Loading...
HomeMy WebLinkAboutSpecial Inspection Field Test & Inspection Report 2001-6-19 ..Jun c:.c:. U 1 11: .::l.::l3 K.C'Vln M.t-'C'r-erson l~'t1J 688-3020 p. 1 Dwell Grover Eilyhu:eriog P..C. 1050 Bethel Or. Suite # D 4 Eugene, Oregon 97402 (541) 688-3020 C~'j " · -lbV June 19,2001 Town & Country Homes 35920 Ellington Dr. Springfield, Oregon 97478 Re: (,X80 Glaci_e(,_Sprin0idd. OreQon Job # on 1{2 , . As you requested I performed site soils inspections on June 15 & 18,200 I at the above noted location, During that inspection I made the following observations, . TIle site soils con~i:>l of an 8 - 12 inch laycr of organic lOp~oil with a ~ub soil of clay that is dispersed with large boulders, The clay is classified as a CH in accordance \.\.'lth the uses system. The PI oflhe soil is approximated at a value greater then 35 making it have a veIY high degree of expansion (After l10ltz 1959), Recommendations for the site:: are U$ follows June 15, 2001 The site needs to have all of the organic layer removed and place a minimum of 12 inches of crushed rock a~ a base for the foundation. The rock needs to be compacted to 95% of a standard proctor. The native grade needs to be cut so that it slopes towards the natural fan at the NW corner of thc'\ot so that no w~ter can sit on the sub surface. June 18,2001 The ~ite has been prepared in accordance with my recommendations as stated above, The rock is placed to - a minimum of95% compaction based on a standard pr(lctor, The as constructed is adequate to support a standard residential foundation, Thank you for this opportunity to be or sClvice. Tfyou have any questions please don't hesitate to call me at (541) 688-3020 . Very truly yours '. Owen Grover P. E, Excites: 6-30-03