Loading...
HomeMy WebLinkAboutPermit Building 1997-8-19 (2) I . . / COMMERCIAL/lNDUSTRIAL PERMIT APPLICATION I I ~ .'JOB NUMBE~\'\ \ ?~G:: INSPECTION LINE: 726-3769 OFFICE: 726-37S9 225 Fifth Street, Springfield, Oregon 97477 IIA? ,__ ASSESSORS MAP: ~. .. . , . , LOCATION OF PROPOSED WORK: =? <::; 7 S- c'c:r 1'l1,L /702, /5 4n ;:::c./ WJ il OWNER: ~~/I7 vy/",,;r c;:,.,-!--,,/-J."t'A1<.-,t- ADDRE5:~~~;?f~~()N'^~'M~1 UJhd . / CITY: ' ' STAT'" DESCRIPTION OF WORK: f. J '}1(J i r l.f~/t'tJ,'VJ ~ NEW REMODEL L ADDITION DEMOLISH NAME TAX LOT: .L-/~.::P PHONE: 9'7?,g -r;r/,J/7C/' I)L "{Auf. (/I S", (e, 1-.. (P-1 OTHER ADDRESS ARCHITECT: CONTRACTOR'S NAME ADDRESS GENERAL: ( "'" ~ C..r(..~/ rJ'rh,rt-""f .) I.J () L",!.L/l PLUt,lBINr.. MECHANICA' . ELECTRICAl' PlIIMBING NO. Single Fixture Relocated Bldg. (new fix. addtll Water Service Sanitary Sewer Storm Sewer Backflow DevIce TOTAL PERMIT QUAD AREk o OF BLDG'" OCCY GROUP' o OF STORIES: sa FT. SO. FTG MAIN SO. FTG ACCESR SQ. FTG OTHER t:.-'1 '0;"" PLAN CHECK FEf We . .J I BUILDING PERMIT I 15% State Surchar~.e I MECHANICAL 15% State Surcharae I PAVING CONST. CONTRACTOR' <>u;WJ~ 1'f1J1 ZIP: CJ 7'-f...tl/ / t// C/tv.. ut VALUE. :J ~,-iIS/Jg PHONE EXPIRES PHONE nlJhLj <j9?, 'V;J,'i'~ '\~~)- b't?-nlfJ IECHANICAl I-E!:" I I I I I I I I I I I : I 7v~/l762f ~ " I I b~~/, '/4-A'/ Ie I I I~. ~ ~rt I ?~C'~ U/'7~ :haus! I I j)~;?j:) ~6~~ I I I /~ _ lee I I ,:/,t/C:::' . I I j;f;c..p ~i~:~~~:>~~-; HANDICAP ACCESS' ~~ . FLOOD PLAIN' /7~//?OV~. .ZONINr.:, LIGHTING POWER BUDGET: ,,~ ~G~V?5 7?-~-~:;)~ ~( C:;;$")--~C5> C/ ff: [ ~<::;<,~...,('"""--~ md vent I'~ / ';/,,/ /..-/ I P7-Z~ i~~[ef;OOr i' & vent I f & vent ft. ft. ft. WATER HEATER' ~~ ILUE I I I x TOTAL VALUE OF .PROJECT RCPT: )1ll t) f"1-I6hn&: $10.00 ,.. DATER. \<{-y,CBY\.......~... - I PLUMBING I 5% State Surchan~e I FENCE VAIUF. $ I siDEWALK I CURBCUT . PEMOLlTION FT. FT. I SUBTOTAL PERMITS I SYSTEMS OEVELOPMENT TOTAL PERMIT FEES I EXCLUPING ELECTRICA' >-- . REQUIRED INSPECTIONS . It Is tha responslblllly of the parmi! holder to see that all Inspections ara made at tha proper time. To.requestan Inspection, call 726.3769 (recorder), state your City designated job number, Job address, type of Inspection requested and when you will be ready for Inspection. Requests received before 7:00 8.m. will be made the same working day, requests made after 7:00 a.m. will be made the following work day. SITE INSPECTION: To be made after excavation, but prior to setup of forms. UNDERSLAB PLUMBING. ELECTRICAL & MECHANICAL: To ba made before any work Is covered, ROUGH PLUMBING, ELECTRICAL.& MECHANICAL: No work Is to be covered until these Inspections have been made and approved, PAVING: After gravel Is In place but prior to placing asphalt or concrete. CONCRETE SLAB: To be made after all Inslab building service equipment, conduit, piping, accessories and other ancillary equipment Items are In place but before any concrete Is placed, FIREPLACE: Prior to placing facing materials and bafora framing Inspection. FRAMING: To be made after the roof, all framing, fire blocking and bracing are In place and all pipes, chimneys and vents are complete and the rough electrical, plumbing and mechanIcal are approved, SPECIAL INSPECTIONS: In accordance Section 306 of the State Specialty Code a special Inspector shall be employed by the Ownerl Contractor during construction of the following work. A . copy of tha special testing reports shall be furnished to the Building Division. ATTIC DRAFT STOPS & CURTAIN WALLS FOOTINGS & FOUNDATIONS: To be made after trenches are excavated and forms are erected, all steel In place, but prior to placIng concrete. STRUCTURAL CONCRETE: