per unit = $ .
D. M:mufHctured Home Park
NO. OF UNITS
X $699 per unit = $
L 1lJC() . 00
9f
$ lnm .00
,70; ,1'[
$
WILLAMALANE SDC
2.. SDC CREDIT (if applicable) SOG-payer must furnish proof of
Willamalane Credit approval. See SDC Credit Worksheet.
3. TOTAL WILLAMALANE NET SDC ASSESSED
~S)j~I"D ~
Development s~ Department Date
City of Springfield
. JOURNAL OR JOB NO.
ATTACHMENT A ~
CITY OF SPRINGFIELD SYSTEMS DEVELOPMENT CHARGE
WORKSHEET
NAME OR COMPANY:
fjLtu Ai '8 \-\n-w, 0 -"
LOCATION:
8R (~ 'Rivr"r 1c.Y"It,1l WtllJ
0'
I!;\ Q r"''''' i r\ Fg'\-ticA.,Q
DEVELOPMENT TYPE:
BUILDING SIZE:
2.1<:13 sF
LOT SIZE (tfJ 040
SQ. Ft.
1. STORM DRAINAGE
IMPERVIOUS SQ. FT.
'-10
2-~ + 9X'5'Z)
357,("
X $0.227 PER SQ. FT. $ ~()2..&>1
2. SANITARY SEWER-CITY
NO. OF PFU'S .' ~
(See Reverse Side)
X $47.14 PER PFU
$ f508, ~
3. TRANSPORTATION
NO OF UNITS X TRIP RATE X COST PER TRIP
. '\ \
\ ,
x \,0\
X $475.32
$ 4~. 01
x
X $475.32
$ -
4. SANITARY SEWER-MWMC
A. REIMBURSEMENT COST:
NO. OF FEU'S \. X 21'7,44..PER FEU
$ z:T7.44-
B. IMPROVEMENT COST:
NO. OF FEU'S \
X 25,'Z.OPER FEU
$ '2.5"2"
MWMC CREDIT IF APPLICABLE (SEE REVERSE)
MWMC ADMINISTRATIVE FEE
< $ . >
$ 1000
TOTAL-MWMC SDC
$ 3\ 'Z.,VT'
.,~lo.s.l?"
$ ,..',;; . CO
I ')J. 1'7
$~'
SUBTOTAL (ADD ITEMS 1.2.3 & 4)
5. ADMINISTRATIVE FEES:
BASE CHARGE (SUBTOTAL ABOVE) X .05
/t}) L-
SDC Coordinator
ATTACH' A. WPD
Da te : .1/14jqj"
3ZSC!.os
TOTAL SDC $ ~bDl'l ,"):'
FIXTURE UNIT CALCUL~ION TABLE: Number of New FiXe x Unit Equivalent = Fixture l:Jnits -"
(NOTE: For remodels, calculate onl. NET additional fixtures)
. NUMBER OF UNIT FIXTURE
FIXTURE TYPE NEW FIXTURES EQUIVALENT UNITS
Bathtub......................................:.............................. .
Drinking Fountain................. .,...................................
K Floor Drain..............W8:..p.(~.................................
Interceptors For Grease/Oil/Solids/Etc.................
Interceptors For Sand/Auto Wash/Etc..................
Laundry Tub/Clotheswasher...................................
Clotheswasher - 3 Or More............................:........
Mobile Home Park Trap (1 Per Trailer)..................
;If Receptor For Refrigerator/Water Station/Etc........
Receptor For Commercial Sink/Dishwasher/Etc..
Shower, Single Stall.....:..................:........................
Shower, Gang..........................................................
Sink: Bar, Commercial, Residential Kitchen........................
Urinal, Stall/WaiL............................. .........................
;ft: Wash Basin/Lavatory, Single..................................
Toilet, Public Installation........................,...............
Toilet, Private.......................................................
Miscellaneous:
"Z. 2 f-
ni 1
,1 2 "2.
15 3
rI 6
I 2 Z.
'1 6
~ 6
I, 1 I
\ 3 3
I 2 "2-
(') 1/Head
/P I 2 "2..
'" 2
5' 1 ':.
D 6
-3 4 I...
TOTAL FIXTURE UNITS
3'3
=
Credit for Parcel or Land Only If Applicable
X $ =
(Rate X Assessed Value)
X $ =
(Rate X Assessed Value)
CREDIT TOTAL = $
Improvement (if after armexation date)
RUNOFF COEFFICIENTS FOR STORM DRAINAGE
(For Estimating Purpo'ses Only)
ResidentiaL.......................... 0.4
CommericaL......................., 0.9
IndustriaL:.......................... 05
GovernmentaL..................... 0.5
FIXUNIT.WPO
IMPERVIOUS AREA = TOTAL LOT SIZE X RUNOFF COEFFICIENT