Loading...
HomeMy WebLinkAboutPermit Building 2007-7-26 Status Issued CITY OF SPRINGFIELD Building/Combination Permit PERMIT NO: COM2007-00828 ISSUED: 07/26/2007 APPLIED: 06/07/2007 EXPIRES: 01/26/2008 VALUE: $ 1,975,000.00 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line SITE ADDRESS: 3100 Pierce Pkwy ASSESSOR'S PARCEL NO.: 1702300001000 Springfield TYPE OF WORK: Site Work Only TYPE OF USE: Addition Commercial PROJECT DESCRIPTION: Armed Forces Reserve Center Complex Phase II - Main building fdtn and utilities Owner: STATE OF OREGON MILITARY DEPARTMENT Address: PO BOX 14350 SALEM OR 97309 Phone Number: 503-584-3504 I CONTRACTOR INFORMATION I Contractor Type General Plumbing Contractor WILDISH CONSTRUCTION CO HAMMERQUlST INC License 695 50976 Expiration Date 10/22/2007 06/18/2010 Phone 541-485-1700 541-754-9211 BUILDING INFORMATION I # of Units: Primary Occupancy Group: Secondary Occupancy Group: Primary Construction Type Secondary Construction Type: # of Bedrooms: B # of Stories: Height of Structure: Type of Heat: Water Type: Range Type: Energy Path: Sprinkled Building: Lot Size: Sq Ft 1st Floor: Sq Ft 2nd Floor: Sq Ft Basement: Sq Ft Garage/Carport Sq Ft Other: Occupant Load: lIB n/a I DEVELOPMENT INFORMATION I Frontyard Setback: Side 1 Setback: Side 2 Setback: Rearyard Setback: Solar Setbacks: Overlay Dist: # Street Trees Rqd: Paved Drive Rqd: % of Lot Coverage: REQUIRED PARKING Total: Handicapped: Compact: I PUBLIC IMPROVEMENTS' Street Improvements: Storm,~~{I'Sr Available: Specialln~tJCij{JD : :HIS PERMIT SHALL EXPIRE IF THE WORK Notes;.UTHORIZED UNDERTHIS PERMIT IS NOT I;OMMENCED OR IS ABANDONED FOR ANY 180 DAY PERIOD. Sidewalk Type: ATTENTI~~&as~8&\11res you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001- 0090. You may obtain copies of the rules by calling the center. (Note: the telephone number for the Oregon Utility Notification Center is 1-800-332-2344). Pal!e 1 of 4 Status Issued CITY OF SPRINGFIELD Building/Combination Permit PERMIT NO: COM2007-00828 ISSUED: 07/26/2007 APPLIED: 06/07/2007 EXPIRES: 01126/2008 VALUE: $ 1,975,000.00 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line I Valuation Descriotion I Description Type of Construction $ Per Sq Ft or multiplier $1.00 Square Footage or Bid Amount 1,975,000.00 Value Date Calculated Total Value of Project $1,975,000.00 $1,975,000.00 06/11/2007 Foundation Only Use Bid Amount ~ Fee Description Amount Paid Date Paid Receipt Number Plan Review Comm/Ind/Public $4,328.61 6/7/07 1200700000000000720 Plan Review Fire & Life Safety $2,663.76 6/7/07 1200700000000000720 + 10% Administrative Fee $4.50 6/19/07 1200700000000000788 + 5% Technology Fee $2.25 6/19/07 1200700000000000788 + 8% State Surcharge $3.60 6/19/07 1200700000000000788 Inspections - Investig. Plumb $45.00 6/19/07 1200700000000000788 + 10% Administrative Fee $7.30 6/25/07 1200700000000000821 + 5% Technology Fee $3.65 6/25/07 1200700000000000821 + 8% State Surcharge $5.84 6/25/07 1200700000000000821 Storm Sewer - 1st 50 Feet $45.00 6/25/07 1200700000000000821 Storm Sewer Each Addtll00' $28.00 6/25/07 1200700000000000821 + 10% Administrative Fee $873.44 7/26/07 1200700000000000968 + 5% Technology Fee $436.72 7/26/07 1200700000000000968 + 8% State Surcharge $698.75 7/26/07 1200700000000000968 Addressing Assignment $31.00 7/26/07 1200700000000000968 Backflow Device $14.00 7/26/07 1200700000000000968 Building Permit $6,659.40 7/26/07 1200700000000000968 Fixture $2,016.00 7 i26/07 1200700000000000968 Miscellaneous Plumbing $45.00 7/26/07 1200700000000000968 Total Amount Paid $17,911.82 I Plan Reviews I Fire Department Review 06/13/2007 07/13/2007 OK GRG Plans Review: Lane County Armed Forces Center Phase II main building. Job #COM2007-00828. This set of plans consists of structural submittals, foundation plumbing and foundation mechanical plans. Plans appear to meet code requirements. Initial Review 06/08/2007 06/11/2007 APP LLH Pal!e 2 of 4 Building/Combination Permit PERMIT NO: COM2007-00828 ISSUED: 07/26/2007 APPLIED: 06/07/2007 EXPIRES: 01/26/2008 VALUE: $ 1,975,000.00 Status Issued 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line Plan Review Comments 07/24/2007 10 JMP Planninl! Review 07/24/2007 APP EMM 07/24/2007 Planninl! Review 06/13/2007 WE Public Works Review 06/13/2007 APP JHJ 07/24/2007 Structural Review 07/26/2007 