Loading...
HomeMy WebLinkAboutPermit Building 2002-7-11 . " . ~ . I Job# 02-00780-01 I Page 1 of 5 TRANS#:01-0009900 DATE:JUL 11 2C02 AMT RECD:2 $ 6732.96 CHANGE: CASHIER: 061 SPRINGPIELD ~ 225 Fifth Street Springfield, OR 97477 CITY OF SPRINGFIELD, OREGON RESIDENTIAL PERMIT City Of Springfield Community Services Division Building Safety Job Number: 02-00780-01 Office: 726-3759 Inspection Line: 726-3769 Location Of Proposed Site: 862 River Knoll Way Spr Assessors Map#: 17032343 Lot: 146 Block: Addition: 4th Owner: Address: Tax Lot#: 11400 Subdivision: River Glen Stan Karotko 3950 Goodpasture Rd Phone Number: 541-345-7997 City/State/Zip: Eugene, OR 97401 New Value: $216,642 Scope Of Work: Single Family Residence Contractor Jay Marcott 83879 N Enterprise, Pleasant Hill, OR 97455 Electrical Contr Bob Fisher Electric Inc 96275 180 Kingsbury Ave, Eugene, OR 97404 Mechanical Contr Comfort Flow Heating Co 00460 1951 Don Street, Springfield, OR 97477 Plumbing Contr Chapin Enterprises Incorporated 81994 3248 Kentwood Dr, Eugene, OR 97401 Contractor Type General Contr SFR Registration # Expiration Date 61303 8/18/2002 Phone 541-726-9287 1/25/2004 541-689-7973 6/27/2093 ..'.~' "541-726-0100 . ' .,' \-::., .' r ': I.d, '.\\ '. .', '. F \ -" ....." ,- . , . _~'(\u- ~ c\-~..... " ,...:\ . " 5/6(290~;\J\\\<"";'" ,5~;:~~5414.6 . . ~\..i ;4:"{" ,\,,\'" . _ ~ I. ~ I}' .-' .,'" ...~""... " ..'''".;.' Office Use >,.' '-..,_,~' ~r' <....t"..~.,..-_\. ....1"). ~ .\'~ , . I":' ~, Quad Area: 2RNW Land Use: Single Family Dwelling" # Of Buildings: 1 ..,' -" # Of Units: 1 Zoning Code: LDR ,,":; Occupancy Group: Dwelling Constr. Type: (VN) Wood Frame Bedrooms: 3 Heat Source: Forced Air Gas Water Heater: Gas Range: Electric Sq. Footage: 2645 To request an inspection call the 24 hour recording at 726-3769. All inspections requested before 7,;,QQ;.~~~ a.m. will be made the same working day, inspections requested after 7:00 a.m. will be made t~l4lto~~\g.,':1 working day. ~'?~ '?'t.~~ ...\;)~ . . r,' t."~\..\. 'I:~\':1 -n~'t.~ ReqUired Inspectu~fM'~'" ~\\ - S)'C." \>o.~v~ I Buildinll '''','f., '?'t.~~~'t.~ ~~ ~ \':1 \>o.~ -Install ground rod at footing, and call for ih~~~~~i\h footing and/or foundation ir -After trenches are excavated. 'Ill ~~l0 ~~ -After forms are erected but prior to concret~ ~~nt. -Prior to floor insulation or decking. ~ -Prior to decking. - Prior to cover. - Before covering sheathing with finish materials. - Prior to cover. Verify Ground Rod Footing Foundation Post and Beam Floor Insulation Ceiling Insulation Shear Wall Nailing Framing .. Wall Insulation Drywall Hold Downs Installed Vapor Barrierllnsulation Final Building Temporary Power Rough Electrical Electrical Service Final Electrical Underfloor Plumbing Underfloor Drain Rough Plumbing Water Line Sanitary Sewer Line Storm Sewer Line Perimeter Foundation Drains Final Plumbing Underfloor Mechanical Rough Gas Rough Mechanical Gas Service Final Gas Final Mechanical SW..curbside CC-Standard . Job# 02-00780-01 i Required Inspections Building I . - Prior to Cover - Prior to taping. Page 2 of 5 - To be made after insulation and required vapor barriers are in place, but prior to any wall coverir - When all required inspections have been approved and the building is complete. I Electrical I -Approval required prior to SUB energizing pole. - Prior to cover. - Must be approved to obtain permanent power. -When all electrical work is complete. I Plumbin!l - Prior to insulation or decking. - Prior to cover or placement of concrete. - Prior to cover. - Prior to filling trench. -Prior to filling trench. -Prior to filling trench. -After gravel and filter cloth is installed, but prior to backfill. -When all plumbing work is complete. I Mechanical -Prior to insulation or decking. -After line is installed and capped if not attached to an appliance. - Prior to cover. -After line is installed and line has been connected to a minimum of one appliance. Pressure tes -When all gas work is complete. -When all mechanical work is complete. I Public Works I -After forms are erected but prior to placement of concrete -After forms are erected but prior to placement of concrete Street Improvement: Fully Improved Curb Cut?~ Improvement Agr.?D San Sewer Depth (Ft): 6 4 Storm Sewer Available? 0 Special Req.: Security Required: Bond Begin DateTime: 00/00/0000 00:00:00 . Special Instructions: Other Utilities: Project Supervisor: Sidewalk Type: Additional ROW? Size Of Line (in): Downspouts/Drains: Enchroachment Permit: San Sewer Tee (in): Bond End DateTime: Curbside - 5' o 8 To Curb and Gutter 6 00/00/000000:00:00 . Types Of Warning Devices Reqd. .. . Zoning: LDR FloodPlain? 