Loading...
HomeMy WebLinkAboutMiscellaneous PLANNER 9/17/2009 . . Site Review Submittal Application (Revised September 15,2009) Site Review Narrative Afiya Apartments Map 1703 35 41 Tax lots: 4600,4700,4800,4900 (Subject Property is Tax lot 4700) 1082 Main Street (Address of Subject Property) Springfield, OR Project Description Afiya Apartment, Inc is proposing to develop a three-story, multi-unit supportive housing complex. The project is funded through a Federal HUD 8 I I program with additional funding through the City of Springfield and Oregon Housing !Ind Community Service. ShelterCare, Inc. is the sponsor for the project and it will be managed through ShelterCare's Brethren Housing program, which currently occupies part of the site. The new building will provide sixteen (16) I-bedroom affordable units that will serve low income individuals. The building will include amenities including a multi-purpose room, resident's game room, shared laundry, and management offices. Site Description The project site is located on Main Street, adjacent to The Springfield Church of Brethren (SCoB) and the existing Brethren Housing (BH) residential units and offices. It is zoned Mixed Use Residential (MUR). The proposed building is located on tax lot 4700, whose configuration will be adjusted through a concurrent Property Line Adjustment Application that will facilitate future re-development ofthe remaining parcels of the site. Access to the re-configured site will be guaranteed via a shared private driveway by an irrevocable joint use! access agreement. All tax lots (Tax lots: 17-03-35-41 parcels 4600, 4700, 4800 and 4900) will continue to be owned by SCoB. This parcel will be leased by Afiya Apartments, Inc. from the SCoB for a minimum of 50 years (with 25 yr extension). Based on the new lot size of .28 acres, the density of the project will be 56.9 units per acre. The project site is bordered by a combination of existing commercial, institutional and multi-family uses to the east and west and single-family homes across a public alley to ihe north. It is flat with several significant trees that will be removed as part of the project. It does not contain any jurisdictional wetlands. The site is served by public sanitary line and overhead electrical power in the alley, as well as public water and storm lines in Main Street. Review Processes Based on land use requirements for MUR zone, site characteristics and proposed features of the project, the following Type II applications and permits are necessary for development approval: Site Review Property Line Adjustment Tree Felling Permit ODOT Right of Way Driveway Permits Applicable Development Standards Site Review Design Criteria and Standards Following is a brief description of how the proposed design for the project addresses the Site Review and Development standards of Chapters 3, 4, and 5 of the current Springfield Land Use Code. II \11/ ,,1 _ Date ReceiVeq;~ . Planner. MEN! Afiya Apartments - Site Review Application Submittal Revised 9/15/09 Page I of8 . . Section 3.2 600 Mixed Use Zoning 3.2-605 Establishment or Mixed Use Zonine: Districts The development site is composed of a single tax lot parcel that is zoned Mixed Use Residential (MUR) which is intended where a mix of medium and high density and commercial uses is intended. 3.2-610 Schedule orUse Catee:ories Our proposed use of 100% multi-family residential is a permitted use within MUR zone. 3.2-615 Base Zone standards per Table 3.2-615 and 3.2-215 Standard Requirement Project Notes Proposal Min. Area 4500 sf min. 12,250 sf Min. Frontage 45 ft. min. 0 Access guaranteed via private driveway by an irrevocable joint usel access agreement as specified in 4.2-120A Max Lot 45% max. 44.1% Based on Building Footprint of 5397 sf Coverage Front Yard 10 ft. min. 5 ft. Requesting an adjustment to allow front entry porch to extend five ft. into the front setback for 50% of the building frontage. Rear Yard lOft. min. 10 ft. Side Yard 5 ft. min. 5 ft. or greater Max. Bldg 59.4 ft min. 61 ft. actual SSB Solar Set Back Calculation Based on 6: 12 roof with Height SSB from ridge at 35'- 9": residential PL SSB = 2.5 x 35.75 + (90/2) ~ 75 ~ 59.4 ft. min. 3.2-625 Mixed Use Development Standards - General A. Buildine: Desie:n Standards - Multi-family standards prevail B. Buildine: Orientation and Setbacks -.Multi-family standards prevail C. Weather Protection Not applicable D. Landscapine: and Screening Multi-family standards prevail E.. Street Connectivity Not applicable F. Neie:hborhood Compatibility I. Architectural compatibility: The gable roof form, lap siding, window proportion and trim of the building are residential forms and materials that can be seen in the existing LOR neighborhood. 