HomeMy WebLinkAboutPermit Field Test & Inspection Report 2011-1-24 ~r"'J ~rt Page 1 of 1 TESTING & INSPECTION, INl. GeoIec:hnicaI & Construction Servires Daily Construction Report Client: Ms. Julie Daniel Project: BRING Recycling - Bldg. 10 Date: 01-24-11 BRING Recycling 4446 Franklin Blvd. Project No.: 2117011 4446 Franklin Blvd. Eugene, Oregon Report No.: E-27591 Eugene, Oregon 97403 Inspector: M. Meyer 10 No.: Inspection of: Sitework . Weather: Partly Cloudy/ 550 Continuou~ Inspection: 0 Contractor: Chambers Construction B.P.No. S2010-00566 Periodic Inspection: ~ Met on-site with John Baugus (Chambers Construction) and Mitch O'Brien (Eugene Sand Construction) to observe in-progress footing excavation operations. Presently, excavations have been completed on line B and on line 1, and excavation at lines A2 is near completion. ' Column footing excavation are founded in the medium stiff native silt and sand alluvium strata described in the project soils report dated October 04, 2010. Footing and thickened slab edge excavation depths are sufficient to allow for placement of at least 8" of crushed rock base to raise areas back to proposed bottom of footing/slab edge finished grades. Also, observed placement of 3/4"-0 crushed rock in footing excavation at lines B1. Material is being compacted with a "jumping-jack" and/or vibratory plate compactor. . Mr. O'Brien stated remainder of excavation work will be completed early tomorrow morning and requested field compaction testing be scheduled for mid-day on 01- 25-11. Reviewed By: !h. '-;( i!f-- Michael L. Meyer . Techniqal Manager c: TBG Architects - Ben Rippe (email) Kpff Engineers - Carole Knapel (email) Chambers Construction - Dave Hoffman (email) Hohbach-Lewin, Inc. - Vikki Bourcier (email) City of Springfield MLM:sc , \ This report and/or enclosed test data is the confidential property of the client to whom it is addressed and pertains to the specific process andlor material evaluated, As such, information contained herein shall not be reproduced in part or full and/or any part thereof be disclosed without FEl Testing & Inspection, Inco's written authorization. 750 rm ComeII Averue .Corvallis, Oregon 97330 'pOOre (541) 757-4698 .fax (541) 757-2991 29540 B Airport Road .Eugere, Oregon 97402 'phone (541) 684-3849 .fax (541) 684-3851 R t 62979 NE Plateau Drive, Suite 3 . Bend, Oregon 97701 . phone (541) 382-4844 . fax (541) 3824846 C t I V to FEe 0:1 lO" ~...... . ~ttl Page 1 of 1 TESTING & INSPECTION, INC Geoled1nical & Constnx:lion SeI1Iices Daily Field Report Client: Ms. Julie Daniel Project: BRING Recycling - Bldg. 10 Date: 01-31-11 BRING Recycling 4446 Franklin Blvd. Project No.: 2117011 4446 Franklin Blvd. Eugene, Oregon Report No.: E-27626 Eugene, Oregon 97403 Inspector: M. Meyer 10 No.: 0877905-88 ICC Inspection of: Reinforced Concrete Weather: Cloudy Continuous Inspection: 0 Contractor: Chambers Construction BPNo.: S2010-00566 Periodic Inspection: It:! Performed inspection on the reinforcing steel in column footings at lines 5A.3 and 5A.8. Reinforcing steel was checked for size, grade,quantity, spacing, laps, ties, supports and clearances, where applicable. . Observed the placement of 17.0 yards of Eugene Sand and Gravel 3000 psi concrete (mix 313068) into areas noted above. Concrete was placed directly from trucks and was mechanically consolidated. Cast one (1) set of four (4) 4" x 8" compressive strength cylinders from load 1. Slump - 4 1/4"; concrete temperature - 68F; air temperature - 51 F. John Baugus (Chambers Construction) was advised of the on-site test results and was asked to notify our office when additional services are needed. To the best of our knowledge, the work inspected was in accordance with plans dated 10-20-10, revised detail S2.1-1 dated 11-02-10 and applicable workmanship provisions of the I.B.C., except if noted above. Reviewed By: fJ1. .,(. /k,,____ Michael L. M~a Technical Manager c: TBG Architects - Ben Rippe (email) Kpff Engineers - Carole Knapel (email) Chambers Construction - Dave Hoffman (email) Hohbach-Lewin, Inc. - Vikki Bourcier (email) City of Springfield MLM:sc This report and/or enclosed test data is the confidential property of the client to whom it is addressed and pertains "to the specific process and/or material evaluated. As such, information contained herein shall not be reproduced in part or full and/or any part thereof be disclosed without FEI Testing & Inspection, Inc. 