Loading...
HomeMy WebLinkAboutPermit Building 1990-4-30 5~ .. RESID~T1AL.. ," APPLICAT.PERMIT 22 North 5th Street Springfield, Oregon 97477 Building Division 726-3753 Job Location: If 4 f A8oe8oors Map H ,yfj.t Subdivi8ion: L,<)('Ii A-f),e /f--i Q.mSl': /...nc.iL.w~A./ ,dcr 1./, ,P tH'rtC/ 'p'1U:, r'r/UU-, / 0#2-..._ /.:,~'~.:- 9/.J-.~ 91'1-6;;.-. Address: I' City: E'-l4~'('/~ ; l QNmJ n Additicn o Remodel n ~robilR Homa Phone: Zip: 'L . J } j Q pe8<;ribe f,'ork: /YbOd4. ,t"t1I'f e;u.r, ~u..p &)'IC"(...~ 5--fI"Vnyt/ld " . . ' ,;23.-('LfO au.I~: 'S....._ flo'C' P}!J.! " c1/ " 00 "If 17V~.- , Siqr.ed: ,. ~o. 7l~pr; Date: Addre~~ ',Li~c. iF Bldrs Board Rez. )I1u~ L" ~, <././497 3?/J1' ~._ Date of Application Contractors General ,c/ZA.;;((? cy' \n,.'<., 4q 90 I Plumbing ~ "/.VIA.' PI",I;( j,J~ I Hechanical ,Su..v hC/r<:;~ q' I qectrical k!4-/flh ,f'JyO(,vV 1,).30 u.J, 2~'7' I Suoe"","'Sing Electr:i-cian ~,h...h. ~M, Cf!LI.C_S It is ths l'BSponDibitity of ths permit ,{,ldsr to 866 that all inspections ar6 made at thB propsr timc~ that oach .:ddrs8o is readab~6 [rom the street, and that th6 permit oard is locatBd at thB [flOnt of th8 property. I ABuit.dirtg Di,uidor. appl'ot.'sd pt.an B.halt remain on thB BuiLding sits at aLL times. pnOCEDURE FOn INSPECTION RE:QUEST;CALL 726-3769. (recorder) state your City designated job number, job addrc{SS' type of in3pec~ic'l 1'aqucstcd ar.d when you win be ready for in8pcction, Contractors 01' CMners name and phone numbC1". Requssts re aived before 7 :00 C':'I :.,'iLl. be made the same day, requests mads. a~~er 7~OO ,am wiL'L be rrrule the next :.JOrking daY'fT~'50 , Your City Doaigr.ated Job Numbs1' 10: V{W VaLue ~ I RLffl!-f.7"PP' T"l.1l."2pf!ticn:<l D. SITE INSPECTION: To be /mde after excavation, but prior to set up of forms. 0, UNDERSLAB PLUMBING, ELECTRICAL & MECHA,VICAl:: To be made before any work is .::ovcred. r7:Y'fi)OTING & POUNOATION: To be "",de ~ ~fter trenches are excavated and forms are erected, but prior to pouring ccncrete. . . ~DSRGROUND PLUMBING; SEWER. 'W.1TE'1 ~ DRAINAGE: To be rrKlde prior to fiL- l ir'.g trenches. D, UNDERPWOR PLUMBING & MECNANICAL: , To bs made prior to inatallat'Lon of 11001' insutation 01' decking. o o o D POST AND BEAM: To be made prior to installation of fLoor ins~Lation 01' decki,,". ROUef/ PLllM8IlJG. ET,ECTRICAL & MECH- ANICAL: No lJOrk is to bc covered .ur.til these inspections have beer. made and approve'::. . FIREPLACE: Prior to p7.acir'.(J facing materials and before framing inspec- tion. FRAMINC: Must be requeDted after approvaL of rough pLwr.bing, eLectri- caL & mechanicaL. A U roofing bracing a chimneys, et.::. must be . compLeted. No work is to be con- ., cealed until thiD inspection has ~ bG~n made and approved. O INSULATION/VAPOR BARRIER IIISPECTION: To be made after all insuLation a.",d ", required vapor barriers are in place ,:' " but before any Lath, gypslDn board 01' . wU covering is applied, and before . ~y inauZation is concealed. D DRYWALL INSPECTION: Ta be made after aU dryuall is in place, but prior to any taping. O MASONRY: Steel location, bond beamD, grouting 01' verticals in accordance with U.B.C. Section 2415, O WOODSTOVF.: After installation is ccmpleted. O CURB & APPROACH APRON: After forms are erected but prior to pouring aonorete. G :;;{DEWALK & DRIVEWAY: For all con- crete paving within street right- pf-ux::.y, to be made after a7.l exca- vating complete & form work & ~ub- . base mate1'ial in place. O PENCE: When complG-te -- Provide. gates 01' movabLe sections through P.U,E, ' [0' ~.~~ Rcce:pt ,if (') - ~fLh ) / +-.3i j -C./( ) Expires 'Ohnnp '..7.,;1.- 91 /Af1;-,C,"is't-Cj.. 7<17- J.f:lSb .:7 <:j1.