R-VALUE
.
To obtain a
Thermal Resistance
{R}of:
60
49
44
3a
30
26
22
19
13
11
e"-
10!tn
umw
InsulSafe@4
Fiber Glass Blowing Insulation
K/\,od
;lor>(? ..J:~d 10 T /O/lC.
BAGS PER
1000 SQ. FT.
Bags per
1000 sq. fl
of net area:
36,S
29,6
26.4
22,8
18.0
15.5
13.1
11.1
7,7
6,6
Company Name
Company Name
MAXIMUM
SQ, FT. PER BAG
Contents of bag
shoutdnotcover
morelhan: (sq. ft)
27
34
38
44
56
65
77
90
129
151
MINIMUM WEIGHT-
POUNDS PER SQ. FT.
Weight per sq. ft.of
installed insulation should
not be lesslhan: Ubs.)
0.986
0.800
0.712
0.615
0.485
0.418
0.353
0.301
0,209
0.179
R-VALUE THICKNESS AREA (SQ. FT.) INSUlSAFE 4 (tI)
, "50 200 ./
CEILINGS ,~R / L/ 'J/c{ /6;65 V
WALLS .;L\
;),l\DO
FLOORS /'R' 0 0
.1S
THERMAL PERFORMANCE-ATTIC BLOWING APPLICATION
()\~atJ ~ C. :< () (j Y
Date
Date
INSTALLED
MINIMUM THICKNESS
Should not be
less than:
On.)
22
18'h
163ft
140/4
12
10'h
9
7%
51;
4%
BAGS USED
BATTS/RO~)
1/
40
/'
V
/
/
V
In accordance with the chart above. you must install the minimum number of bags per 1,000 sq. ft of net area for each
R-Value listed.
The maximum net coverage must not exceed that specified for each R-Value.
The installed insulation must be at or above the specified minimum thickness for each R.Value.
Failure to install the required minimum weight per sq. ft of insulation at or above the minimum thickness will result in
reduced. R-Value,
This product should not be mixed with other blown insulations or the thermal claims will become invalid.
I
.
DANGER:, RECESSED LIGHT FIXTURES-TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF
SUCH OEVICES. DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT FIXTURES WITH
THERMALLY PROTECTED BALLASTS.
30-24-233 Builders Statement
A Saint.Gobain Company
C2003 CertainTeed Corporation 10/03
I
'.
.
CertainTeed 1:-1
*
.
Manufacturer Insulation Fact Sheet
This is CertainTeed Corporation InsulSafe@4
Fiber Glass Blowing Insulation
CertainTeed Corporation
P.O. 80x 860
Valley Forge, PA 19482
THERMAL PERFORMANCE-HORIZONTAL OPEN BLOW
The following thermal performances are achieved at weights and coverages specified when insulation is installed with
pneumatic equipment in a horizontal open blow application:
BAGS PER MAXIMUM MINIMUM WEIGHT- MINIMUM
R.VAlUE 1000 SQ. FT. SQ. FT. PER BAG POUNDS PER SQ, FT, THICKNESS
To obtain a ~5per Contents of bag we~tt per sq. ft. of Should not be
Thermal Resistance 1 sq.f!. should not cover install insulation should tesslhan:
(Rlof: of net area: more than: (sq. ft.l not be less than: (Ibs.l (in.)
60 36,5 27 0,986 22
49 29,6 34 0,800 181h
44 26.4 38 0.712 16lf~
38 22,8 44 0,615 14l/~
30 18,0 56 0.485 12
26 15.5 65 0.418 10112
22 13,1 77 0,353 9
19 11.1 90 0,301 73/4
13 7.7 129 0,209 5'h
11 6,6 151 0,179 43/4 .
R-values are determined in accordance with ASTM C 687 and 518, Complies with ASTM C 764 as Type 1 insulalion,
~ THERMAL PERFORMANCE-SIDEWALL RETROFIT APPLICATION
When installed with pneumatic equipment in sidewalls, the following Ihermal performances are achieved at the
Ihicknesses, weights and coverages specified. Based on a design density of 1.6 pcf125.6 KglmJ.
BAGS PER MAXIMUM MINIMUM WEIGHT- MINIMUM
R-VALUE 1000 SQ, FT, SQ. FT. PER BAG POUNDS PER SQ. FT. THICKNESS
To obtain a B~sper (ontents of bag W~ht per sq. ft. of Should not be
.' Thermal Resistance 10 sq. ft. should not cover install insulation should lesslhan:
(Rlof: of nel area: more than: (sq. ft.) not be less than: (Ibs.) (in.)
29 35,8 26 0.967 71/~
22 27,2 37 0.733 51{2
16 19,8 51 0.533 4
15 17,9 56 0.483 3%
14 17,3 58 0.467 31/2
READ THIS BEFORE YOU BUY
What you should know about R-Values.
The chart shows the R-Value of this insulation. R means resistance to heat flow, The higher the R-
Value, the greater the insulating power. Compare insulation R.Values before you buy,
There are other factors to consider. The amount of insulation you need depends mainly on the
climate you live in. Also, your fuel savings from insulation will depend upon the climate, the type
and size of your house, the amount of insulation already in your house, and your fuel use .
patterns and family size, If you buy too much insulation, it will cost you more than what you'll
save on fuel.
To get the marked R-Value, it is essential that this insulation be installed properly,
J
'\ ;.