HomeMy WebLinkAboutNotes, Meeting PLANNER 3/25/2011
.
City of Springfield Development Services Department
225 Fifth Street
Springfield, OR 97477
.
SITE PLAN REVIEW
PRE-SUBMITTAL CHECKLIST
~~
Project Name: Hiatt duplexes
Pre-Submittal Meeting Date: March 25, 2011
Submittal Deadline (180 days): September 21, 2011
Project Proposal: construct 4 duplexes on a vacant parcel
Case Number: PREll-00008
Project Address: none, NW corner of 10th and Q
Assessors Map and Tax Lot Number(s): 17-03-26-13 TLl02
Zoning: MDR (Medium Density Residential)
Overlay District(s): Drinking Water Protection Overlay, 1-5yr Time of Travel zone of the
Q street well.
Applicable Refinement Plan: Q Street Refinement
Refinement Plan Designation: Medium Density Residential
Metro Plan Designation: Medium Density Residential
Associated Applications:
~CI:r:yri OI"4CSPRINGFIELDDEV,ELOPM ENT REVIEW TEAM~~ \H;ll,~::"it:;, ' 9,1;)" ,i,;t1I';bHll~viii~<-il;lI) I
,." . A.. " ' ','M .....".,"'."C , ..".....S.""'A' ."",,,,,,,,,,; . ,..., .1..;.n,.,'
POSITION REVIEW OF NAME PHONE
Project Planner Land Use Planninq Steve Hopkins 726-3649
Transportation Enqineer in Traininq Transportation Michael Liebler 736-1034
Public Works Civil Enqineer Utilities Clayton Mceachern 736-1036
Public Works Civil Engineer Sanitary & Storm Clayton Mceachern 736-1036
Sewer
Deputy Fire Marshal Fire and Life Safety Gilbert Gordon 726-2293
Community Services Manaqer Buildinq Dave Puent 726-3668
"APPLICANTii!S'''[jEV,EI.EO~M ENrrr!'RE~IEW"TEAM.!i2:,,,j;;J:!!!!1!,,!!;,[:;t:t!:::,,f!jf!~!2i!"'!!f!";:'!f;[j!jf!lmml)l!~'t~f ':"", , ','!ffiI!"
Representative: Owner:
Lane Branch Bernard Hiatt
Branch Engineering, Inc 836 R Street
310 5th St Springfield OR 97477
S rin field OR 97477
Revised 4/05/10
Date Received: 3~ ~:5- J/
Planner: "t+
Page 1 of 6
I o:f-trp~
. .
TENTATIVE SITE PLAIN REVIEW APPLICATION
PRE-SUBMITTAL CHECKLIST
PLANNING
o Application Fees (provide a copy of the test fees) $ 4,825.05. This is an estimate. The
fees will be calculated upon application submittal.
More than 10,000sf of impervious surface = base fee ($4,222)+$50/1000 sq ft over 10K
base (up to 10K) sf total
$4 222.00 14418
tech 010
5%
mail"
total
o Copy of the Site Plan reduced to 8'h"x II"
Complete Incomplete See Planning
Note(s)
[gl
o
8 V," x 11" Copy of Site Plan
o Copy of the deed and a preliminary title report issued within the past 30 days
documenting ownership and listing all encumbrances. If the applicant is not the property
owner, written permission from the property owner is required. "
Complete Incomplete See Planning
Note(s)
[gl
tJ
Deed and Preliminary Title Report
o Brief narrative explaining the purpose of the development, the existing use of the
property, and any additional information that may have a bearing in determining the
action to be taken. The narrative should also include the proposed number of employees
and future expansion plans, if known.
Complete Incomplete See Planning
Note(s)
[gl
L1
Brief Narrative
o Site Plan
Complete Incomplete See Planning
Note(s)
l8l
o
l8l
o
1
Prepared by an Oregon Licensed Architect,
Landscape Architect, or Engineer
Proposed buildings: location, dimensions,
size (gross floor area applicable to the
parking requirement for the proposed
use(s)), setbacks from property lines, and
distance between buildings
Location and height of existing or proposed
fences, walls, outdoor equipment, storage,
l8l
o
1
Revised 4/05/10 DRAFT
Page 2 of 6
.
i:8]
G
i:8]
G
0 i:8] 3
i:8] 0
~ L.J
~ 0
i:8]
G
.
