HomeMy WebLinkAboutMiscellaneous Field Test & Inspection Report 2011-3-31 (~f~J Page 1 of 1 Client: Mr. Carl Kern Sheltercare PO Box 23338 Eugene, Oregon '97402 Project: AFIY A Apartment Complex' 1082 Main Street Springfield, Oregon Date: Project No.: Report No.: BP No.: Asphaltic Concrete 03-31-11 2107080 E-28027 COM 2009-01546 TESTING & INSPECTION, INC C3ec.B:.h oca & CoosIru::Iiln Servres THEORETICAL MAXIMUM SPECIFIC GRAVITY:' AASHTO - T209 Maximum Specific Gravity . Density (pcf} I . 2.477 .154.2 FIELD DENSITY TEST RESULTS ASTM 02950): Compaction Test Approximate Density Percent Requirement No. Test Location (Dcf) . ComDaction I Dercent) 1 Near Main SI. west panel 137.3 89.0 : 91.0 2 Near Main SI. east panel 139.3 90.3 91.0 3 Southwest parking Jot 141.4 91.7 '91.0 4 Drive lane between north and south parking lot west panel 140.6 91.2 91.0 5 Drive lane between north and south parking lot east panel 137.9 89.4 .91.0 6 Northwest parking lot 137.0 89.0 .91.0 7 Drive lane near northwest corner of building 137.9 89.4 91.0 8 Rear fire Janewest end 145.1 94.1 91.0 9 Rear fire lane east end 138.0 89.5 . 91.0 Tests performed at finished grade of wearing course. Bold denotes failing tests. . Remarks: Chris Hyde (Meili Construction) was advised of on-site test results. Notes: percent compaction was calculated using a unit weight of 154.2 Ibs/cu.ft. 'determined from base course sample obtained on 03-30-11. Reviewed By: Mr1~J! f!::r- Technical Manager i c: Sheltercare - Susan Ban (email) Melli Construction - Curt Meili (email) Melli Construction - Kris Russnogle (email) Meili Construction - Andy Renfro (email) Meili Construction - Chris Hyde (email) lunabridge - Destin Ferdun (email) Bergsund Delaney Architecture - Anne Delaney (email) Bergsund Delaney Architecture - Julie Romig (email) Hohbach-lewin - Vikki Bourcier (email) Springfield Church of the Brethren - Dale Seese (email) Michael Roberts - (email) City of Springfield - Denny Wright (email) MlM:sc This report and/or enclosed test dala is the confidential property of tho dient to whom it is addressed ancl pertains to thll specific process and/or material evaluated. As such, infOlTTlalion contained herein shall nO! be reproduced in part or ruu and/or any part thereof be disclosed without FEI Testing & Inspection, Inc.'s wrtlten au thorizatiOl'\ 750 NW Cornell Avenue' Corvallis, Oregon 97330' phone (541) 757-4698. fax (541) 757.2991 29540 B Airport Road. Eugene, Ore90n 97402. phone (541) 684.3849' fax (541) 684-3851 62979 NEPlaleau Olive, 5oite3. Bend, 0mg0n97701. phone (541) 382-4844. fax (541) 3824846