2. Lie:htine:: Lighting fixtures visible from the LOR uses are mounted on the building at 12 ft. above grade and are low cut off so as not to produce glare on adjacent properties. 3. Site Obscurine: Landscapine:: The LOR lots adjacent to the property have existing site obscuring fences or accessory buildings facing the alley. Trees will be planted in the landscape islands on each end ofthe alley parking. 4. Mechanical Equipment: Mechanical Equipment located along the alley is screened by landscaping as required. Afiya Apartments - Site Review Application Submittal Revised 9115/09 Page2of8 . . G. Pedestrian Amenities Not applicable 3.2-630 Mixed Use Development Standards - Specific to MUR per 3.2-630 (Cl Standard Requirement Proiect Proposal Min. Residential Use 80% 100% Min. Density if all residential 20 units/ acre 56.9 units /acre Max. Density None 3.2-240 (Multi-family standards) Meet all Complies ( see below) 3.2-240 Multi-Unit Desil!n Standards Building orientation: The project site does not have direct frontage along a public str~et. However, the shared driveway access is designed to function as a private internal street. The lobby and courtyard entrances for the building are oriented toward this internal street. Building Form: The proposed building meets the criteria for building form standards as follows: . Continuous Horizontal Distance Each of the facades of the building is less than the maximum 120 lineal feet. The longest fa9ade, which faces the alley and the LOR zone, is 89 ft. long. . Roofs The proposed roof is a gable form with a 6: 12 pitch. Overhangs are 18-24 inches deep. . . Windows and Doors on front fa9ade The overall wall area of the front fa9ade is 2170 sf and the breezeway, window and door area is 375 sffor a total percentage of 17.2 %. Doors and .windows on all facades will be trimmed out with a 4-inch wide trim as shown on the elevations. . Garages Not applicable . Exterior Design Features The exterior of the building uses bays (floor plan extensions of 2ft depth) and off sets and breaks in the roofto articulate the facades. In addition, the siding pattern varies to provide texture, detail and color accents. Transition and Compatibility between Multi-Unit and LDR Development: The proposed project is adjacent to LOR only on the northern property line of the site. All other adjacencies are Community Commercial. . Front Yard Setback Not applicable . Buffer Between multi-unit development and LDR property line A buffer of25 ft. along the north property line does not apply because there is a public right-of-way (the alley) between the project site and the LOR zone. Afiya Apartments - Site Review Application Submittal Revised 9/15/09 Page3 of 8 . . o Building Height: The primary building is 32'-3" to the mid-point of the roof. The face of the building is 45 ft. from the LOR property line, including the width of the alley. o Maximum Length The primary structure is 45 ft. from the LOR property, but is only 94-5" ft. in overall length. Storage: . Bulk storage areas are provided for all the units, either near the entry or within the unit. Each storage area encloses at least 184 cf and provides sufficient space for individual, secure bike storage for each dwelling unit, as well as the 112 cfbulk storage required by the standards. The trash and recycle area is located adjacent to the project site and will be shared between the existing church and residential uses and the new dwelling units. It will be an enclosed building facing the shared access drive or the alley. (To be determined with vendor) It is located 12 ft. from the alley right-of-way, and exceeds the 25 ft. min distance from an LOR property line. It is screened from the alley as shown on the landscape plan. The transformer is proposed in the northeast corner ofthe site, subject to SUBs approval. It will be screened with landscape as indicated on the landscape drawings. Open Space: Based on the population who will live at the project and the owner's goal to create a supportive living environment through community interaction and strengthening