HomeMy WebLinkAboutMiscellaneous Specifications 2004-4-22
.
.
.
,
CertainTeed II
Builders Statement
.'
e
*
InsulSafe~4
Fiber Glass Blowing Insulation
- '''i)'
r OJ TJ r-p .r:>
Hll,....,~S'
Homeowner Name / Jobsite Name
f?/( ((, .ll,.. K':O/(
Home Address
~ ',l -r;; fa ( H O~ .J-A<',) hT ((V1 C
Installer/Contractor (5(9n) Company Name
f)"I",' I :J.::) :J () (J 4
bate
Builder (sign)
Company Name
Date
Inspected By (sign jf required)
Date
R-VALUE
BAGS PER
1000 SQ. FT.
Bags per
1000 sq. ft
of net area:
36,5
29,6
26.4
22.8
I 18.0
I 15,5
I 13,'
1..,'- 11.1
I 7,7
I 6,6
INSTALLED
MINIMUM THICKNESS
Should nol be
less than:
On.)
22
1BY1
160/.
140/.
12
10Y.!
9
7\'.
51>
4\'.
MAXIMUM
SQ. FT. PER BAG
Conlenlsof bag
should noleaver
more than: (sq. fl.)
27
34
36
44
56
65
77
90
129
151
MINIMUM WEIGHT.
POUNOS PER SQ. FT,
Weight per sq. ft of
installed insulation should
not be less Ihan: Obs.)
0,966
0,600
0.712
0.615
0.485
0.418
0,353
0.301
0,209
0.179
Tocbtsine
Thermal Resistance
(A)af:
60
49
44
38
30
26
22
19
, 13
11
INSULSAFE 4 (oil
BAGS USEO
BATTS/ROLLS (oil
/
V'
47
/
/
V
, THERMAL PERFORMANCE-ArnC BLOWING APPLICATION
fn accordance with the chart above"you must install the minimum number of bags per 1 ,000 sq, It of net area for each
R-VaJue listed, .
The maximum net coverage must not exceed that specified for each R-Value.
The installed Insulation must be at or above the specified minimum thickness for each R-Value.
Failure to install the required minimum weight per sq. It of insulation at or above the minimum thickness will result in
reduced R-Value, -
:/This product should not be mixed with other blown insulations or the thermal claims will become invalid,
DANGER: RECESSED LIGHT FIXTURES-TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF
SUCH DEVICES. DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT FIXTURES WITH
THERMALLY PROTECTED BALLASTS.
30.24.233 Builders Statement
A Saint-Gobain Compllny
C2003 CertainTeed Corporation 10103
e
Manufacturer Insulation Fact Sheet
This is CertainTeed Corporation InsulSafe@4
Fiber Glass Blowing Insulation
CertainTeed Corporation
P.O. Box 860
Valley Forge, PA 19482
,
CertainTeed II
.
.
THERMAL PERFORMANCE-HORIZONTAL OPEN BLOW
The following thermal performances are achieved at weights and coverages specified when insulation is installed with
pneumatic equipment in a horizontal open blow application:
BAGS PER MAXIMUM MINIMUM WErGHT- MINIMUM
R-VAlUE 1000 SQ. FT. SQ. FT. PER BAG POUNDS PER SQ, FT, THICKNESS
loohtaln a BaaS per (ontents of bag W~hlpersq.ft.of Should not be
Thermal Resistance 100 sq. ft. should nolcover install insulation should less than:
(R)o{: oine! area: more than: (sq. ft.) not be less than: (Ibs.) (in.)
60 36.5 27 0,986 22
49 29,6 34 0,800 18112
44 2604 38 0.712 16lJ4
38 22.8 44 0,615 14lJ4
30 18,0 56 00485 12
26 15,5 65 00418 10112
22 13,1 77 0.353 9
19 11.1 90 0.301 7J/4
13 7,7 129 0,209 5'h
11 6,6 151 0,179 4lf4 .
R-values are determined in accordance with ASTM C 687 and 518. Complies with ASTM C 764 as Type 1 insulation,
THERMAL PERFORMANCE-SIDEWALL RETROFIT APPLICATION
When installed with pneumatic equipment in sidewalls, the following thermal performances are achieved at the
thicknesses, weights and coverages specified. Based on a design density of 1,6 pcf/25,6 KglmJ,
~_.....~ -
BACS PER MAXIMUM MINIMUM WEIGHT- MINIMUM
R-VALUE 1000 SQ. FT. SQ. FT. PER BAG POUNDS PER SQ. FT. THICKNESS
Toohtain a ~sper Contents of bag W~hl per sq. fl. of Should not be
Thermal Resistance 1 sq.ft. should not cover install insulation should less than:
(R)of: of net area: more than: (sq.ft.) not be less than: Obs.) (in.)
29 3S,8 28 0.967 71/.
22 27,1 37 0.733 51f2
16 19,8 51 0.533 4
15 17,9 56 00483 3%
14 17,3 S8 00467 31/1
READ THIS BEFORE YOU BUY
What you should know about R-Values,
The chart shows the R-Value of this insulation, R means resistance to heat flow, The higher the R-
Value, the greater the insulating power. Compare insulation R-Values before you buy,
There are other factors to consider. The amount of insulation you need depends mainly on the
climate you live in, Also, your fuel savings from insulation will depend upon the climate, the type
and size of your house, the amount of insulation already.in your house, and your fuel use
patterns and family size, If you buy too much insulation;'it will cost you more than what you'll
save on fuel.
To get the marked R-Value, it is essential that this insulation be installed properly,
.