trash receptacles, and signs
Location, dimensions, and number of typical,
compact, and disabled parking spaces;
including aisles, wheel bumpers, directional
signs, and striping
Dimensions of the development area, as well
as area and percentage of the site proposed
for buildings, structures, parking and
vehicular areas, sidewalks, patios, and other
impervious surfaces
Observance of solar access requirements as
specified in the applicable zoning district
On-site loading areas and vehicular and
pedestrian circulation
Location, type, and number of bicycle
parking spaces
Area and dimensions of all property to be
conveyed, dedicated, or reserved for
common open spaces, recreational areas,
and other similar public and semi-public uses
Location of existing and proposed transit
facilities
o Phased Development Plan Where applicable, the Site Plan application must include a
phasing plan indicating any proposed phases for development, including the boundaries
and sequencing of each phase. Phasing must progress in a sequence promoting street
connectivity between the various phases of the development and accommodating other
required public improvements, including but not limited to, sanitary sewer, stormwater
management, water, and electricity. The applicant must indicate which phases apply to
the Site Plan application being submitted.
Complete Incomplete See Planning
Note(s)
~
o
o Landscape Plan
Complete Incomplete
See Planning
Note(s)
i:8] 0
[gj 0
o 0
[gj 0
[gj 0
Revised 4/05/10 DRAFT
Phased Development Plan
Drawn by a Landscape Architect
. Location and dimensions of landscaping and
open space areas to include calculation of
landscape coverage
Screening in accordance with SDC 4.4-110
Written description, including specifications, of
the permanent irrigation system
Location and type of street trees
Page 3 of 6
.
.
~
IE~'
""'''':
p
List in chart form the proposed types of
landscape materials (trees, shrubs, ground
cover). Include in the chart genus, species,
common name, quantity, size, spacing and
method of planting
o Architectural Plan
Complete Incomplete See Planning
Note(s)
~
EJ
Exterior elevations of all buildings and
structures proposed for the development site,
including height
Conceptual floor plans
IE'~
.".,,,
,co"'"
~
o On-Site Lighting Plan '
Complete Incomplete See Planning
Note(s)
2
I1llijl
~
~
IE
~
2
Location, orientation, and maximum height of
exterior light fixtures, both free standing and
attached
Type and extent of shielding, including cut-off
angles and type of illumination, wattage, and
luminous area
Photometric test report for each light source
v::1
B
~
2
Planning Notes:
1. If the addresses will be from 10th Street, the rear setback (10') will be from the
western property line. The plan shows only 5'. If the addresses are from Q Street,
the rear setback will be from the northern property line.
2. A photometric test is not required if all lights will be fully shielded and directed
downward. A cut-sheet for a conceptual light fixture is acceptable. Compliance with
this requirement will be verified prior to occupancy of each dwelling.
3. No information on solar access was submitted. Refer to SDC 3.2-225.
. The site is within the 1-5 year time of travel zone of the Q Street well. Submit an
exemption request or a DWP application. Refer to SDC 3.3-200.
Additional comments not related to the completeness of the application:
. Type II site plan review is required for duplexes on property zoned MDR, in
accordance with SDC5.17-105(b).
. Multi-unit design standards do not apply to duplexes. Refer to SDC 3.2-240.
. Parcel size: .58 acre (25,265sf). Max coverage: 45% (1l,369sf). Max coverage
includes roof tops and impervious surface. The pervious paving does not count
toward lot coverage.
Revised 4/05/10 DRAFT
Page 4 of 6
. .
ANY REQUIRED ADDITIONAL MATERIALS, APPLICATIONS OR
PERMITS
IT IS THE APPLICANT'S RESPONSIBILITY TO DETERMINE IF ADDITIONAL STANDARDS OR
APPLICATIONS APPLY TO THE PROPOSED DEVELOPMENT. THE APPLICANT SHOULD
CONSIDER UTILIZING EITHER THE DEVELOPMENT ISSUES MEETING OR THE PRE-
APPLICATION REPORT FOR MORE DETAILED INFORMATION:
Applicable
Not
Applicable
I::ill
I::ill
o
[]
o.
On
.'C
I::ill
F"1
Ld
o
D
I::ill
I::ill
o
I::ill
I::ill
o
D
IdQ
I::ill
o
Revised 4/05/10
Where a multi-family development is proposed, any additional
materials to demonstrate compliance with SDC 3.2-240
Riparian Area Protection Report for properties located within 150
feet of the top of bank of any Water Quality Limited Watercourses
(WQLW) or within 100 feet of the top of bank of any direct
tributaries of WQLW
A Geotechnical Report prepared by an engineer must be submitted
concurrently if there are unstable soils and/or a high water table
present.
