CertainTeed II
Builders Statement
.
FuTvr-e :$
Homeowner Name I Jobsite Name
~'41Z\VH
Home Address
t2:/ -r;;:,J.r
(nstalrer/Contfaflor (sign)
.
InsulSafe@4
Fiber Glass Blowing Insulation
K',..fJII
H6IYlf: 'J;,SJ~"ilOII e.
CEILINGS . ~&'
J# 0/", ~'IIS
WALLS I
.2./ l. V" 1/;{oO
FLOORS i
~i) 8 I u2~/ 5'
Builder (sign)
Inspected By (sign if required)
R-VALUE
.
To obtain a
ThenTlal Resistance
(A)al:
60
49
44
38
30
26
22
19
13
11
BAGS PER
1000 SQ. FT.
Bags per
IOOOsq.ll
al net area:
36,5
29,6
26.4
22.8
18.0
15.5
13.1
11.1
7,7
6,6
R-VALUE
Company Name
4",' ( ~ Z-dd.3
Date
Company Name
Date
Date
MAXIMUM
SQ. FT. PER BAG
Contents of bag
should not cover
more than: (sq. ft)
27
34
38
44
56
65
77
90
129
151
MINIMUM WEIGHT-
POUNDS PER SQ. FT.
WeighlpersQ. ftaf
installed insulation should
not be less than: Obs.)
0,986
0,800
0.712
0.615
0.485
0.418
0.353
0.301
0.209
0.179
MINIMUM
THICKNESS
Should not be
lessthan:1
On.)
22
18%
160/4
140/.
12
10%
9
7%
5%
40/.
THICKNESS
AREA (SQ, FT,)
INSULSAFE 4 (....)
BAGS USEO
BATTS/ROLLS (VI
/
V
50
./
V/
/
THERMAL PERFORMANCE-ArnC BLOWING APPLICATION
In accordance with the chart above, you must install the minimum number of bags per 1,000 sq, It of net area for each
R-Value listed.
The maximum net coverage must not exceed that specified for each R-Value,
The installed insulation must be at or above the specified minimum thickness for each R-Value,
Failure to install the required minimum weight per sq. It of insulation at or above the minimum thickness will result in
reduced R-Value.
This product should not be mixed with other blown insulations or the thermal claims will become invalid,
.
DANGER: RECESSED LIGHT FIXTURES-TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF
SUCH OEVICES. DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT FIXTURES WITH
THERMALLY PROTECTED BALLASTS.
30.24.233 Builders Statement
A Saint.Gobain Company
C2002 CertainTeed Corporation 1/02
.
Manufacturer Insulation Fact Sheet
This is CertainTeed Corporation InsulSafe@4
Fiber Glass Blowing Insulation
CertainTeed Corporation
P.O. Box 860
Valley Forge, PA 19482
.
CertainTeed t..
.
THERMAL PERFORMANCE-HORIZONTAL OPEN BLOW
The following thermal performances are achieved at weights and coverages specified when insulation is installed with
pneumatic equipment in a horizontal open blow application:
BAGS PER MAXIMUM MINIMUM WEIGHT- MINIMUM
R-VALUE 1000 SQ. FT. SQ. FT. PER BAG POUNDS PER SQ. FT. THICKNESS
To oblain a Bags per (ontents of bag W~hl per sq. ft. of Should not be
Thermal Resistance 1000 sq. ft. should not cover install insulation should le5sthan:
(Rloi: ofnelarea: more lhan:(sq. ft.) not be less than: (Ibs.l (in.)
60 36.5 27 0,986 22
49 29,6 34 0,800 18112
44 26.4 38 0.712 16J/4
38 22,8 44 0,615 143/4
30 18,0 S6 0.485 12
26 15,5 65 0.418 10'1z
22 1],1 77 0.353 9
19 11.1 90 0.301 ?lI4
1] 7.7 129 0,209 51/1
11 6,6 151 0,179 43/4 .
R-values are'determined in accordance with A5TM C 687 and 518, Complies with A5TM C 764 as Type 1 insulation,
THERMAL PERFORMANCE-SIDEWALL RETROFIT APPLICATION
When installed with pneumatic equipment in sidewalls, the following thermal performances are achieved at the
thicknesses, weights and coverages specified,
BAGS PER MAXIMUM MINIMUM WEJGHT- MINIMUM
RNAlUE 1000 SQ. FT. SQ. FT. PER BAG POUNDS PER sQ, FT, THICKNESS
To obtain a Bags per Contents of bag W~ht per sq. ft. of Should not be
Thermal Re5islance 1000 sq. ft. should not cover install insulation should less than:
(R)of; of net area: more than: (sq. ft.) not be less than: (Ibs.) (in.)
29 3S,8 28 0.967 71/~
22 27,2 37 0.733 51/2
16 19,8 51 0,533 4
15 17,9 56 0.483 3%
14 17.3 S8 0.467 31fl
READ THIS BEFORE YOLJ BLJY
What you should know about R-Values,
The chart shows the RNalue of this insulation, R means resistance to heat flow. The higher the R-
Value, the greater the insulating power. Compare insulation R-Values before you buy,
There are other factors to consider. The amount of insulation you need depends mainly on the
climate you live in, Also, your fuel savings from insulation will depend upon the climate, the type
and size of your house, the amount of insulation already in your house, and your fuel use .
patterns and family size, If you buy too much insulation, it will cost you more than what you'll
save on fuel.
To get the marked R-Value, it is essential that this insulation be installed properly,