of social skills, we are proposing to omit private open for each of the units. Instead, we are providing shared indoor and outdoor community spaces to facilitate and promote an enhanced sense of community. The common open space requirement for the project is calculated on 10% of 12,250 sf of gross site area because the density exceeds 30 units per acre. The total required area of 1,225 sf can be a combination of yards, common open space and private open space. Not including setback areas, we are providing approximately 1,422.5 sf of usable indoor and outdoor community space on the ground floor for the residents - 16% more than the minimum required open space for a project of this density. In addition, we are providing a 265 sf recreation room on the second floor for a total of 1,688 sf of community space for residents. Landscaping, Fences and Walls o Area The landscape design consists of a balance of lawn, planting beds (ground cover, shrubs and perennials), and trees. Of the 3725 sf of pervious area, approximately 75 % will be planting beds consisting of ground cover, shrubbery and trees. o Planter Strips Not Applicable o Street Trees Not Applicable o Fences Afiya Apartments - Site Review Application Submittal Revised 9/15109 Page 4 of8 . . There are no fences proposed in the front yard of the project. A new six ft. site obscuring fence between the existing fence on the east property line and the building will be installed to discourage cut-through pedestrian traffic from the alley. Irrigation . A permanent irrigation system will be installed as described on the Landscape drawings. Pedestrian Circulation: . Continuity An internal sidewalk network connects the primary building entries, parking, trash enclosure and public right_of-way. . Separation Internal sidewalks are all separated from building edges by more than the 5 ft. minimum. . Connection to Street Both the courtyard and primary building entrances are connected to public right-of-way via the sidewalk adjacent to the proposed driveway. . Surface Treatment All walking areas connecting the building to the auto parking, the trash enclosure and the public way are concrete or striped asphalt. Parking: . Location The new vehicular parking is located to the side of the building along the alley. . Lighting Lighting of the new alley parking will provide the minimum number of foot candles of illumination needed for safety in the parking area. Fixtures will be mounted,at a maximum of ]2 ft. high on the face of the building and will be shielded to prevent glare and reflection on the LDR properties. . Planting Islands In order to make efficient use ofthe site, we are proposing nine parking spaces between the two planter areas instead of the eight maximum. . Visual screen between parking and living are windows The area between the building and the parking areas meets the minimum 6 ft. in width and will be planted with a combination oflawn, ground cover, shrubs and trees. Vehicular Circulation . Connection to Public Street The shared access drive connects to both Main Street and the alley. 4.2-100 Infrastructure - Transportation 4.2-120 Site Access and Drivewavs Access will be provided through a shared driveway via an irrevocable joint use/access easement between Tax lots 4700 and 4800. Both parcels are owned by the Springfield Church of Brethren. The driveway will meet the design standards set forth in Table 4.2-2 and the City's Engineering Design Standards and Procedures Manual. ' 4.2-130 Vision Clearance A ] 0 ft. x ] 0 ft. vision clearance area is located at the intersection of the driveway and Main Street. Afiya Apartments - Site Review Application Submittal Revised 9/15/09 Page 5 of 8 . . 4.3-100 Infrastructure - Utilities 4.3-105 Sanitary Sewers Sanitary service for the building and the new trash enclosure will be connected to the existing public sanitary sewer line in the alley. 4.3-110 Stormwater Manal!:ement The project will create approximately 8,525 sf of new impervious surface (building footprint, sidewalk and new parking) on Tax Lot 4700 and impact an additional 7500 sf of existing impervious surface on adjacent tax lots. The existing driveway and parking does not meet current design standards for stormwater quality. Our design strategy is to: . re-grade and re-surface the existing impervious area that the project is impacting so that it can be collected and treated through mechanical means (filtered catch basins) before it enters the public storm system, . collect and treat 100% new non-roof area (i.e. alley parking) through vegetative means before it enters the public storm system, and . allow the roof area drains to enter the public storm system without treatment, as is allowed by City of Springfield's Stonnwater Manual. 