HomeMy WebLinkAboutCorrespondence ENG 9/24/2010 .. ',- . . L1MBIRD Andrew From: Sent: To: Cc: Tina Guard [tguard@bhengineers.com] Friday, September 24, 2010 12:48 PM GORDON Gilbert; rnossaman@bhengineers,com L1MBIRD Andrew; BCO; MCKEE Bart (SUB); 'TEMPLIN Rebecca'; 'Ladd Boyce'; 'HIGLEY Scott'; GERARD Alan RE: Gateway Mall - Cabela's fire hydrant Subject: BHE loves this idea, as it makes it super easy for us, @ Thanks! From: GORDON Gilbert [mailto:ggordon@ci.springfield.or.us] Sent: Friday, September 24, 2010 12:09 PM To: 'tguard@bhengineers.com'; rnossaman@bhengineers.com Cc: UMBIRD Andrew; BCO; MCKEE Bart (SUB); TEMPUN Rebecca; Ladd Boyce (Iaddb@subutil.com); HIGLEY Scott; GERARD Alan . Subject: RE: Gateway Mall - Cabela's fire hydrant Tina and Ryan, Thanks for waiting. I talked to Paul Esselstyn (one of our operations battalion chiefs), Ladd 80yce and 8art McKee with SUB Water Division. Ladd and Bart are proposing to completely remove that center fire hydrant instead of relocating it. Since water flows are in the 2,500 gallon per minute range at 90 psi or better with only a 10 psi residual drop provided by 12 inch fire lines and fed by three different sources, the' two existing fire hydrants on the northwest and southwest corner of Ashley's/Cabela's are sufficient. The furthest hose lay reach is 300 feet, well within the maximum length allowed by code. Also, since this 54,714 square foot anchor building is sprinklered and Type II construction, fire flow requirements are for 1,500 gpm per 2007 Springfield Fire Code Table 8105.1 and sections 8105.3,1 and 8105.3.1.1. Therefore, SUB Water Division's proposal for removing the central fire hydrant in front of Ashley's/Cabela's instead of relocation is acceptable with Springfield Fire Marshal's Office. Gilbert R Gordon Deputy Fire Marshal Springfield Fire and Life Safety 225 Fifth Street Springfield, OR 97477 Phone: 541-726-2293 E-Mail: QQordon@cLsprinQfield.oLus From: Tina Guard [mailto:tguard@bhengineers.com] Sent: Wednesday, September 22, 2010 11:28 To: rnossaman@bhengineers.com; GORDON Gilbert Cc: UMBIRD Andrew Subject: RE: Gateway Mall - Cabela's fire hydrant Gilbert, We need to include this relocation in an addendum that we need to issue to bidders this week, DatElI~eceived: r2 ~/)ol" Planner: AL 1 . . . '. Thanks, Tina L. Guard, PE, LEED" AP Civil Project Manager Batzhiser & Hubbard Enqineers Mechanical - Electrical ~ Civil - Energy - Lighting - Surveying - Commissioning - Sustainability 100 West 13th Avenue, Eugene, Oregon 97401 (541) 686..a478 fax (541) 345~5303 From: Ryan Nossaman [mailto:rnossaman@bhengineers.com] Sent: Wednesday, September 22, 2010 11:26 AM To: ggordon@ci.springfield.or.us Cc: tguard@bhengineers.com; 'UMBIRD Andrew' Subject: FW: Gateway Mall - Cabela's fire hydrant Hi Gilbert, Just checking with you to see if you've had a chance to review the hydrant relocation and if you need any further information? Thank you, Ryan Nossaman Civil Designer Batzhiser & Hubbard Enqineers Inc. Mechanical- Electrical - Civil- Energy - lighting - Surveying - Commissioning - Sustainability 100 West 13th Avenue, Eugene, Oregon 97401 (541) 686-8478 fax (541) 345-5303 From: UMBIRD Andrew [mailto:alimbird@ci.springfield.or.us] Sent: Monday, September 13,2010 4:17 PM To: 'Ryan Nossaman' Subject: RE: Gateway Mall - ,Cabela's fire hydrant Thanks Ryan, as requested I have forwarded this info to Gilbert Gordon of the Fire Marshal's office. Andy From: Ryan Nossaman [mailto:rnossaman@bhengineers.com] Sent: Monday, September 13, 2010 4: 15 PM To: UMBIRD Andrew Cc: tguard@bhengineers.com Subject: Gateway Mall - Cabela's fire hydrant Andy, Please refer to the attachment and could you please forward this to the Fire Marshal that has been assigned to the Cabela's project? We are in the process of coordinating the proposed hydrant re-Iocation with SUB. This location is being considered because of the close proximity to the existing utility easement. Please review and comment. 'Thank you, Ryan Nossaman Civil Designer 2 Date Received: )h~/J?'o Planner: AL