0 Wetlands? 0 Journal numbers 1: 2002-06-0188 2: Comments:Over Counter LDAP I Job# 02-00780-01 I Overlay District: # of Street Trees: 2 . 3: Additional Requirements: Required Attachments: Source Locn: Material: Planner: Urban Growth Boundary?D Glenwood Area? 0 Quantity Of Fill: Supplier: Drainage: Floodway FEMA: Zone X White Construction Types:(VN) Wood Frame Occupancy Groups: Dwelling # Of Buildings: 1 # Of Bedrooms: 3 Handicap Access? 0 ,Area (Sq. Feet) I Main: 2645 Accessory:986 Fee Residential Plan Check Total Plan Check Building Permit State Surcharge For Building Permit 8% Building Administrative Fee Total Building Minimum Electrical Permit Fee Wiring Footage 1,000 Sq Ft or Less Wiring Footage Each Add'l 500 Sq Ft Temporary: 200 Amps or Less State Surcharge - Electrical 8% Admin Fee - Electrical Total Electrical Minimum Plumbing Permit Fee Three Bathrooms State Surcharge - Plumbing 8% Administrative Fee - Plumbing Total Plumbing Hood and Exhaust One to Four Outlets Minimum Mechanical Permit 8% Administrative Fee - Mechanical Less than 100,000 BTU Vent Fan to One Duct Page 3 of 5 Land Use: Single Family Dwelling Pave Driveway? 0 Flood Plain FEMA: Panel 1134 of 2975 Private Garage/Carp/Stor # Of Stories: 2 Height (feet): 27 Current Units: Proposed Units:1 Census Code: New SF - detached Total:3631 Paid On Receipt# Plan Check 06/28/2002 9779 Buildin!l 07/11/2002 9900 07/11/2002 9900 07111/2002 9900 Electrical 07/11/2002 9900 07/11/2002 9900 07/11/2002 9900 07111/2002 9900 07/11/2002 9900 07/11/2002 9900 Plumbing 07/11/2002 9900 07/11/2002 9900 07111/2002 9900 07111/2002 9900 Mechanical 07111/2002 9900 07/11/2002 9900 07/11/2002 9900 07/11/2002 9900 07/11/2002 9900 07/11/2002 9900 Value/Quantity Fee Amount 216,642 $614.84 $614.84 216,642 $945.90 $66.21 $75.67 $1,087.78 1 6 , 1 $.00 $106.00 $114.00 $50.00 $18.90 $21.60 $310.50 1 $.00 $306.00 $21.42 $24.48 $351.90 1 1 $9,00 $4.00 $.00 $5.12 $12.00 $24.00 1 4 , . Job# 02-00780-01 Paid On Receipt# Mechanical 07111/2002 9900 07111/2002 9900 07111/2002 9900 07/11/2002 9900 1 1 . Fee Page 4 of 5 Value/Quantity Fee Amount Gas Fireplace Dryer Vent Mechanical Issuance State Surcharge - Mechanical Total Mechanical New Sidewalk New Curbcut Multiple Permit Discount - 2nd Permit Total Public Works Public Works 07/11/2002 9900 07/11/2002 9900 07/11/2002 9900 40 1 1 Residential - Single Family - Storm Residential Improvement MWMC MWMC Administrative Fee SDC Administrative Fee Residential Sanitary MWMC Residential - Improvement Residential - Reimbursement Sanitary Sewer SDC Reimbursement Sanitary Sewer SDC Improvement Total System Development System Development 07/11/2002 9900 07/11/2002 9900 07/11/2002 9900 07/11/2002 9900 07111/2002 9900 07111/2002 9900 07111/2002 9900 07/11/2002 9900 07111/2002 9900 1 1 1 31 31 4,325 1 1 S.F. Residence - Willamalane Total Willamalane SDC Willamalane SDC 07/11/2002 9900 1 Planning Plan Review Total Planning Planning 07/11/2002 9900 1 Address Assignment Total Permits w/o Srchg Grand Total Plan Check Type Permits w/o Srchg 07/11/2002 9900 1 Checked By Date Completed Comment Initial Review-Res Engineering-Res Planning-Res Structural-Res Lisa Hopper Denny Wright Liz Miller Bob Barnhart 07/01/2002 07/09/2002 07/05/2002 07/03/2002 By signature, I state and agree, that I have carefully examined the completed application and do hereby certify that all information hereon is true and correct, and I further certify that any and all work performed shall be done in accordance with the Ordinances of the City of Springfield and the Laws of the State of Oregon pertaining to the work described herein, and that NO OCCUPANCY will be made of any structure without permission of the Community Services Division, Building Safety. I further certify that only contractors and employees who are in compliance with ORS 701.055 will be used on this project. I further agree to ensure that all required inspections are requested at the proper time, that each address is readable from the street, that the permit card is located at the front of the property, and the approved set of plans will remain on the site at all times during construction. $9.00 $6.00 $10.00 $4.48 $83.60 $75.00 $75.00 $-30.00 $120.00 $1,180.73 $34.83 $10.00 $176,96 $332.86 $659.76 $155.13 $662.47 $503.44 $3,716.18 $1,000.00 $1,000.00 $55.00 $55.00 $8.00 $8.00 $7,347.80 '. 11'~) a JI~ b.~ ; .- Signature . I Job# 02-00780-01 I . Page 5 of 5 ) ) Ii In ~ Date