4.3-115 Water Quality Protection Not applicable to our site. 4.3-120 Utility Provider Coordination Coordination with SUB and other franchise utilities are currently in process. The proposed locations of the electrical transformer is shown on the architectural site plan. It is assumed that franchise utilities will locate adjacent to the electrical transformer. 4.3-125 Underl!:round Placement of Utilities Utilities (electrical, phone and cable TV) will be place underground. We will coordinate with SUB and franchise utilities on how and where to cross the alley from their nearest overhead pole to our final transformer location. Tentative locations for utilities are shown on the civil plans. 4.3-130 Water Service and Fire Protection Service for domestic water and an automatic fire suppression system will be provided for the proposed building via a new public line located in a new 7 ft. public utility easement (PUE) within our shared access and utility easement. (Pending SUB's approval.) Only the water line is to be located in this PUE. Location of the water meter will be in the landscape area where the water line enters the new building. The back flow devices for the fireline and irrigation will be located inside the building approximately lOft. from the property line. Laterals from this new public line will be stub to adjacent lots for future re-development. Per SUB's request, the PUE will be written and recorded after construction of the waterline. 4.4-100 Landscaping, Screening and Fences 4.4-105 Landscapinl!: Landscaping is proposed for all setbacks and parking lot areas on the development parcel. Planter strips and Street Trees are not applicable to this project. Permanent irrigation will be provided for new landscape areas as shown on the landscape plan. Fourteen existing trees will be removed for the project. A tree felling permit will be submitted concurrent with Site Plan Review for ti,e trees that will be removed for the proposed project. See Landscape sheet LA-I. 4.4-110 Screeninl!: Afiya Apartments - Site Review Application Submittal Revised 9/15/09 Page 6 or8 . . Screening is provided for the shared trash enclosure, utility devices and per multi-family standards as shown on the landscape plan. 4.4-115 Fences There are no fences proposed in the front yard ofthe project. A new six ft. site obscuring fence between the existing fence on the east property line and the building will be installed to discourage cut-through pedestrian traffic from the alley. 4.5-100 On-Site Lighting Standards 4.5-110 Illumination and Heie:ht Lighting for the parking along the alley will be provided by fixtures mounted on the face of the building. They will be mounted at a maximum of 12 ft. from finished grade and shielded so as not to produce direct glare or reflection beyond the limits of the property. Additional lighting will be provided for the porch and walkways along the path of egress for the dwelling units and common spaces. 4.6-100 Vehicle Parking, Loading and Bicycle Parking Standards 4.6-11 0 Vehide Parkine: - General We are proposing a reduction in the number of required parking spaces for the project based on the abil ity to share parking between the mix of uses on the site, the demonstrated low need for vehicle parking for the residential use for similar populations, the location of an L TD bus stop at the site and the proximity of the project (6 blocks) to the EMX station. We are requesting this reduction through Director's Decision as is allowed by Section 4.6-110 A.3. See further discussion below. 4.6-115 Vehicle Parkine: Desie:n Alley parking is angled at 60 degrees per the direction at the DIM meeting. It complies with the dimensional standards of Table 4.6-1. 