HomeMy WebLinkAboutBuilding Field Test & Inspection Report 2011-3-14 , " (~FE' Page l' of 1 1EI1II10 & INIPEGlON, INC Geoted1nicaI & Conslrudion SeIVires Report of Inspection Services Welding/High-Strength Bolting Client: Mr. Wally McCullough Project: EWEB 500 E. 4th Ave. Eugene, Oregon 97440 Hayden Bridge Filtration Piant Filter N4, N5 & N6 Improvements Springfield, Oregon Date: Project No.: Report No.: Inspector: IDNo.: Inspection of: Fabricator or Erector: Contractor: Welding F alWest Ironworks Triad Mechanical Shop: Ii1I Weather: BP No.: 03-14-11 2117001 E-27918 R. Bowling 02120381 AWS CWI Field: 0 Inside SPR 2010-00041 Performed continuous visual inspection of complete penetration welds, Prior to inspection, reviewed fabricator's weld procedures, welder qualifications and fit-up. Welding was performed by two (2) certified welders using FCAW process with E71T-1 electrodes. Monitored amps, volts and travel speed for adherence to fabricator's pre-qualified welding procedure. Welding was completed on side 1 of 2-sided complete penetration welds with back gouge on saddle beam seats S5.0-5 (2 pieces) and S5.0-1 (11 pieces). Ultrasonic testing will be performed when components are completed. Chris (FalWest Ironworks) was advised of the shop observations. To the best of our knowledge, the work checked and in-progress is in conformance with revised drawings dated 02-21-11and applicable AWS D1.1 code, except if noted above. Reviewed By: ~:e~.~ Technical Manager c: EWEB - Michael Sticking (email) OBEC- Pete Slocum (email) Triad Mechanical - Dennis Carroll (email) Triad Mechanical - Gary Barnes (email) City of Springfield MLM:sc RECEIVED MAR 2 4 2011 This report and/or enclosed test data is the cOnfidential property of the client to whom it is addressed and pertains to the specific process and/or material evaluated. As such;informatlon contained herein shall not be reproduced in part or full and/or any part thereof be disclosed without FEI Testing 8. Inspection, Inc.'s written authorization. 750 ~CaneII AVfSJ.2' CavalIis, 0reg0097330. J*'t.re(541) 757-4698. fax(541) 757-2991 29540 BAipat Rem . Et.gene, Qeg:xl97402 . ~ (541) 684-3849 . fax (541) B84-3B51 62979NEP\aleaJliMl, SliIe3' Ben:l,Qegcn97701' (trre(541)382-4844 'fax(541)3B2-4846 . ~....... ~r!:l Page 1 of 1 GeolechnicaI & Construction Services Report of Inspection Services Welding/High-Strength Bolting TESTING & INSPEOION, INI Client: Mr. Wally McCullough Project: EWEB 500 E. 4th Ave. Eugene, Oregon 97440 Hayden Bridge Filtration Plant Filler N4, N5 & N6 Improvements Springfield, Oregon Date: ' Project No.: Report No.: Inspector: 10 No.: Inspection of: Fabricator or Erector: Contractor: Welding Farwest Ironworks Triad Mechanical Shop: iii Weather: BP No.: 03-15-11 2117001 E-27919 R Bowling 02120381 AWS CWI Field: 0 Inside SPR 2010-00041 Performed continuous visual inspection of complete penetration welds. Welding was performed by two (2) certified welders using FCAW process with E71T-1 electrodes. Monitored amps, volts and travel speed for adherence to fabricator's pre-qualified welding procedure. '. Complete penetration welding was completed on the following components: walkway ,end supports - 2,1-1, 2.1-3, 2.1-4 and 2.1-5; saddle beam seats - 5.0-1 (8 pieces). Ultrasonic testing was performed on complete penetration welds and is reported under a separate cover. Welding was also completed on walkway frames 3.3-1, 3.4-1,3.5-1 and 3.6-1. Chris (Farwest Ironworks) was advised of the shop observations. To the best of our knowledge, the work checked and in-progress is in conformance with revised drawings dated 02-21-11 and applicable AWS 01.1 code, except if noted above. Reviewed By: fJti:(.