Loading...
HomeMy WebLinkAboutBuilding Correspondence 1988-10-21 (2) . - t,:' I.,;);;.' ~.~ ~ . ~~'~':" ,.~.... . '-"f>- .tfJ....)~"i:J;lIi'lr-j=I:1I...J:I=l.tt.h.1 225 FIFTH STREET SPRINGFIELD, OR 97477 r--. , -'-" ,@ ( .., , " l ~ .J.f: 8 Hoii> il~q l~ICE --E.tL. .gbjj .\RETURNf - ~~:: _ --:J -.--/ 11,1"1",1,1"111",,1,1,,,11,,1,1,,1,1,,,11,101,,1' \ ~, " 1\ '., !'V I .;. ',r -,.. 'r . ~ "',:,.. " " .~;"DM~..~i'o~mp~'.t.!lt.~m. 1 d 2 h d lid d 1 1 3 ;;:tEN ~)!( C an w en a d tlonal lervlce, are del ra . 8n camp ate tern. and4. Put your addreu In the "RETURN TO" Space on the revene Ilde. Failure to do this will prevent thl. cllrd from being returned to you. The ,.turn r&Cflto! f.'!.Y'!~ILp~n"~.u th~ 't,!"A.O.,f .thR.r:lAII2D. delivered to and the deteat dellVrV, For additional fa" the fOllowing lervlces .r8 available. Consult POStmaster for fees and check box es) for addltlonel lervlce(l) requested. 1. .J{/){Show to whom dellver8<l, date, and addr.....'. address. 2._ 0 Restricted Delivery t (Extra charl/!) t t.{Extra charge) t .:-;.:!ssed to: 4. Article Number -:;-- '. ,,",j Ann Mackinn3n 147 Treehill LOOD Eugene, OR 97405 P 716 420 208 Signature - Addressee Type of Service: o Registered Ie Certified o Express Mall I Always obtain signature of addressee or agent and DATE DELlVEREQ. 8. Addressee's Address (ONL Y if requested and fee paid) o Insured o COO I~ 6, X Signature - Agent 7. Oate of Oelivery PS Form 3811. MaI. 1987 ... US.Q.P.O. 1887.178-268 DOMESTIC RETURN RECEIPT -.. /1 /' I 1 , DEVELOPMENT SERVICES ADMINISTRATION PLANNING I BUILDING PUBLIC WORKS METROPOLITAN WASTEWATER MANAGEMENT 225 FIFTH STREET SPRINGFIELD, OR 97477 (503) 726-3753 CERTIFIED LETTER October 2], 1988 Mary Ann Mackinnon '147 Treehill Loop Eugene, OR 97405 Subject: Occupancy Inspection at 1162 Gateway Loop Springfield, Oregon. Proposed Use: Night Club/ Restaurant/ Arcade City Job #880896 At your request, the Springfield Building Safety Division recently conducted an inspection of the building(s)' at the above address. The purpose of the inspection was to determine the suitability of the building(s) for the proposed use as indicated. Based on the"proposed' occupancy, the existing conditions which are mentioned below do not meet the minimum Building Safety.Code requirements. Corrective measures must be taken prior to .occupancy to install, repair; replace or modify the following items in order for the building to conform to applicable safety codes: Structural Specialty Code and Fire & Life Safety Regulations (SSC) Allow. Bldg. Area . SSC505 1. The building shall be divided into two separate buildings by a two-hour fire resistive area separation. wall in order to reduce the building area to the maximum allowed for the proposed occupancy group and the type of construction used. The existing concrete dividing wall may be used for this purpose if the opening between the two areas is protected with a fire door having a minimum 1-1/2. hr. fire resistive assembly. Automatic Sprinklers . SSC506c 2. The entire building shall be provided with an approved automatic fire sprinkler system. .When serving. more than 100 sprinkler: heads, the system shall be supervised by' an' approved central proprietary or remote. station .- service' or a local' alarm 'which will give, an audible :signal at a constantly ~ttended location as .~!,prov<:d by the City Fire Marshal. Mary Ann Mackinnon October 21, 1988 Page 2 No. of Exits Req'd SSC3303 3. The number and location of required exits shall be determined by the actual floor plan for each proposed area. Exits shall comply with the requirements of Chapter 33 of the Structural Specialty Code. When two exists are required for a given area, they shall ,be separated by a minimum distance equal to one-half the diagonal measurement of the area or room being considered. Mechanical Specialty Code and Mech. Fire & LIfe Safety Regulations (MSC) Ventilation SSC605-1005 4. All habitable areas shall be ventilated by means of exterior openings having an aggregate area of one-twentieth of the floor area for the area being considered, or a mecanically operated ventilation system shall be provided which is capable of supplying a minimum of 5 cubic feet per minute (cfm) of outside air with a total circulated of not less than 15 cfm per occupant in all portions of the building during times the building is occupied. . Electrical Specialty Safety Code (ESSC) Elect. Sys. OK ESSC-OAR8l4-135 5. The existing electrical system within the building appears to meet the requirements of the Electrical Specially Code for the proposed use. Any modifications or extensions/additions to the existing system shall conform to the current minimum electrical safety standards, and shall be installed only with proper permits and inspection approvals. Plumbing Specially Code (PSC) Sanitary Facilities SSC510 6. Sanitary Fncilities shall be provided in accordance with Section 510 and Table 5-E for requirements based on occupant load in the building, and Chapter 31 for handicapped access requirements. Based a the theoretical occupant load of 791 people, a mmImum of ten toilets and six lavatory basins shall be provided, equally divided between males and females. At least one toilel and lavatory shall meet handicapped requirements in thl' facilities for each sex. Also, a minimum of one drinking fountain shall be installed. Site Development Requ~rements 7. Offstreet parking shall be provided as required by the Springfield Development Code based on the proposed use for each area of the building. A total of 112 additional parking spaces (158 total -46 existing spaces) shall be provided for the proposed combined uses of the building based on the aUached theoretical schedule of uses. Parking spaces at the site Mary Ann Mackinnon October 21, 1988 Page 3 shall be adequate to accommodate the parking requirements for all facilities which are open for business al any given time. Please coordinate this requirement and any other requirements for the site, such as handicapped parking, landscaping or other sile improvements with the City Planning Division. Due to the nature of the proposed uses and the si7.e of the building, plans for the modifications to accomplish your proposal shall be prepared by a professional architect or engineer who is licensed by this State. Complete plans shall be submitted to this office for review and required permits shall be obtained prior to commencing any work ori the facility. If you have any questions or need clarification of the above requirements, please call the Building Safety Division at 726-3759. Sincerely. ~r;f~ Don Moore Structural Inspector CC: Dave Puent, Building Official Mike Hudman, Fire Marshal Greg Mott, Development Code Administrator Cindy Harmon, Permit Coordinator ProPOsal to occupy preperty at 1162 Gateway LooP for: NIGHT QUB / RESTAURANT / ARCADE by Mary Ann MackimOl1 Prooosed Use Floor Area OCClnant Loa:j FRONT " Total 13200 s.f, Restaurant 30)) 200 peep Ie Kitchen +or- 1CXXJ 5 Office .1320 13 Arcade 16m no Lobby / Lounge / Circulation 6280 -D- REAR Total 9200 s.f, Nightclub seating 7300 487 Dance Floor 12CX:l -D- Bar 300 2 Misc Cirulation 400 -D- Total Area 22400 s,f. 791 Total