HomeMy WebLinkAboutCorrespondence ENG 12/29/2005
12/29/2005 THlI 09:59 FAX 541 687 0739 GOEBEL ENGINEERING
I4i 001/003
.
.
Goebel Engineering & Surveying, Inc.
Engineering Surveying Planning
310 GaJlield Street Eugene,Olll9on 97402
Phon.: (541) 687-l1542 F",,: (541) 687.Q7a9 E-mail: sCD!t@9eseugene_com
FA-CSIN1L6
TO: Jim Donovan
COMPANY: City of Springfield
FAX NO.: 728-3889
PROJECT: Legacy Estates
GES NO.: 02414-2004-C
FROM: Pamela Goebel
DATE: 29 December 2005
PAGES: 3 (IN(UlDINGo a:I'VQ)
Date Received: 1-z.-2-Cj. 05
Planner:- -0D____________
I of 4- p~
PII!:'lI'l.e no-t:ih ..~nJII:T" if t;his i:TClI'I{miHion if inGomplcrte err to in~d.loL'df:.j(ln in~. Thank lIou.
REMARKS:
Jim_ WV:re working on our final checklist items for this project_ As we discussed; we plan to turn it all in at one
time and. would prefer to have it all earreef (as much as possible) the first time,
Attached is our first draft of the -condition" for wellh....d protection_ Could you please review at your .,..,.Iiest
convl!llience and give us your feedbaclO
THANKSI
M:\pcrs-DiM - C\Corey\Legacy Estates {024i4)\1 F(l,(~s\C;w\Clty - Oono...an r.'(C!~.wpd
12/29/2005 TEll 09:59 FAX 541 687 0739 GOEBEL ENGINEERING
@002/003
.
.
Goebel Engineering & Surveying, Inc.
Engineering Surveying Planning
310 Garfield SIr...1 #30 Eugene, Oregon 97402
Phone: (541) 687-0542 Fax: (541) 687..0739 E-mail: sc:ottlB)ceseuaene.com
APPLICANT'S PROPOSED
CONDITION OF APPROVAL
for
Legacy Estates
Tentative Subdivision
(SUB 2005-00008/00047)
PROTECTION
for
. ADJACENT WATER WELL
submitted to
City of Springfield
Dccemhe:r 2005
i..
12/29/2005 THU 09:59 FAX 541 687 0739 GOEBEL ENGINEERING
~ 003/003
.
.
The applicant shall protect the existing water well, located on Tax Lot 300 of Assessors map 17-
03-24 31. All improvements and activities shall comply with state rules relative to wellhead
protection.
Relative Oregon Administrative Rules (OARs) are as follows;
1. OAR 690-210-0030: No sewer pipes (storm or sanitary) shall be placed within 50' of
the welJhead.
Lots 5 and 8, as well as the right-of-way of North 16th Street, are encumbered by this rule.
A 50' radius wellhead protection easement shall be shown on 5the final plat and on all
engineering documents.
2. OAR 690-210-0250: TheweU casing is to be at least 12" above adjacent ground.
All new construction associated with this subdivision shall be graded so as to drain
surface water away from the well.
3. OAR 690-21-0050: The existing well shall not be altered in any manner as to alter
(the) well casing integrity. The weD easing is to he securely covered to prevent any
foreign substance from entering the well.
This condition does not require the applicanllo reconstruct the well to comply with this
rule. However, the applicant is restricted from constructing any improvements (public or
private) that would introduce any foreign substance from entering the well which might
eontHminHtc the ground water.
12/29/05 THU 11:05 FAX 5417263689
CITY OF SPRINGFIELD
Il1J 001
.
.
.
,
RECEPTION OK
TX/RX NO
CONNECTION TEL
CONNECTION IV
ST. TIME
USAGE T
PGS.
RESULT
*********************
... RX REPORT ...
*********************
6438
541 687 0739
GOEBEL ENGINEERI
12/29 11:04
00'51
3
OK