HomeMy WebLinkAboutMiscellaneous Specifications 2003-10-1
.
CertainTeed II
Builders Statement
.
..
C5-0(72&-1
InsulSafe@4
Fiber Glass Blowing Insulation
;::cJTJr~ g fIo""", S
H"omeowner Name / Jobsite Name
%? f{ q 9..ur /N/T /1
Home Address
~ .--'
. ~:I In,. /'tv
Installer/Contracr (sign)
Builder (sign)
Inspected By (sign if required)
R-VALUE
.
To obtain a
Thermal Resistance
(R)of:
60
49
44
38
30
26
22
19
13
"
CEILINGS
WALLS
FLOORS
h~ J/)~J in"" 6
Company Name
(}',dh.,.. \ \ d. (/ 6 '5
Date
Company Name
Date
Date
BAGS PER MAXIMUM MINIMUM WEIGHT- MINIMUM
1000 SQ. FT. SQ. FT. PER BAG POUNDS PER SQ. FT. THICKNESS
Bags per Conlenlsof bag Weight per sq. ftof Should not be
IOOOsQ.ft should noleaver installed insulation should less than:
of net area: more than: (sq.ft.) not be less than: Obs.J On.)
36.5 27 0,986 22
29.6 34 0,800 181f.!
26.4 38 0.712 16Y.
22,8 44 0.615 14%
18.0 SO 0.485 12
15.5 65 0.418 101,7
13.1 76 0,353 9
11.1 90 0,301 7~.
7,7 129 0.209 51;
6,6 151 0.179 40/.
R-VALUE THICKNESS AREA [SQ, FT.) INSUlSAFE. [7 BAGS USED BATTS/ROLLS (.....)
3e; ) l{ '3/'-1 'N45 V 3</ /'
So 5'n
/
.;2 ( /..5Q 0 V
~5 ~O{JO /
THERMAL PERFORMANCE-ArnC BLOWING APPLICATION
In accordance with the chart above, you must install the minimum number of bags per 1,000 sq, It. of net area for each
R.Value listed,
The maximum net coverage must not exceed that specified for each R-Value.
The installed insulation must be at or above the specified minimum thickness for each R.Value,
Failure to install the required minimum weight per sq. It. of insulation at or above the minimum thickness will result in
reduced R-Value.
This product should not be mixed with other blown insulations or the thermal claims will become invalid,
.
DANGER: RECESSED LIGHT FIXTURES-TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF
SUCH DEVICES. DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT FIXTURES WITH
THERMALLY PROTECTED BALLASTS.
30.24.233 Builders Statement
A Saint.Gobain Company
C2002 CertainTeed Corporation 11/02
.
Manufacturer Insulation Fact Sheet
This is CertainTeed Corporation InsulSafe@4'
Fiber Glass Blowing Insulation
CerlainTeed Corporation
P,O, Box 860
Valley Forge, PA 19482
.
CertainTeed e
.
THERMAL PERFORMANCE-HORIZONTAL OPEN BLOW
The following thermal performances are achieved at weights and coverages specified when insulation is installed with
pneumatic equipment in a horizontal open blow application:
BAGS PER MAXIMUM MINIMUM WEIGHT- MINIMUM
R-VALUE 10005Q, FT, 5Q, FT, PER BAG POUNDS PER sQ, FT, THICKNESS
To obtain a Bags per Contents of bag W~hl per SQ. ft. of Should not be
Thermal Resistance 1000 sq. ft. should not cover install insulation should less than:
(R)of: ofnelarea: more than: (sq. ft.) nOI be less than: (Ibs.) (in.)
60 36,S 27 0,986 22
49 29,6 34 0,800 181f2
44 26.4 38 0.712 16)/~
38 22.8 44 0,615 14]/~
30 18,0 56 0.485 12
26 15,5 65 0.418 lO1f2
22 13,1 76 0,353 9
19 11,1 90 0,301 71/~
13 7.7 129 0,209 51/1
11 6,6 151 0,179 4lf4 .
R-values are determined in accordance with ASTM C 687 and C 518. Complies with ASTM C 764 as Type 1 insulation,
THERMAL PERFORMANCE-SIDEWALL RETROFIT APPLICATION
When installed with pneumatic equipment in sidewalls, the following thermal performances are achieved at the
Ihicknesses, weights and coverages specified.
BAGS PER MAXIMUM MINIMUM WEIGHT- MINIMUM
R.VALUE 1000 SQ. FT. SQ. FT. PER BAG POUNDS PER SQ. FT. THICKNESS
To obtain a Bags per (ontentsofbag W~hl per sq. {t. of Should not be
Thermal Resistance 1000 sq. ft should noleover install insulation should less than:
(Rlof: ofnclarea: morc Ihan: (sq. fl.) not be less than: (Ibs.) (in.)
29 35,8 28 0.967 71/~
22 27,2 37 0.733 5112
16 19,8 51 0,533 4
15 17,9 56 0.484 3%
14 17.3 S8 0.467 3112
READ THIS BEFORE YOLJ BLJY
What you should know about R-Values.
The chart shows the R-Value of this insulation, R means resistance to heat flow, The higher the R-
Value, the greater the insulating power, Compare insulation R-Values before you buy,
There are other factors to consider, The amount of insulation you need depends mainly on the
climate you live in, Also, your fuel savings from insulation will depend upon the climate, the type
and size of your house, the amount of insulation already in your house, and your fuel use
patterns and family size, If you buy too much insulation, it will cost you more than what you'll
save on fuel.
To get the marked R-Value. it is essential that this insulation be installed properly,
.