Loading...
HomeMy WebLinkAboutMiscellaneous Specifications 2004-4-22 . . . , CertainTeed II Builders Statement .' e * InsulSafe~4 Fiber Glass Blowing Insulation - '''i)' r OJ TJ r-p .r:> Hll,....,~S' Homeowner Name / Jobsite Name f?/( ((, .ll,.. K':O/( Home Address ~ ',l -r;; fa ( H O~ .J-A<',) hT ((V1 C Installer/Contractor (5(9n) Company Name f)"I",' I :J.::) :J () (J 4 bate Builder (sign) Company Name Date Inspected By (sign jf required) Date R-VALUE BAGS PER 1000 SQ. FT. Bags per 1000 sq. ft of net area: 36,5 29,6 26.4 22.8 I 18.0 I 15,5 I 13,' 1..,'- 11.1 I 7,7 I 6,6 INSTALLED MINIMUM THICKNESS Should nol be less than: On.) 22 1BY1 160/. 140/. 12 10Y.! 9 7\'. 51> 4\'. MAXIMUM SQ. FT. PER BAG Conlenlsof bag should noleaver more than: (sq. fl.) 27 34 36 44 56 65 77 90 129 151 MINIMUM WEIGHT. POUNOS PER SQ. FT, Weight per sq. ft of installed insulation should not be less Ihan: Obs.) 0,966 0,600 0.712 0.615 0.485 0.418 0,353 0.301 0,209 0.179 Tocbtsine Thermal Resistance (A)af: 60 49 44 38 30 26 22 19 , 13 11 INSULSAFE 4 (oil BAGS USEO BATTS/ROLLS (oil / V' 47 / / V , THERMAL PERFORMANCE-ArnC BLOWING APPLICATION fn accordance with the chart above"you must install the minimum number of bags per 1 ,000 sq, It of net area for each R-VaJue listed, . The maximum net coverage must not exceed that specified for each R-Value. The installed Insulation must be at or above the specified minimum thickness for each R-Value. Failure to install the required minimum weight per sq. It of insulation at or above the minimum thickness will result in reduced R-Value, - :/This product should not be mixed with other blown insulations or the thermal claims will become invalid, DANGER: RECESSED LIGHT FIXTURES-TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF SUCH DEVICES. DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT FIXTURES WITH THERMALLY PROTECTED BALLASTS. 30.24.233 Builders Statement A Saint-Gobain Compllny C2003 CertainTeed Corporation 10103 e Manufacturer Insulation Fact Sheet This is CertainTeed Corporation InsulSafe@4 Fiber Glass Blowing Insulation CertainTeed Corporation P.O. Box 860 Valley Forge, PA 19482 , CertainTeed II . . THERMAL PERFORMANCE-HORIZONTAL OPEN BLOW The following thermal performances are achieved at weights and coverages specified when insulation is installed with pneumatic equipment in a horizontal open blow application: BAGS PER MAXIMUM MINIMUM WErGHT- MINIMUM R-VAlUE 1000 SQ. FT. SQ. FT. PER BAG POUNDS PER SQ, FT, THICKNESS loohtaln a BaaS per (ontents of bag W~hlpersq.ft.of Should not be Thermal Resistance 100 sq. ft. should nolcover install insulation should less than: (R)o{: oine! area: more than: (sq. ft.) not be less than: (Ibs.) (in.) 60 36.5 27 0,986 22 49 29,6 34 0,800 18112 44 2604 38 0.712 16lJ4 38 22.8 44 0,615 14lJ4 30 18,0 56 00485 12 26 15,5 65 00418 10112 22 13,1 77 0.353 9 19 11.1 90 0.301 7J/4 13 7,7 129 0,209 5'h 11 6,6 151 0,179 4lf4 . R-values are determined in accordance with ASTM C 687 and 518. Complies with ASTM C 764 as Type 1 insulation, THERMAL PERFORMANCE-SIDEWALL RETROFIT APPLICATION When installed with pneumatic equipment in sidewalls, the following thermal performances are achieved at the thicknesses, weights and coverages specified. Based on a design density of 1,6 pcf/25,6 KglmJ, ~_.....~ - BACS PER MAXIMUM MINIMUM WEIGHT- MINIMUM R-VALUE 1000 SQ. FT. SQ. FT. PER BAG POUNDS PER SQ. FT. THICKNESS Toohtain a ~sper Contents of bag W~hl per sq. fl. of Should not be Thermal Resistance 1 sq.ft. should not cover install insulation should less than: (R)of: of net area: more than: (sq.ft.) not be less than: Obs.) (in.) 29 3S,8 28 0.967 71/. 22 27,1 37 0.733 51f2 16 19,8 51 0.533 4 15 17,9 56 00483 3% 14 17,3 S8 00467 31/1 READ THIS BEFORE YOU BUY What you should know about R-Values, The chart shows the R-Value of this insulation, R means resistance to heat flow, The higher the R- Value, the greater the insulating power. Compare insulation R-Values before you buy, There are other factors to consider. The amount of insulation you need depends mainly on the climate you live in, Also, your fuel savings from insulation will depend upon the climate, the type and size of your house, the amount of insulation already.in your house, and your fuel use patterns and family size, If you buy too much insulation;'it will cost you more than what you'll save on fuel. To get the marked R-Value, it is essential that this insulation be installed properly, .