~ \P .;)..n.d. j'Z,c.14Y~ ~y'-l--f%ZV DEMOLITION OR MOVED BUILDINGS :=J Sanitary 8e1Jer capped at p~op~rt~. lir.e =:=J Septi.:: tank rr..u:rped and fi L Le~ fJi th gra~6l ---, Final. - rfhen above items are ccmpLeted ~ ar.d when demolition is compl.ete 01' stru~- ture moved and premises cLeaned up. I Mobile Homes ~Ocking and Set-~p ~umbing connections -- scwer and wa~6r ~ctricaL Connection - BLocking, set-up ...f:::f and plumbing connections rrr-,st ce approved . beforc requesting elec~ricaL inspec~ion ~ icaessory BuiLd:i..ng -:l ~l - AfttJr p:Jrches, skirting, decks, ~tc. are completed. o All project conditwn8, such as the in.stallation of street trees, co,o;-rplation of the required Landscapir.g, etc., must be satisfied beforll ths BUIWING FINAL can be 1'equestad. o FIliAL PLUMBING o FINAL MECHANICAL o FINAL ELECTRICAL o o FINAL BUILDING: The Final Building Inspection must ba 1*squeotod after ths FinaL PLumbina ELectrical, and MQchar.ical Inspectiono hq,va been made and approved. 'ALe MANHOLES AND CLEANOUTS IIUST BE ACCESSIBLE, ADJUST/tENT TO BE MADE AT NO COST TO CITY I Pa~8 1 of 2 ....l:/.. " I I I I I I I I , I JOB .NO,Y.Orl.fX.{J6 SOLAR ACCE~S REQ,- I ::onc: l A\t~J Occupanc~ G.\< ~ Lot Sq. Ftg. " LOT TYPe " I Lot Faces - I Setbacks ~ of lot Coverage Interior I P,L, /House Caraqe # of Stories Cornel"lNOl'th Total Height Panhandle ,lEast /' ISouth I Topography = CUI-de-sac West I I lITeM l1-bin I CcPaae I CarOOl't I Acces80ru , SQ,FTG I I I Is, D.C. TOTAL VAWe (VC(,UC) 1,5 " Building Permit State SW>charge Total Cha:-ges lITeM ,_.."" ~ \--\ I Residential (1 bath) I Sani tary Sewer> NO, I I I I I_I l~n\ Plumbing Pem t State Surcr.arge Total Charaes ! ITeM I..... 00. I NO., i;_. \V\ \---\ I New/e"tend Circui ts I I I I I_I " Ele~trical Permit State Surcharoe Total Chtnoc;ee I ITEM I Furnace !!TU' S E:r:haus t Hood Vent Fan IlIoodstove I Permit Issuance Me::hanical pernrit Stato Surcharae . TntnZ r.haPaRn -- eNCROACHMENT -- I Securit~ DepOsit I stor~e I Main tena~e Permit Total Chat'CIoS I CUrbcu; I Sidewa lk ~ll/' I Pen:::e I Electrical Lobel IM8Qi-O. ,., ,,"~ I TOTAL AMOUNT DUE: ~ x Value ,-)J('/1 jq I 1/,1f4~ I ,WA) 4/ A I...~~ 10 .CUa ' 'aq,m 1.4-1< SOq 0' NO, I CHARGE I ,\Sml I I ~n,CDI I t ~.C)() I ~D .DO I 11)l),CO I I ~.SOI . '::::i. ..... IVL~.~)I ' '\~R,Q) i I I I~CUI 0n.OOI \",SOI I~ .S)l, FSe I CIIARCe I I I I I I I I I I \ --.. I I~\C\.)', I I I I I "J I ~\llGf, (2) I V~ ~c; I I I I I ~~<l--f ./l;5 11'0.1S I 3. c9.-. ') I Lon/, '7LJ I Fee Fee L-COG",/ T-dpe/Cor.et: ... Bedroom.:~ . ~ I Enel'q}/ Sources rP.....,... - I I I Heat tc:" -"" I Access. I I Y Water Hp.atp.l' 119"':' Range I -,--FireVlace I : : Wood" to"e Tlloe Fees Building Value & Permit This permit ia granted on the express condition that the sdid construction shall, in all respects, conform to the Ordinance adopted by the City of Spl'ingfield, including the Zoning CTdinance, regulating the COllotl'u.:tion and use of buildings, and may be suspended or revoked at any time upon vie. lanon of any provisions of said Ordinances. IPlan Check Fee: _ ,. Ivate Paid: \ \ I", IReceiPt #: Il_ I S<gned: I '\ J Plumbing Permit No pel'Bonphall construct, install, alter or change any new or existing plumbi~ 01' drainage system in whole 01' in part, unless such person is the legal possessor of a valid plumber's license, except that a person may do plumbing work to property which is owned, leased 01' opel'ated by the appli- cant. . , Electrical Permit Where State La1J requil'es tr.at the electrical. wrk be done by an Ele~trical Contractor, the electrical portion of this permit shall not be valid until the label has been signed by the Electrical Contractor. Mechanical Permit ,~il'1 ~QD 4-9_0,C{( ) 00.. I HAVE CAREFULLY EXAMINED the completed application fOP'permit, and do hepeby certify that all info;omation hereon is true and corl'cct, and I further certify that any ar.d all lJOrk perfornJed shall be done in accor- dance with the Opdinances of the City of Springficld, and th& Ur~s of the State of OregDn psrtaining to the work described herein, and that NO OCCU- 'PtlNC'z' will ue (lade 0/ any structUl"e without permission of the Buildlng Di- vision. I further certify that only contr>actorB and ew,plDyees who are in compliance with ORS 701.055 will be used on this project Xn3~ ~ ~ -<\- ~.tlo Date