Loading...
HomeMy WebLinkAboutMiscellaneous Specifications 2011-3-25 SfEI JESIIIIG & IIJSPECTIOII Ifll ('~ & Conslrul:lioo Ser.iill'!s Compressive Strength of Concrete lASTM C 39) CLIENT Mr. Carl Kern Sheltercare PO Box 23338 Eugene, Oregon 97402 PROJECT AFIYA Apartment Complex 1082 Main SI. Springfield, Oregon DATE PROJECT NO. REPORT NO. 03-25-11 2107080 7443 BPNO. yOM 2009-01546 DATE CAST 02-25-11 CAST BY D. Delatte DATE RECEIVED 02-28-11 STRENGTH REQUIRED : 4000 psi SPECIMEN SIZE 4" x8" STRENGTH PLACED ,4000 psi SACKS SUPPLIER ESG PRODUCT CODE 390528 CEMENT MAX SIZE AGG. 3/8" ADDITIVES Hot water; Fiber AIR CONTENT 2.5% LOAD NO. 1 TICKET NO. 58021738 SLUMP 3 3/4" CONCRETE TEMP 72' F YARDAGE 10.0 OF TIME 8:35 AM AIR TEMP 29' F WEATHER Clear SPECIMEN STORAGE 2 day field cure POUR LOCATION landings and walkways for 2"" and 3" floors. rem. - ASTM C 31 LOAD 1 SAMPLED West end of 3" floor. AVERAGE TEST AGE AREA WEIGHT TOTAL COMPRESSIVE STRENGTH TIME OF TYPE OF OATE IDA YSl tiN.'! 'LBSI LOAD tLBSI STRENGTH ,PSI) 'PSI) TEST FRACTURE~ 03-04-11 7 12.56 8.46 67795 5400 3:50 PM 5 03-25-11 28 12.56 8.48 101700 8100 5:30 PM 2 03-25-11 28 12.56 8.50 102310 8150 8125 5:35 PM 2 Hold ...,. End Cones 2 - ConelSplit: 3- CQlumnar 4- Diagonal 5 - Side (top Of bottom) 6- Side (pointed top or bottom) REMARKS: Chris (Meili Construction) was advised of on-site test results. Reviewed By: /h.-{.~ Michael L. Meyer T echniesl Manager c: Shelteresre - Susan Ban (email) Meili Construction - Curt Meil! (email) Meili Construction - Kris Russnogle (email) Meili Construction - Andy Renfro (email) Meili Construction - Chris Hyde (email) Lunabridge - Destin Ferdun (email) Bergsund DeLaney Architecture - Anne Delaney (email) Bergsund Delaney Architecture - Julie Romig (email) Hohbach-Lewin - Vikki Bourcier (email) Springfield Church of the Brethren - Dale Seese (email) Michael Roberts - (email) City of Springfield - Denny Wright (email) MlM:sc This report andlor enclosed test data is the confidential property of the client to whom It Is addressed and pertains to the specific process andlor material evaluated. As such, information contaIned herein shall not be reproduced in part or full and/or any part thereof be disclosed without FE! Testing & InspectIon, Inc.'s written authorization. 750 t-WV Cornell Avenue. Corvallis, Oregon 97330. phone (541) 757-4698, fax (541) 757-2991 29540 B AiI)lOrl Road . Eugene, Oregon 97402 . phone (541) 664-3849 . fax (541) 684-3851 62979 NE Plateau Drive, Suite 3. Bend, Oregon 97701 . phone (541) 382-4644. fax (541) 382-4646