In excess of 2500 P.S.L (306 a.1) STRUCTURAL WELDS: Performed on the job. (2722 f) UNDERFLOOR: Plumbing, electrical, mechanicaL To be made prior to Installation of floor Insulation, decking or floor sheathIng. INSULATION & VAPOR BARRIER: To be made alter all Insulation and required vapor barriers are In place but bafora any lath or gypsum board Interior wall covering Is applied. FIRE & SEPARATION WALL: Located and constructed according to plans. HIGH STRENGTH BOLTING: During all bolt Installation and tightening operations. (306 a.6) UNDERGROUND: Plumbing, electrical, gas, sanitary sewer, storm sewer, water and drainage lines. To be made prior to covering or filling trenches. SPRAYEO ON FIREPROOFING: u.se. Standards 43-8. SPECIAL GRADING, EXCAVATION AND FILLING: During earthwork. (306 a.11 & Chapter 29) POST & BEAM: To ba mada prIor to Installation of floor Insulation, decking or floor sheathing. LATH AND/OR GYPSUM BOARD: To be made after all lathing and gypsum board, Interior and exterior, Is In place but before any plastarlng Is appllad or before gypsum board Joints and fasteners are taped and finished. GLU.LAM eEAMS: Inspection Certificate by an approved agency, furnished to the City's Building DivIsion befora beams are placed. (2501 U.B.C. STDS. 25-10,11). FLOOR INSULATION & VAPOR BARRIERS: To be made prior to Installation of decking or floor sheathing. STRUCTURAL MASONRY: (306 a.7) MASONRY: Steallocallon, bond beams grouting or verticals In accordance with UBC 2415. SIDEWALK & DRIVEWAY: Required for all concrete paving within street right of way. to be made after all excavating complete and form work and sub-base material In place. ROOF SHEATHING AND NAILING: Prior to Installing any roof coverl "g. CURB AND APPROACH APRONS: Alter forms ara erected but prior to placing concrete. .In addition to the Inspec. tlons specified, the Building Official may make or require other Inspections of any construction work to ensure compllanca with the Building, City or Development Code. ------------------------------------------------------- FINAL ELECTRICAL SITE PLAN REVIEW BOARD: Must ba requested 2 days In advance of the date you wish Inspection. All project condltlons such as landscaping, parkIng lot striping, etc. must be completed before requesting this Inspection. FINAL BUILPING: Requested after the final plumbing, electrical, mechanical and Fire Department Inspections are made and approved. No occupancy of the premises can be made until a Certificate of Occupancy has been Issued by the Building DivisIon and posted on tha premises. FINAL PLUMBING FINAL MECHANICAL FINAL FIRE DEPARTMENT ADDITIONAL COMMENTS: PLANS REVIEWED BY DATF Sy signature, I state and agree, that I have carefUlly examined the completed application and do hereby certify thi't alllnlormatlon herein Is true and correct, and I further certify that any and all work performed shall be done In accordance with the Ordinances of the City of Springfield, and the Laws of the State of Oregon pertaining to the work described herein, and that NO OCCUPANCY will be made of any structure without permission of the Building Safety Division. I further certify that only contractors and employees who are In compliance with ORS 701.055 wltl be usad on this project. I further agree to ensure that all required Inspections are requested at the proper time, that p~oject address Is readable from the street, that the permit card Is located at the front of tha property, and the approved set of plans will remain on the site at all times durlng7/stru':lon. /J Signature . _' _. . S (~ 1./1 A _ Date ~ ~ 19- :? ~ V" '-' VALIDATION: AMOUNT RECEIVFn,. RECEIPT ': DATE PAID: RECEIVED BY'