HomeMy WebLinkAboutBuilding Correspondence 1977-2-15
.
-
CITY OF SPRINGFIELD
SPRINGFIELD. OREGON 97477
DEPARTMENT OF
PUBLIC WORKS
February 15, 1977-
348 MAIN STREET
747.4221
Mr. Galen Ness
38442 Upper Camp Creek Road
Springfield, OR 97477
RE: 1910 'Scott Road, Housing Inspection
Dear Mr. Ness:
At your request the Building Department of the City of Springfield made a housing
inspection on February 14, 1977, at 1910 Scott Road, Springfield, Oregon.
The following items were found to be in need of repair or replacement to conform
to the Uniform Housing Code as adopted by the City of springfield.
1. All the windows must open freely.
2. A 'stricker plate should be installed on the rear bedroom door, and the door
should open and close freely.
3. The exhaust fan in the range hood needs repair.
4. There must be a six foot-six inch clear headroom at the steps leading from
the utility room to the garage.
5. The ceiling and walls of the garage must be covered with 5/8" type-X sheetrock
to provide a I-hour fire protection. The wall with the fireplace. in it is
approved as is (west wall) .
6. The attic area was not designed as a habitable area and should be used for
storage only.
7. The receptacle on the west wall in the garage has reversed polarity.
8. A main breaker is required ahead of all 15 & 20 amp breakers.
9. All wire must be spliced in an approved manner and said splices must be
made in an approved junction box.
All necessary permits must be obtained before work begins, and all work must
be accomplished according to applicable codes and inspected before a Certificate
of Compliance will be issued.
Should you have any questions, please feel free to contact the Springfield Building
Department' at 726-3753.
Sincerely,
(J~~
Dan Smith
Building Inspector
DS:snun