Loading...
HomeMy WebLinkAboutMiscellaneous Field Test & Inspection Report 2011-4-8 SfEI TEIlIIlG & INIPEOIOII INC ('...,m.mnical & C'..ombudion Services Compressive Strength of Concrete (ASTM C 39\ CLIENT Mr. Carl Kern Sheltercare . PO Box 23338 Eugene. Oregon 97402 PROJECT AFIYA Apartment Complex 1082 Main SI. Springfield, Oregon DATE PROJECT NO. REPORT NO. 04-08-11 2107080 7474 BPNO. COM 20Q9.01546 DATE CAST 03-11-11 CAST BY D. Delatte DATE RECEIVED 03-14-11 STRENGTH REQUIRED 3000 psi SPECIMEN SIZE 4"xS" STRENGTH PLACED 4000 psi SACKS SUPPLIER ESG PRODUCT CODE 314065 CEMENT MAX SIZE AGG. 3/4" ADDITIVES AEA; Fiber; Hot water AIR CONTENT 4.1% LOAD NO. 1 TICKET NO. 58021915 SLUMP 4" CONCRETE TEMP 72' F YARDAGE 8.0 OF TIME 10:15AM AIR TEMP 50' F WEATHER Overcast SPECIMEN STORAGE 2 day field cure POUR LOCATION Sidewalk on the west side of project. Rem. ASTM C 31 LOAD 1 SAMPLED South end. AVERAGE TEST AGE AREA WEIG~T TOTAL COMPRES~~V~, STRENGTH TIME OF TYPE OF DATE (DAYS) fiN.') (LBS LOAD/LBS' STRENGTH PSI (PSIl TEST FRACTURE" 03-18-11 7 12.56 8.60 42655 3400 8:30 AM 5 04-08-11 28 12.56 6.53 58120 4630 9:20 AM 4 04-08-11 28 12.56 8.56 60000 4780 4705 9:25 AM 3 Hold -1. End Cones 2 - Cone/Split 3 - Columnar 4 - Diagonal 5 - Side (lop Of bottom) 6- Side (pointed lOp or bottom) REMARKS: Chris (Meili Construction) was advised of on-site test results. Reviewed By: fJ1. 'i.17t- Michael L. Meyer . Technical Manager c: Sheltercare - Susan Ban (email) Meili Construction - Curt Meili (email) Meili Construction - Kris Russnogle (email) Meili Construction - Andy Renfro (emaiQ Meili Construction - Chris Hyde (email) Lunabridge - Destin Ferdun (email) Bergsund DeLaney Architecture - Anne DeLaney (email) Bergsund DeLaney Architecture - Julie Romig (email) Hohbach-Lewin - Vikki Bourcier (email) Springfield Church of the Brethren - Dale Seese (email) Michael Roberts - (email) City of Springfield - Denny Wright (email) MLM:sc This report and/or enclosed test data Is the confidential property of the dient to whom it is addressed and pertains to the specific process and/or material evaluated. As such, Information contained herein shall not be reproduced in part or full and/or any part thereof be disclosed without FEI Testing & Inspection. Inc.'s written authorization. 750 NW Cornell Avenue . COIVaIlis, Oregon 9733O . phooe (541) 757-4698 . fax (541) 757-2991 29540 B Airport Road. EUgene, Oregon 97402' phone (541) 684-3849, fax (541) 684-3851 62979 NE Plateau Drive, Suite 3 . Bend, Oregon 97701 . phone (541) 382-4844 . fax (541) 3824846