's written authorization. 750 r#J Come/I Aver<Je 'CorvaUis, Oregon 97330 'phone (541) 7574698 .fax (541) 757-2991 29540 BAirportRoad 'Eugene, Oregon 97402 .phone (541) 684-3849'fax (541) 684-3851 62979 NE Plateau Drive, Sune 3 . Bend, Oregon 97701 . phone (541) 382-4844 . fax (541) 382-4846 &FEt Page 1 of 1 TESTinG r. UJ~PEmO~I.lt!C GeQed IIiGaI & Ca1sIndioo 8erIIia!s Daily Field Report Client: Ms. Julie Daniel ProJeCt: BRING Recycling - Bldg. 10 Date: 01-28-11 BRING Recycling 4446 Franklin Blvd. Project No.: 2117011 4446 Franklin Blvd. Eugene, Oregon Report'No.: E-27615 Eugene, Oregon 97403 Inspector: M. Meyer 10 No.: 0877905-88 ICC Inspection of: Reinforced Concrete Weather: Partly Cloudy Continuous Inspection: 0 Contractor: Chambers Construction BPNo.: S2010-o0566 Periodic Inspection: iii Performed inspection on the reinforcing steel in all column footings, except ,at lines 5A.3 and SA.8. Reinforcing steel was checked for size, grade, quantity, spacing, laps, ties, supports and clearances, where applicable. 1 Observed the placement of 47.25 yards of Eugene Sand and Gravel 3000 psi concrete (miX 313068) into areas noted above. Concrete was placed by pump and was" mechanically consolidated. Cast one (1) set of four (4) 4' X 8' compressive strength cylinders from load 2. Slump - 3 112'; concrete temperature - 71 F; air temperature - 53F.' . ~ . - . _ I 'r '.- .' John Baugus.(Chambers,Construction) was advised of the on-site test results and was asked to notify our, office when'additional.services'are needed." ....".. ,,- '" --i';' ..,....,_,.... ,,,,,""",,,. ..""-.~'_".I"-_''":.:.O. ",' .;..:..."~,,.. ,:., \:.:-':.r.",' _.'..~.',..~~:.,.\il.!(}:;}S:;;iJ~~;:-~;~!. :-;:';'..: .tt'\ '-~: '~;'6 ~~~tiisi'~ici~;~~i1vi~ge;ihecwO~.iri~p&iiK{ was'.iri'a;;CC;~a~&r\;;ith :Plan;"dai'Eid'<' 0,0 10-20-10 and applicable workmanship provisions of the I. B.C., except if noted above. Reviewed By: A. 'f.~ Michael L.-Me(er Technical Manager c: TBG Architects - Ben Rippe (email) Kpff Engineers - Carole Knapel(email) Chambers Construction - Dave Hoffman (email) Hohbech-Lewin, Inc. - Vikki Bourcier (emeil) City of Springfield MLM:sc ' :_;~:': ;-::.:.: ':-:: . .r .J:' ~S(:~-)0 3f.'Q S'br.)::C~..:1'3li,'J~:~!,1'.;1~;:::.';~) ~~:-{\'-:)lm;~~ C', ;::s ~'='C" t;~;~:~~ r~ 'JO~0q .:~2t~~;. I r; ~ '0. ~."~_~,, r - (~"":. ." !'"If \ '~,. -,:, ..-' ,''''": ,', ~.,.~ !' "..... '~'r-~" '.,~~'" ,I' -.,............, ,''',-:.. ;..,,,. '. ~""f "'':':''~ ~,I" " This report arid/or enclosed teSt'data is the confidential prOp8rti~of thi.. ciieOt'to'-'whom'~ is addn;ai8(fiind'p~~ins to the specific process and/o~ material evaluated. As such, information contained herein shall not be reproduced In part or full -.:' '~"'_8nd/or any part thereof be disclosed withOut FEI Teating;&-Inapectlon; Inc. 's written authorization, . . . 750 NWComeII A\IllIlJe 'CoNaIIis, Oregon 97330'phone (541) 757-4698 .fax(541) 757-2991 29540 BAirportRoad 'Eugene, Oregon 97402 . phone (541) 6843849 .fax(541) 684-3851 62979 NE PIaleau Drive, Suile3. Bend, Oregon 97701 . phone (541) 3824844, fax (541) 3824846 '~....