HomeMy WebLinkAboutBuilding Correspondence 1978-12-14 " . . CITY OF SPRINGFIELD SPRINGFIELD, OREGON 97477 PUBLIC WORKS December 14, 1978 346 MAIN STREET 726,3753 Mr. Gerald Mills 3656 Game Farm Road Springfield, Oregon 97477 Re: Housing Inspection at 3656 Game Farm Road Dear Mr. Mills: At your request, the Building Division of the 'City of Springfield made a housing inspection on December 12, 1978, at 3656 Game Farm Road, Springfield, Oregon. The, following items must be repaired or replaced to conform "ith the Uniform Hous- ing Code ,as adopted by the City of Springfield: I. All windows must open freely. 2. The vent pipe for the range hood terminates in the attic. This pipe must ex- tend through the roof to the outside atmosphere, and a rain shield cap install- ed on the pipe. 3. The ceiling height on the garage side of the door leading from the kitchen to the garage must be a minimum of 7 feet, and the head room for the stairs at this location must be a minimum of 6 feet 6 inches measured from the nose of the, treads. 4. The quarter bend vent connector (stove pipe) used to connect the wood stove to the chimney must be replaced with an approved type metal chimney fitting "ith an integral clean out section. 5. The concrete chimney used for the wood stove must have an approved fire clay liner installed, and the opening belo" the connection for the wood stove must be sealed "ith concrete. 6. Before using the fireplace in the living room it would be advisable to have the chimney cleaned and' inspected by a licensed chimney s"eep. 7. All 1 ight fixture "iring must be connected in an approved manner in approved junction boxes with the fixture securely fastened to the junction' box. 8. All wire splices in the attic must be taped "ith electrical tape. 9. Install cover plates on all receptacle and switch outlet boxes, replace the broken ones. .)1 , .',~.-. . " '~..l'" ,:,'1::.:' 't'... ' '<ii" ':' . :' 11.' \ Jt'.J.., ti~~ ;.(~:;: ,A.\1' J..., ' Y.t" ..:_1 ;\';':1'" t~.~\.I.. . . . Housing Inspection Page 2. 10. The "lrlng to the pump in the garage must be installed in a meta] race"ay. Splices are not permitted in the field and all splices must be made in an approved junction box. A disconnect must be installed at the pump. All necessary permits sha]] be obtained before work starts and all "ork shall be accomplished according to applicable codes and i~spected before a Certificate of Compliance will be, issued. Please direct all inquiries to the Springfield Building Division at 726-3753. ,-,.,,,, '" ,Sincere , '~r , ~/I ~ L ~"'''~ ~ ,..0 _ ... fY: - .. ~ ,"::, ~( 4~, :;-j!:-c-?"",--, .},: Dan Smith I ~ .. Building Inspector \:; '. :- ,~ , .\ .~... ,~ , '~'\i . .\., , ;l.;I, "f"'. ..r ~~ ~'J. I, f.4 .~ ~t. ~ ..~,', ;. :, !I:'i., I,.,;.. ".-" " . ," '",' DS/lj , "