Where the development area is within an overlay district, address
the additional standards of the overlay district
If five or more trees are proposed to be removed, a Tree Felling
Permit as specified in SDC 5.19-100
A wetland delineation approved by the Oregon Division of State
Lands must be submitted concurrently where there is a wetland on
the property
Any required federal or state permit must be submitted
concurrently or evidence the permit application has been
submitted for review
Where any grading, filling or excavating is proposed with the
development, a Land and Drainage Alteration permit must be
submitted prior to development
Where applicable, any Discretionary Use or Variance as specified in
SDC 5.9-100 and 5.21-100
An Annexation application, as specified in SDC 5.7-100, where a
development is proposed outside of the city limits but within the
City's urban service area and can be serviced by sanitary sewer
Page 5 of 6
.
.
THIS APPLICATION IS:
o COMPLETE FOR PROCESSING
~COMPLETE AND NEEDS MISSING INFORMATION NOTED ABOVE
City Planner
Date
This is not a decision on your application.
180-DAY DEADLINE
. You have 180 days from the date the application was submitted for Pre-Submittal
Review to provide the City with a full application packet.
. A full application packet includes the application form, processing fee and multiple
copies.
120-DAY CLOCK
· Springfield Development Code Section 5.4-105 and Oregon Revised Statutes 227.178
require the City to take final action on a limited land use decision within 120 days
after the application is deemed complete.
. The 120-day processing period for this application begins when a full application
packet is submitted. A full application packet includes the application form, processing
fee and multiple copies. You may choose to include the missing information, or direct
the City to proceed without it.
. No new information may be submitted after the start of the 120-day period unless it is
accompanied with a request for a time extension. The City may extend the 120-day
period for a reasonable period of time. The City may also require additional fees if the
new information is submitted after the Notification to Surrounding Property Owners is
sent out and a second notification is required, or if the new information substantially
affects the application proposal and additional review is required.
Revised 4{05{10 DRAFT
Page 6 of 6
. .
TENTATIVE SITE PLAN REVIEW APPLICATION
PRE-SUBMITTAL CHECKLIST
Engineer: Kyle Greene Case#:.PREll-00008
PUBLIC WORKS ENGINEERING
o Site Assessment of Existing Conditions
Complete Incomplete See PW
Note(s)
N'l
~
r:-Tl
E3
[gJ
[gJ
r:-Tl
li.d
81_.
?""
,;,I.
@
N/A
o
t.:.::J
o
tuill.f
N/A
[gJ
r:-Tl
Et::d.
[gJ
~
[gJ
81..
~%-;
.,....,
Revised 10/25/07
Prepared by an Oregon licensed Landscape Architect
or Engineer
Vicinity Map
The name, location, and dimensions of all existing site
features including buildings, curb cuts, trees and
impervious surface areas, clearly indicating what is
remaining and what is being removed. For existing
structures to remain, also indicate present use, size,
setbacks from property lines, and distance between
buildings
The name, location, dimensions, direction of flow and
top of bank of all watercourses and required riparian
setback that are shown on the Water Quality Limited
Watercourse Map on file in the Development Services
Department
The 100-year floodplain and floodway boundaries on
the site, as specified in the latest adopted FEMA Flood
Insurance Rate Maps or FEMA approved Letter of Map
Amendment or Letter of Map Revision
The Time of Travel Zones, as specified in SDC 3.3-200
and delineated on the Wellhead Protection Areas Map
on file in the Development Services Department
Physical features including, but not limited to trees 5"
in diameter or greater when measured 4 V2 feet above
the ground, significant clusters of trees and shrubs,
riparian areas, wetlands, and rock outcroppings
Soil types and water table information as mapped and
specified in the Soils Survey of Lane County. A
Geotechnical Report prepared by an Engineer must be
submitted concurrently if the Soils Survey indicates
the proposed development area has unstable soils
and/or a high water table
. .
o Improvement and Public Utilities Plan must be in compliance with the regulations of
SDC Sections 5.17-100, 4.1-100, 4.2-100, and 4.3-100 and must include the following
information:
Complete Incomplete See PW
Note(s)
~
~
o
D
~
o
~
o
o Grading and Paving Plan
Complete Incomplete See PW
Note(s)
~
[]
D
[]
N/A
~
~
~
CJ
o
o
~
LJ
~
o
Prepared by an Oregon licensed Civil Engineer
Location and width of all existing and proposed
easements
Location of existing and required power poles,
transformers, neighborhood mailbox units, and similar
public facilities
Location and size of existing and proposed utilities on
and adjacent to the site, including sanitary sewer
mains, stormwater management systems, water
mains, power, gas, telephone, and cable TV.