~ ~rtl Page 1 of 1 TEITING& 1IIIPECTlOlI, INC GeolechnicaI & Construction SeMres Field Density Test Results - ASTM D 2922 Client: Ms. Julie Daniel BRING Recycling 4446 Franklin Blvd. Eugene, Oregon 97403 Project: BRING Recycling - Bldg, 10 4446 Franklin Blvd. Eugene, Oregon Date: Project No.: Report No.: B.P. No.: 01-25-11 2117011 E-27592 S2010-00566 MOISTURE/DENSITY DATA: AASHTO T99 - Maximum Dry Density of 125.0 pcf, at 12.0% moisture furnished by contractor for 3/4" -0 crushed gravel - north pit (Eugene Sand and Gravel). Wet . , , Test Approximate Location Approx. Density Percent Dry Density Percent Compaction No. Elev. IDCfl Moisture 'IDCfl ComDaction Reauirement 1 Near lines 4B - footing FG 133.4 7.5 124.1 99.0 95.0 2 Near lines 38 - footing FG 129.6 8.1 119.9 96.0 95.0 3 Near lines 2B - footing FG 131.6 7.8 122.1 98.0 95.0 4 Near lines 1 B - footing FG 137.8 11.7 123.3 99.0 95.0 5 Near lines 1 A. 7 - footing FG 136.8 9.4 125.0 100.0 95.0 6 Near lines 1A.3 - footing FG 137.3 8.3 126,7 100+ 95.0 7 Near lines 1A - footing FG 140.9 9.9 128.2 100+ 95.0 8 Near lines 2A - footing FG 133,9 7.5 124,5 100.0 95.0 9 Near lines 2A.5 - slab FG 129.1 6.6 121,1 97.0 95.0 10 Near lines 3A.5 - slab FG 133.0 7.4 123.8 99.0 95.0 , Tests performed at finished grade of base rock under footings and slab. Remarks: John (Chambers Construction) was advised of test results. Reviewed by: ;h.:(.~ Michael L.' Mefer Technical Manager c: TBG Architects - Ben Rippe (email) Kpff Engineers - Carole Knapel (email) Chambers Construction - Dave Hoffman (email) Hohbach-Lewin, Inc. - Vikki Bourcier (email) City of Springfield MLM:sc This report and/or enclosed test data is the confidential property of the client to whom it is addressed and pertains to the specific process adlor material evaluated. As such, infonnation contained herein shall not be reproduced in part offul! and/or any part thereof be disclosed without FEr Testing & Inspection, Inc,'s written authorization. 750NW CaneIl A""'IE' Cav.illis, 0rejpt97330' phooe(541) 757-4698 . fux(541) 757-2991 29540 B AirpatRral. ~ Oregoo W4fJ2. phcre(541)684-3849' fux(541)684-3851 62979 NE Plateau Drive, Surre 3. Bend, Oregon 97701 . phone (541) 382-4844. fax (541) 382-4846 TESTIIIG & INSPEGION, [NC r~nrnl & C'..onslrudion SeMa3s Compressive Strength of Concrete (ASTM C 39} '-~ 'j t ~ ,j ! , ~fEI CLIENT Ms. Julie Daniel PROJECT BRING Recycling - Bldg. 10 DATE 02-04-1.1 BRING Recycling 4446 Franklin Blvd. PROJECT NO. 2117011 4446 Franklin Blvd. Eugene, Oregon REPORT NO. 7362 Eugene, Oregon 97403 BPNO. S201 Q.-00566 CAST BY M. Meyer DATE RECEIVED 01-31-11 , DATE CAST 01-28-11 ~ STRENGTH REQUIRED 3000 psi SPECIMEN SIZE 4"xB" , l STRENGTH PLACED 3000 psi SACKS SUPPLIER ESG 1 PRODUCT CODE 313068 CEMENT MAX SIZE AGG. 3/4" ADDITIVES AIR CONTENT 'i LOAD NO. 2 TICKET NO. 58021204 SLUMP. 3 1/2" .1 CONCRETE TEMP 71" F YARDAGE 11.00 OF 47.25 TIME 1:15PM AIR TEMP 53" F WEATHER Partly Cloudy SPECIMEN STORAGE ASTM C 31 POUR LOCATION All column footings except at lines 5A.3 and 5A-8. i .! LOAD 2 SAMPLED Footings at lines A 1 and A2. AVERAGE TEST AGE AREA ~IGS~T TOTAL COMPRESSIVE STRENGTH TIME OF TYPE OF DATE IDAYS' (IN.') LBS LOAD (LBS) STRENGTH IPSI' IPSII : TEST FRACTURE- 02-Q4..11 .7 12.56 8.70 33875 2700 8:20 AM 5 02-25-11 28 02-25-11 28 Hold _ 1- End Cones 2 _ ConelSplit 3 - Columnar 4 - Diagonal 5 - Side (top or bottom) 6 - Side (pointed top or bottom) REMARKS: John Baugus (Chambers Construction) was advised of on-site test results. Reviewed By: Mi~'L:'er Technical Manager c: TBG Architects - Ben Rippe (email) Kpff Engineers - Carole Knapel (email) Chambers Construction - Dave Hoffman (email) Hohbach-Lewin, Inc. - Vikki Bourcier (email) City of Springfield MLM:sc RECEIVED FEB.09 7011 This report and/or enc.losed test data is the co~f1dential propert~ of the cl~ent to whom It is addressed and pertains to the specific process and/or matenal evaluated. As such, Information contamed herem shall not be reproduced in part or full and/or any part thereof be disclosed without FEI Testing & Inspection, Inc,'s written authorization. 750 NW Cornell Avenue. Colvallis, Oregon 97330, phone (541) 757-4698. fax (541) 757-2991 29540 B Airport Road' Eugene, Oregon 97402 . phone (541) 684-3849 . fax (541) 684-3851 62979 NE Plateau Drive, Suite 3 . Bend, Oregon 97701. phone (541) 3824844. fax (541) 382-4846