HomeMy WebLinkAboutBuilding Correspondence 1981-4-7 . e CITY OF SPRINGFIELD SPRINGFIELD, OREGON 97477 PUBLIC WORKS April 7, 1981 :346 MAIN STREET 726-3753 Mr. Neil Christensen 4835 N.W. 273rd Avenue Hillsboro, Oregon 97123 / SUBJECT: HOUSING INSPECTION AT 1899 SCOTT ROAD, SPRINGFIELD, OREGON Dear Mr. Christensen: At your request the Springfield Building Division made a housing inspection at 1899 Scott Road, Springfield, Oregon, on March 26, 1981. The findings of this inspection justify declaring this building to be a substandard building as defined in Section 1001 (a) of the Uniform Housing Code (U.H.C.). Therefore, any attempt to repair this building will be governed by Section 104 (b) of the Oregon State Structural Specialty Code (O.S.S.C.). This section states that any additions, alterations or repairs must conform to that required for a new building or structure. Those general requirements are listed below: Structural Specialty Code (S.S.C.) 1. All rotted and deteriorated wood must be replaced. The extent of this cannot be determined until all underfloor structural elements are exposed. 2. All lumber, plywood, etc., must be graded and stamped by an approved ,!gency (Section 2505, S.S.C.). 3. There must be a muumum of 18" clearance from the ground to all joist or sub- floor and 12" for all beams (Section 2517 (c) 2, S.S.C.). 4. One and one-half square feet of foundation ventilation is required for each 25 linear feet of foundation (Section 2517 (c) 2, S.S.C.). 5. All headers shall be supported by 2" trimmers (Section 2518 (g) 7, S.S.C.). 6. All habitable rooms shall have a 7' 6" minimum ceiling heat (Section 1207 (a) S.S.C.) . 7. Rafter and ceiling joist must be of sufficient size to carry the load and spans (Section 2518 (h) 2, S.S.C.). 8. Windows shall be of a size and openable area sufficient to provide light, venti- lation and emergancy egress (Section 1204, 1205 (a) S.S.C.). Oreqon Plumbinq Specialty Code (P.S.C.) 1. Gas, water, drainage and vent piping shall be replaced to' meet code (Section 505, P.S.C.) . , . Mr. Neil Christensen Housing Inspection 1899 Scott Road April 7, 1981 Page 2. Oreqon Electrical Safetv Code (E.S.C.) 1. The house must be totally rewired except for the service (Section 110-8 E.S.C., and U.H.C. 701). 2. Properties for sale, lease, or rent shall be wired by an electrical contractor (Section 22.110 (b) E.S.C.). Please be aware of the fact that the above list represents only the major items or general categories where repairs are necessary. If you decide to proceed with the project, it will be necessary for you to submit two sets of construction plans in- dicating all work to be done. A pamphlet explaining residential plan requirements has been enclosed for your use. Before proceeding, we urge you to carefully review the scope of work required. It is our experience that projects of this sort often , tend to appear smaller or less substantial than they really are. All permits must be obtained before work starts and all work shall be inspected be- fore a Certificate of OCcupancy will be issued. If you have any further questions, please contact the Springfield Building Division at 726-3753. Sincerely, "/11~ ~./-,~ Marion JOhns" Building Inspector Enclosure MJ/ch 1001.1