~- Michael :. M~ Technical Manager c: EWEB - Michael Sticking (email) OBEC- Pete Slocum (email) Triad Mechanical - Dennis Carroll (email) Triad Mechanical - Gary Barnes (email) City of Springfield MLM:sc This report and/or enclosed test data is the confidential property of the client to whom it is addressed and pertains to the specific process and/or material evaluate(!, As such, information contained herein shall not be reproduced in part or full and/or any part thereof be disclosed Without FEI Testing & Inspection, Inc. 's written authorization. 7fJJNWCaroOA"",,' ~Oregon=' """,(541)757_'12><(541) 757-2991 29540BA>patRoo:l' Eugero, 0reg0n97"". ""'" (541)_' 12><(541) 61143851 62979 NE PIaleaJOriI.e, SLile3' Ben:l, Q'egal97701 '11UJe (541)382-4844' fax(541)382-4848 ~"''''J' ~tt Page 1 of 1 TESTING & IIISPECTION, INC GeoIechnical & Construction SeNices Report of Ultrasonic Examination Client: Mr. Wally McCullough EWEB 500 E. 4th Ave. Eugene, Oregon 97440 Project: Hayden Bridge Filtration Plant Filter N4, N5 & N6 Improvements Springfield, Oregon . Date: Project No.: Rpt. No.: BP No.: Technician: ID#: Shop Ii!! WeldlD: Joint ID: Contractor: Triad Mechanical Fabricator or Erector: Farwest Ironworks 03-15-11 2117001 E-27920 SPR 2010-00041 R. Bowling A.S.NT Level II Field 0 Complete Penetration Plate Corner Splice Decibels DIscontinuity e . e e 0 . 0_ u ~ " .0 D . lf e- If ... B e i ~ fl ~ e 0 e ~~ e ~ Distance Location '" " ';..J e . S ~ 0: ~ l!I~ ,,'" Ii . . .E '" .E E 1l u " g. 0 , If. " 0 ~ j; ." :[~ il " E D ;; e From X FromY .. e 2 D . b d e i!'5 " ~ ... ~ j c j "",- 2lti: Walkway End SUDDOrts 2.1-1 X 70' A 1&2 39 db 2.1-3 X 70' A 1&2 39 db 2.1-4 X 70' A 1&2 39 db 2.1-5 X 70' A 1&2 39 db . Saddle Beam Seats 5.0-1 (8 pieces) X 70' A 1&2 39 db Calibration Blocks: IIW, DSC Frequency. 2.25 mhz Couplet: Sonotech UTY CodeCrtterla: AWSD1.1 Equipment No.: Epoch 48 -Gain dB a-b-c=d Reviewed By: (l~;~ Technical Manager c: EWEB - Michael Sticking (emall) OBEC- Pete Slocum (emall) Triad Mechanical- Dennis Carroll (emall) Triad Mechanical- Gary Barnes (emall) City of Springfield MLM:sc This report and/or enclosed test data is the confidential property of the client to who.m it Is addressed and pertains to the specific process and/or material evaluated. AS such, information contained herein shall not be reproduced in part or full and/or any part thereof be disclosed without FEI Testing & Inspection, Inc.'s written authorization. 79JtWCan9lA\e1.J:!o. Cadl, 08p'l97.m. fhre(541) 7574lJ3 .bc:(,541) 757-2:B1 26llBPlplt"""E1qre,ClBp19741!'I'Jre(541)_.tI<(541)Eil4af>1 62979 NE """"'" 0INe. SuOe3. Ba'd. 0rega197701 . pI"ore (541)382-4844"" (541) 382"",,^ FE) Page 1 of 1 TESTIIIG & IflSPEaIOfl, Ifle Geotechnical & Conslrudion SeM:es Report of Inspection Services Welding/High-Strength Bolting Client: Mr. Wally McCullough Project: EWEB 500 E. 4th Ave. Eugene, Oregon 97440 Hayden Bridge Filtration Plant Filter N4, N5 & N6 Improvements Springfield, Oregon Date: Project No.: Report No.: Inspector: 10 No.: Inspection of: Fabricator or Erector: Contractor: Welding Farwest Ironworks Triad Mechanical Shop: Ii1I Weather:' BP No.: 03-16-11 2117001 E-27921 R. Bowling 02120381 AWS CWI Field: 0 Inside SPR 2010-00041 Performed continuous visual inspection of complete penetration and partial penetration groove welds. Welding was performed by two (2) certified welders using FCAW process with E71T-1 electrodes. Monitored amps, volts and travel speed for adherence to fabricator's pre-qualified welding