TESTlNG&INSPECfIOfI,INC
GeolechnicaI & Construction Services
Daily Field Report
Client: Mr. Jeff Belnap Project: Hop Valley - Date: 03-28-11
Jeff Belnap Construction, LLC Storage Mezzanine Project No.: 2117036
81300 Dawisson Rd. 980 Kruse Way Report No.: E-28002
Creswell, Oregon 97426 Springfield, Oregon Inspector: D. Delatte
10 No.: 1 080867-88
ICC
Inspection of: Wedge Anchors Weather: Inside Continuous Inspection: 0
Contractor: Jeff Belnap Construction, LLC BPNo.: 800SPR2011-319 Periodic Inspection: 0
Observed the installation of four (4) 1i2" x 5 1/2" Hillman wedge anchors for column
base plate to concrete connection, two (2) anchors per column. Manufacturer's
installation instructions were not available for review. Contractor installed and tightened
anchors to an arbitrary torque value of 40 flIlbs. which was verified with a calibrated
torque wrench. Two (2) anchors, one (1) at each base plate are within :t3/4" of an
expansion joint. One (1) anchor on west side of south column would not tighten to 40
flIlbs. EOR approval is needed for as-built conditions.
To the best of our knowledge, the work inspected was in accordance with plans dated
02-28-11 and applicable workmanship provisions of the I.B.C., except if noted above.
Reviewed By:
~~~~
Vice President
c:
City of Springfield
MLM:sc
R€'Cr-
,/V~
4PR060
lOIT
This report and/or enclosed test data is the confidential property of the client to whom it is addressed and pertains to the
specific process and/or material evaluated. As such, information contained herein shall not be reproduced in part or full
andlor any part thereof be disclosed without FEI Testing & Inspection, Inc. 's written authorization.
750 NW Comell Avenue 'CorvaIlis, Oregon 97330 'phone (541) 757-4698 .fax (541) 757-2991
29540 B Airport Road '&Jgene, Oregon 97402 'phone (541) 684-3849 .fax (541) 684-3851
62979 NE Plateau Drtve, Sutte 3 . Bend, Oregon 97701 . phone (541) 382-4844 . fax (541) 382-4846