Builders Statement
InsulSafe@ SP
Fiber Glass Blowing Insulation
2&7tJ- 2J7~
C"'7l1
Homeowner Name I Jobsite Name
CoCo kb -yl.
Company Name
~ "- ...,
Builder (sign)
Company Name
Date
Inspected By (sign if required)
Date
OPEN ATTIC APPLICATION
MINIMUM MAXIMUM NET SQ. FT. MINIMUM WEIGHT- MINIMUM MINIMUM
R-VALUE BAGS PER 1000 sa. FT. PER BAG COVERAGE POUNDS PER SQ. FT. INSTALLED THICKNESS SETTLED THICKNESS
Tooblain a Bags per Conlents of bag Weight per sq. ft. 01 Inslalledinsulation Minimum settled insulation
thermal resistance 1000 sq. ft. shall noleaver inslalledinsulation shall shall not be less than: shall not be less than;
(Rlol, of net area: more than: (sq. ft.) nalbe lesslhan: (Ibs.) (in.) (in.)
60 31.4 31.9 0.972 22.00 22.00
49 25.2 39.7 0.780 18.50 18.50
44 22.4 44.6 0.695 16.75 16.75
=t<f- 38 ld-" 19.1 52.5 0.591 14.50 14.50
30 14.9 67.1 0.462 11.75 11.75
26 12.8 77.9 0.398 10.25 10.25
22 10.8 92.9 0.334 8.75 8.75
19 93 107.4 0.289 7.75 7.75
13 6.2 161.7 0.192 5.25 5,25
11 5.3 190.5 0.163 4.50 4.50
WALLS
/
A-VALUE
THICKNESS
. NET AAEA (Sa. FT.)
BAGS USED
BATTSJROLLS (tI)
CEILINGS
FLOORS
THERMAL PERFORMANCE-ATTIC BLOWING APPLICATION
. In accordance with the chart above, you must install the minimum number of bags per 1,000 sq. h. of net area for each
R-Value listed.
. The maximum net coverage must not exceed that specified for each R-Value.
. The insulation must be installed at or above the specified installed thickness for each R-Value.
. Failure to install the required minimum weight per sq. h. of insulation at or above the initial installed thickness will result in
reduced R-Value.
. This product should not be mixed with other blown insulations or the thermal claims will become invalid.
DANGER: RECESSED LIGHT FIXTURES-TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF
SUCH DEVICES. THIS WARNING DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT
FIXTURES WITH THERMALLY PROTECTED BALLASTS.
<02007 CertainTeed Corporation
A Saint-Gobain Company
30-24-298 Builders Statement 2107
Manufacturer Insulation Fact Sheet
This is CertainTeed Corporation InsulSafe@ SP
Fiber Glass Blowing Insulation
CertainTeed II
CertainTeed Corporation
P.O. Box 860
Valley Forge, PA 19482
COVERAGE CHART-OPEN ATTIC APPLICATION
The following thermal performances are achieved at the thicknesses, weights and coverages specified when insulation
is installed with pneumatic equipment in a horizontal open blow application.
MINIMUM MAXIMUM NET sa. FT. MINIMUM WEIGHT- MINIMUM MINIMUM
R-VALUE BAGS PER 1000 sa. FT. PER BAG COVERAGE POUNDS PER sa. FT. INSTALLED THICKNESS SETTLED THICKNESS
Tooblain a Bags per Contents of bag Weight per sq. ft. of Installed insulation Mlnimumsetlledinsulation
thermal resistance 1000 sQ. ft. shall notCQver inslalledinsutabonshall shall not be lesslhan: shall not be less than:
(R)of: 01 net area: mare than: (sq. ft.) not be lesslhan: (Ibs.) (in.) (in.)
60 31.4 31.9 0.972 22.00 22.00
49 25.2 39.7 0.780 18.50 18.50
44 22.4 44.6 0.695 16.75 16.75
38 19.1 52.5 0.591 14.50 14.50
30 14.9 67.1 0.462 11.75 11.75
26 12.8 77.9 0.398 10.25 10.25
22 10.8 92.9 0.334 8,75 8.75
19 9.3 107.4 0.289 7.75 7.75
13 6.2 161.7 0.192 5.25 5.25
11 5.3 190.5 0.163 4.50 4.50
R-Values are determined in accordance with ASTM C687 and C518. Complies with ASTM C764 as Type 1 pneumatic
Application.
Initial installed thickness testing per ASTM C1374 using Unisul VoluMatic III; 4th gear; 15-inch gate opening; 150 ft. x
4-inch diameter internally corrugated blowing hose.
COVERAGE CHART-ClOSED CAVITY RETROFIT (WAllS, FLOORS, CEILINGS) APPLICATIONS
The following thermal performances are achieved at the thicknesses, weights and coverages specified when insulation
is installed with pneumatic equipment in sidewalls. Based on a design density of 1.6 pcf/25.6 KglmJ
REaUIRED OR MINIMUM MAXIMUM NET sa. FT. MINIMUM WEIGHT- INSTALLED
R-VALUE BAGS PER 1000 sa. FT. PER BAG COVERAGE POUNDS PER SQ. FT. THICKNESS
To obtain a Bags per Contents 01 bag Weight per sq. II. 01 Installed insulation
thermal resistance 1000 sq. II. shall not cover installed insulation shall shall not be less than:
(Alol: 01 net area: more than: (sq. II.) not be less than: (Ibs,) (in.)
29 31.2 32.1 0.967 7.25
22 23.7 42.3 0.733 5.50
16 17.2 58.1 0,533 4.00
15 16,1 62.0 0.500 3.75
14 15.1 66.4 0.467 3.50
READ THIS BEFORE YOU BUY
What you should know about R-Values.
The chart shows the R-Value of this insulation. R means resistance to heat flow. The higher the
R-Value, the greater the insulating power. Compare insulation R-Values before you buy.
There are other factors to consider. The amount of insulation you need depends mainly on the
climate you live in. Also, your fuel savings from insulation will depend upon the climate, the type
and size of your house, the amount of insulation already in your house, and your fuel use patterns
and family size. If you buy too much insulation, it will cost you more than what you'll save on fuel.
To get the marked R-Value, it is essential that this insulation be installed properly.