procedure. Welding was completed on complete penetration joints of beam saddle seats 5.0-1 (3 pieces) and 5.0-5 (2 pieces); walkway end supports 2.1-2 and 1.1-6. Ultrasonic testing was performed on completed sections and on repaired sections, and is reported under a separate cover. Partial penetration welding was completed on column connection clips for columns 2.0-1, 2.0-2, 2.0-3, 2.0-4, 2.0-5 and 2.0-6 Chris (Farwest Ironworks) was advised of the shop observations. To the best of our knowledge, the work checked is in conformance with revised drawings dated 02-21-11 and applicable AWS 01.1 code, except if noted above. Reviewed By: fh.~~ Michaell. Meyer Technical Manager c: EWEB - Michael Sticking (email) OBEe- Pete Slocum (email) Triad Mechanical- Dennis Carroll (email) Triad Mechanical- Gary Barnes (email) City of Springfield MLM:sc This report and/or enclosed test data is the confidential property of the client to Whom it is addressed and pertains to the specmc process andfor material evaluated. As such, Information contained herein shall not be reproduced In part or full and/or any part thereof be disclosed without FEI Testing & Inspection, Inc.'s written authorization. 7f1JWJCardA""'-'" CawII.. o.goo 97330, ptme(541)757-469B 'fax(541) 757-2991 29540 BAipat Roa:l. &qore. o.goo 97402. ptme(541)""""'" 'fax(541)6B4<l851 62979NE PIaIeaJ cnw, SliIe3. Ben::l, ()'egcr197701 . fi'ale(541) 382-4844 .fax(541) 3B2-4846 ~..... ~yttt Page 1 of 1 TESTIlIG & IIISPECTlON, IN( Geotechnical & ConsIrudion Servires Report of Ultrasonic Examination Client: Mr. Wally McCullough EWEB 500 E. 4th Ave. Eugene, Oregon 97440 Project: Hayden Bridge Filtration Plant Filter N4, N5 & N6 Improvements Springfield, Oregon Date: Project No.: Rpt. No.: BPNo.: Technician: 10#: Shop 0 Weld 10: Joint 10: Contractor: Triad Mechanical Fabricator or Erector: Farwest Ironworks 03-16-11 2117001 E-27922 SPR 2010-00041 R. Bowling A.S.NT Level II Field 0 Complete Penetration Plate CornerSplice Decibels DiscontinuIty c . c c 0 . 0_ u " . 0" ~ g- O- e, ~ ~ ~~ ~ II B:$ ~ Distance c c Location 0: ~ .. ~S ';.3 c . - . S . ii ..... "'" . 1l . . .. 0: :;: .. is E " u ,g . 0 0 , . . , 0 " ... j; j; U i . "5 !!1 c E " ~OI!; From X FromY .. E e if a b d c " C . c .!.i: ,. ... .... ... ... ... .. Saddle Beam Seats 5.0-1 #9 X 70' A 1&2 39db 5.0-1 #10 X 70' A 1 39db +2 db 15' 3/8" -0 0 5.0-1 #10 (repair 1) X 70' A 1 39 db -7 db 4" 3/8- -0 +2- 5.0-1 #10 (repair 2) X 70' A 1&2 39 db 5.0-1 #11 X 70' A 1 39 db -5 db 4" , 3/8- -0 +2- 5.0-1 # 11 (repair) X 70' A 1&2 39db 5.0-5 (2 pieces) X 70' A 1&2 39 db Walkwav End Suooorts 2.1-2 X 70' A 1&2 39 db 1.1-6 X 70' A 1 39 db -2 db 4- 3/8- -0 +3- 1.1-6 (repair) X 70' A 1&2 39 db Calibration Blocks: UW,DSC Frequency: 2.25 mhz Cou~let Sonotech UTY CodeCrlterla: AWSD1.1 Equipment No.: Epoch 48 ....Galn dB a-b..c-d Reviewed By: /h.J(.~ Michael L. Meier Technical Manager c: EWEB - Michael Sticking (email) OBEC- Pete Slocum (email) Triad Mechanical- Dennis Carroll (email) Triad Mechanical - Gary Barnes (email) City of Springfield MLM:sc This report andlor enclosed test data is the confidential property of the client to whom it is addressed and pertains to the specific process and/or material evaluated. As such, information contained herein shall not be reproduced in part or full and/or any part thereof 'be disclosed without FEI Testing & Inspection, lnco's written authorization. 7S)NNCmD"""'.""""'0e0:n97m'''''''(541)757'-''''(541)757-2!B1 :!!E4OB/>IpJI_'~0e0:n97<<12'''''''(541)_''''(541)€84Jll51 62979f'.E PI<iaaJ~, Suite 3 . Berd, 0l!gcn97701 . Jfu1e(541) 3B2-4844 .fax(541) 382-4846