Indicate the proposed connection points
Prepared by an Oregon licensed Civil Engineer
Planting plan prepared by an Oregon licensed
Landscape Architect where plants are proposed as
part of the stormwater management system
Roof drainage patterns and discharge locations
Pervious and impervious area drainage patterns
The size and location of stormwater management
systems components, including but not limited to:
drain lines, catch basins, dry wells and/or detention
ponds; stormwater quality measures; and natural
drainageways to be retained
Existing and proposed spot elevations and contours
lines drawn at 1 foot intervals (for land with a slope
over 10 percent, the contour lines may be at 5 foot
intervals)
Amount of proposed cut and fill
o Stormwater Management System Study - provide four (4) copies of the study with
the completed Stormwater Scoping Sheet attached. The plan, calculations, and
documentation must be consistent with the Engineering Design Standards and
Procedures Manual.
Complete Incomplete
See PW
Note(s)
~ [j
Revised 10/25/07
Scoping Sheet and attached Storm water Management
System Study
.
.
PW Notes:
1.
Additional comments not related to the completeness of the application:
o A maintenance agreement will be required for the pervious pavement and the double
chamber catch basin.
o Provide the cut sheets for the pavers and show they can support the 80,000 pound
fire load.
o No roof overhang will be allowed within the vacated right of way.
o What is the 4 inch storm line shown along the west property line?
o A 10 foot public utility easement will be required along the southern property line
and a 7 foot public utility easement will be required along the eastern property
line for future utility use.
Revised 10/25/07
. .
TENTATIVE SITE PLAN REVIEW APPLICATION
PRE-SUBMITTAL CHECKLIST
Deputy Fire Marshal: Gilbert Gordon
Case #: PREll-00008
fIRE
o Site Plan
Complete Incomplete See Fire
Note(s)
1R1
Q
On-site vehicular circulation
o Improvement and Public Utilities Plan
Complete Incomplete See Fire
Note(s)
EJ
Location of existing and required fire hydrants and
similar public facilities
~
Fire Notes:
1.
Additional comments not related to the completeness of the application:
A. Provide specifications to Public Works Engineering verifying the concrete pavers will
support an 80,000 lb. imposed load meeting 2010 Springfield Fire Code 503.2.3 and SFC
Appendix D102.1.
B. Provide "No Parking Fire Lane" signs or markings on both sides of the concrete drive
and paver strips meeting Springfield Fire Code 503.3 and SFC Appendix D103.6 except
at designated parking areas as shown on the plans.
C. Provide curb markings/landscape delineation of the outside edge of the concrete
pavers.
Revised 9{24{07
. .
TENTATIVE SITE PLAN REVIEW APPLICATION
PRE-SUBMITTAL CHECKLIST
Transportation Engineer/Planner: Michael Liebler Case#: PREll-DODOS
Applicant: Hiatt
TRANSPORTATION
o Right-of-Way Approach Permit application must be provided where the property has
frontage on a Lane County or an Oregon Department of Transportation (ODOT) facility.
Complete Incomplete
See Transportation
Note(s)
NA
Copy of ROW Approach Permit Application
[S] 0
o Traffic Impact Study - four (4) copies of a study prepared by a Traffic Engineer in
accordance with SDC 4.2-105 AA. Traffic Impact Studies (TIS) allow the City to analyze
and evaluate the traffic impacts and mitigation of a development on the City's
transportation system. In.general, a TIS must explain how the traffic from a given
development affects the transportation system in terms of safety, traffic operations,
access and mobility, and immediate and adjoining street systems. A TIS must also
address, if needed, City, Metro Plan and state land use and transportation policies and
objectives.
Complete Incomplete
See Transportation
Note(s)
( 1)
Traffic Impact Study
[S] D
o Site Plan
Complete Incomplete
See Transportation
Note(s)
(2)
Access to streets, alleys, and properties to
be served, including the location and
dimensions of existing and proposed curb
cuts and curb cuts proposed to be closed
[S] 0
o Improvement and Public Utilities Plan
Complete Incomplete See Transportation
Note(s)
[S]
o
Location and type of existing and
proposed street lighting
Location, width, and construction material
of all existing and proposed sidewalks,
sidewalk ramps, pedestrian access ways,
and trails
Location, widths (of paving and right-of-
way) and names of all existing and
proposed streets, alleys, dedications,
[gJ D
[S]
o
Revised 10/25/07
.
.
IS!
EJ
access easements or other right-of-ways
within or adjacent to the proposed
development, including ownership and
maintenance status, if applicable
Location of existing and required traffic
control devices
Transportation Notes:
1. A Transportation Impact Study is not required for this development. Traffic
associated with this project will not significantly affect surrounding transportation
facilities operations.
2. Show vision clearance triangles for driveway and intersection on site plan according
to SDC 4.2-130.
Additional comments 'not related to the completeness of the application:
. . Vision clearance requirements shall be met for both the driveway and roadway
intersections per SDC 4.2-130. In addition a clear vision easement for the
intersection corner of 10th St. and Q St. shall be recorded with Lane County after
review by city staff.
Revised 1O/2S/07