4.6-120 Parkine: Lot Improvements . Snrfacing The parking lot surface is asphaltic concrete with a concrete apron at the driveway approach. . Drainage The resurfaced existing parking area is designed to drain away from the building and public right of way into filtered catch basins in the shared driveway. The new parking area along the alley will drain to a rain garden at the northeast comer of the site. An overflow will be piped to the public system. . . Parking Stalls All parking stalls are equipped with 6 in. tall by 6 ft. wide wheel bumpers. They are located 2 ft. behind the stall head to prevent encroachment on to sidewalks and planted buffers. . Compact stalls Two compact stalls are proposed. They are 8 ft. x 18 ft. Disabled parking A total of 2 disabled parking spaces are provided, including I van accessible space. This meets the number of spaces required by OSSC. They have been located to serve both the church and the new residential building. A striped cross walk will be provided across the driveway to the sidewalk ramp. 4.6-125 Vehicle Number of Spaces Required (please refer to Attachment A- Parking Comparison) Atiya Apartments ~ Site Review Application Submittal Revised 9/15/09 Page 70f8 . . The attached parking comparison chart summarizes our request for a parking reduction based on a ratio of .25 spaces per dwelling unit. Column A is the total humber of parking spaces required per Table 4.6-2 for all the current and proposed new building. Column B is the number of spaces with the proposed ratio of .25 spaces/dwelling unit. Column C is the number of proposed spaces on the site before and after the project. Reducing Ratio to .25/per dwelling unit We strongly feel that, based on the population that will live at Afiya, 1.5 parking spaces per unit is excessive. First, all of the units are one-bedroom units. The Springfield Land Use Code does not make a distinction between 4-bedroom units and I-bedroom units in its on-site parking requirement. Second, the vast majority of residents cannot afford to own or maintain a vehicle. ShelterCare's experience at other residential communities similar to Afiya is that a ratio of .25 per unit is adequate for both the residents who currently live at the site and the new residents who will live at Afiya. (See Attachment A). Proximity of Bus stop and EMX Because most of the residents do not own a vehicle, they rely substantially on public transit for their daily transportation. An L TO stop (westbound) is located at the project site on Main Street for their use. In addition, the project site is located within six blocks ofthe Springfield downtown EMX station which provides frequent and fast transportation between Springfield and Eugene and soon to Gateway Mall and Peace Health Medical Center. Sharing Parking Between Uses Currently there are three existing uses on the site - residential with administration, church and a small retail outlet operated by the church. Based on current use patterns for the church, parking needs are mostly on Sunday morning and some evenings sprinkled throughout the week. These are times when the offices (for Brethren Housing and the Church) and the small retail space are closed, justifYing some. sharing of parking spaces for the highest need on Sunday morning. 4.6-150 Bicvcle Parkin!! Facility Improvements Bike parking is provided for the project inside the oversized bulk storage closet for each unit. The closet is lockable and will be keyed with each unit entry door. All floors are served by the elevator which facilitates bringing the bikes to the storage units located on second and third floors. 4.6-155 Bicvcle Parkin!! Number of Spaces Required One long term space per unit is provided for each unit as required. Afiya Apartments - Site Review Application Submittal Revised 9/15/09 Page 8 of8. . . Afiya Apartments Attachment A 7/23/2009 (Revised) PARKING COMPARISON A B C Areal Ratio No. Required No. Required No. Provided EXISTING No. Units Per Table 4.6-2 Per Zoning wi Adjustment' Residential Units 13 1.5/unit 19.50 3.25 Residential Office 475 1/200 2.38 2.38 Subtotal Residential Uses 21.88 5.625 Church Assembly area 650 1/100 6.50 6.50 Non.assembly uses 3072 1/200 15.36 15.36 Retail 285 1/300 0.95 0.95 Subtotal Church 22.81 22.81 Total All Uses 44.69 28.44 36 PROPOSED INew Residential T 1 I Units 16 1.5/unit 1 24.001 4 IComparative Total 1 68.691 32.44 39 'Requested Adjusted Ratio for Residential Units 0.25 per unit (Based on info from other projects, transit stop proximity and shared parKing between uses) ISummary of Parking at Existing ShelterCare Complexes Project Name No. of No. of Ratio Units Vehicles Brethren Housina - SDrinofield 8 1 0.13 Hawthorne ADts - Euoene 35 7 0.20 Sign Post - Springfield 16 3 0.19 ~,