HomeMy WebLinkAboutMiscellaneous Compliance Report 2010-5-26 CertainTeed II Builders Statement InsulSafe@ SP Fiber Glass Blowing Insulation 2&7tJ- 2J7~ C"'7l1 Homeowner Name I Jobsite Name CoCo kb -yl. Company Name ~ "- ..., Builder (sign) Company Name Date Inspected By (sign if required) Date OPEN ATTIC APPLICATION MINIMUM MAXIMUM NET SQ. FT. MINIMUM WEIGHT- MINIMUM MINIMUM R-VALUE BAGS PER 1000 sa. FT. PER BAG COVERAGE POUNDS PER SQ. FT. INSTALLED THICKNESS SETTLED THICKNESS Tooblain a Bags per Conlents of bag Weight per sq. ft. 01 Inslalledinsulation Minimum settled insulation thermal resistance 1000 sq. ft. shall noleaver inslalledinsulation shall shall not be less than: shall not be less than; (Rlol, of net area: more than: (sq. ft.) nalbe lesslhan: (Ibs.) (in.) (in.) 60 31.4 31.9 0.972 22.00 22.00 49 25.2 39.7 0.780 18.50 18.50 44 22.4 44.6 0.695 16.75 16.75 =t<f- 38 ld-" 19.1 52.5 0.591 14.50 14.50 30 14.9 67.1 0.462 11.75 11.75 26 12.8 77.9 0.398 10.25 10.25 22 10.8 92.9 0.334 8.75 8.75 19 93 107.4 0.289 7.75 7.75 13 6.2 161.7 0.192 5.25 5,25 11 5.3 190.5 0.163 4.50 4.50 WALLS / A-VALUE THICKNESS . NET AAEA (Sa. FT.) BAGS USED BATTSJROLLS (tI) CEILINGS FLOORS THERMAL PERFORMANCE-ATTIC BLOWING APPLICATION . In accordance with the chart above, you must install the minimum number of bags per 1,000 sq. h. of net area for each R-Value listed. . The maximum net coverage must not exceed that specified for each R-Value. . The insulation must be installed at or above the specified installed thickness for each R-Value. . Failure to install the required minimum weight per sq. h. of insulation at or above the initial installed thickness will result in reduced R-Value. . This product should not be mixed with other blown insulations or the thermal claims will become invalid. DANGER: RECESSED LIGHT FIXTURES-TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF SUCH DEVICES. THIS WARNING DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT FIXTURES WITH THERMALLY PROTECTED BALLASTS. <02007 CertainTeed Corporation A Saint-Gobain Company 30-24-298 Builders Statement 2107 Manufacturer Insulation Fact Sheet This is CertainTeed Corporation InsulSafe@ SP Fiber Glass Blowing Insulation CertainTeed II CertainTeed Corporation P.O. Box 860 Valley Forge, PA 19482 COVERAGE CHART-OPEN ATTIC APPLICATION The following thermal performances are achieved at the thicknesses, weights and coverages specified when insulation is installed with pneumatic equipment in a horizontal open blow application. MINIMUM MAXIMUM NET sa. FT. MINIMUM WEIGHT- MINIMUM MINIMUM R-VALUE BAGS PER 1000 sa. FT. PER BAG COVERAGE POUNDS PER sa. FT. INSTALLED THICKNESS SETTLED THICKNESS Tooblain a Bags per Contents of bag Weight per sq. ft. of Installed insulation Mlnimumsetlledinsulation thermal resistance 1000 sQ. ft. shall notCQver inslalledinsutabonshall shall not be lesslhan: shall not be less than: (R)of: 01 net area: mare than: (sq. ft.) not be lesslhan: (Ibs.) (in.) (in.) 60 31.4 31.9 0.972 22.00 22.00 49 25.2 39.7 0.780 18.50 18.50 44 22.4 44.6 0.695 16.75 16.75 38 19.1 52.5 0.591 14.50 14.50 30 14.9 67.1 0.462 11.75 11.75 26 12.8 77.9 0.398 10.25 10.25 22 10.8 92.9 0.334 8,75 8.75 19 9.3 107.4 0.289 7.75 7.75 13 6.2 161.7 0.192 5.25 5.25 11 5.3 190.5 0.163 4.50 4.50 R-Values are determined in accordance with ASTM C687 and C518. Complies with ASTM C764 as Type 1 pneumatic Application. Initial installed thickness testing per ASTM C1374 using Unisul VoluMatic III; 4th gear; 15-inch gate opening; 150 ft. x 4-inch diameter internally corrugated blowing hose. COVERAGE CHART-ClOSED CAVITY RETROFIT (WAllS, FLOORS, CEILINGS) APPLICATIONS The following thermal performances are achieved at the thicknesses, weights and coverages specified when insulation is installed with pneumatic equipment in sidewalls. Based on a design density of 1.6 pcf/25.6 KglmJ REaUIRED OR MINIMUM MAXIMUM NET sa. FT. MINIMUM WEIGHT- INSTALLED R-VALUE BAGS PER 1000 sa. FT. PER BAG COVERAGE POUNDS PER SQ. FT. THICKNESS To obtain a Bags per Contents 01 bag Weight per sq. II. 01 Installed insulation thermal resistance 1000 sq. II. shall not cover installed insulation shall shall not be less than: (Alol: 01 net area: more than: (sq. II.) not be less than: (Ibs,) (in.) 29 31.2 32.1 0.967 7.25 22 23.7 42.3 0.733 5.50 16 17.2 58.1 0,533 4.00 15 16,1 62.0 0.500 3.75 14 15.1 66.4 0.467 3.50 READ THIS BEFORE YOU BUY What you should know about R-Values. The chart shows the R-Value of this insulation. R means resistance to heat flow. The higher the R-Value, the greater the insulating power. Compare insulation R-Values before you buy. There are other factors to consider. The amount of insulation you need depends mainly on the climate you live in. Also, your fuel savings from insulation will depend upon the climate, the type and size of your house, the amount of insulation already in your house, and your fuel use patterns and family size. If you buy too much insulation, it will cost you more than what you'll save on fuel. To get the marked R-Value, it is essential that this insulation be installed properly. (02007 CertainTeed Corporation A Saint-Gobain Company 3Q.24-298 Manufacturer Facllnsulation Sheet 2107