APP JMP 07/26/2007 Structural Review 06/11/2007 07/16/2007 WE JMP SUB Review 06/13/2007 07/16/2007 APP DH CITY OF SPRINGFIELD WI. Received special inspection forms and valuation information from Jim Thomas. To be built per approved Modification of Site Plan Review DRC2007-00026 Waiting for Final Site Plan submittal and Development Agreement Attached SDC Worksheet. No SDC's at this time. (JHJ) Received final internal approvals after receiving plumbing information from Tony Dean. Received with 3 large projects on a cart 6/13/2007. See attached documents for 3 structural comments faxed to Mark Danielson. No energy code issues or inspections on this foundation permit. To Request an inspection call the 24 hour recording at 726-3769. All inspections requested before 7:00 a.m. will be made the same working day, inspections requested after 7:00 a.m. will be made the following work day. Site Inspection: To be made after excavation but prior to setting forms. Erosion/Grading Inspection: Prior to ground disturbance and after erosion measures are installed. Ufer Electrical Ground: Install ground rod at footing and call for inspection in conjunction with footing and/or foundation inspection. Footing: After trenches are excavated. Foundation: After forms are erected but prior to concrete placement. Slab: To be made after all inslab building service equipment, conduit piping and other equipment items are in place but prior to concrete. Bolts InstaIJed in Concrete: To be done by a State Certified Special Inspector. Provide inspection test reports to City Building Inspector. Structural Concrete: In excess of 2500 psi. To be done during construction by a State Certified Inspector. Provide results to City Buiding Inspector Final Building: After all required inspections have been requested and approved and the building is complete. Rough Grading: After gravel is in place but prior to placing concrete. Final Paving: After paving is complete. Underslab Plumbing: Prior to filling the trench and including required testing. Pal!e 3 of 4 Status Iss u ed 225 Fifth Street, Springfield, OR 541-726-3753 Phone 541-726-3676 Fax 541-726-3769 Inspection Line Final Plumbing: When all plumbing work is complete. CITY OF SPRINGFIELD Building/Combination Permit PERMIT NO: COM2007-00828 ISSUED: 07/26/2007 APPLIED: 06/07/2007 EXPIRES: 01126/2008 VALUE: $ 1,975,000.00 By signature, I state and agree, that I have carefully examined the completed application and do hereby certify that all information hereon is true and correct, and I further certify that any and all work performed shall be done in accordance with the Ordinances of the City of Springfield and the Laws of the State of Oregon pertaining to the work described herein, and that NO OCCUPANCY will be made of any structure without permission of the Community Services Division, Building Safety. I further certify that only contractors and employees who are in compliance with ORS 701.005 will be used on this project. I further agree to ensure that all required inspections are requested at the proper time, that each address is readable from the street, that the permit card is located at the front of the property, and the approved set of plans will remain on the site at all times during construction. d owpcontractors Signature Paee 4 of 4 7. ~ 6 - 0 Z Date CITY OF SPRINGFIELD SYSTEMS DEVELOPMENT CHARGE WORKSHEET JOURNAL OR JOB NUMBER C0M2007-00825 No SDC Charges at this time. SDC's will be assessed when NAME OR COMPANY: Oregon Military Department building plan is submitted (building square footage and LOCATION: 3100 Pierce Parkway fixtures) along with the site plan (imperviousarea). MAP & TAX LOT NUMBER: 17 02 30 00 01000 DEVELOPMENT TYPE: Foundation Slab and Underslab Utilities NEW DEVELOPED AREA (SF): EXISTING DEVELOPED AREA (SF): TOTAL IMPERVlOUS SURFACE (SF): 1. STORM DRAINAGE IMPERVIOUS SQ. FT. ITE: ITE: LOT SIZE (SF): x No SDC Charges at this time $ 0.336 PER SF ;2. SANITARY SEWER-CITY (see reverse side) A. REIMBURSEMENT COST: NUMBER OF DFU's B. IMPROVEMENT COST: NUMBER OF DFU's TOTAL STORM DRAINAGE SDC:J No SDC Charges at this time o $ 26.03 PER DFU x x $ 19.79 PER DFU TOTAL LOCAL WASTEWATER SDC:1 $ 3. TRANSPORTATION No SDC Charges at this time BLDG AREA TGSF x TRIP RATE x COST PER ADT x NEW TRIP FACTOR NEW: A. REIMBURSEMENT COST: 0.00 x 0 B. IMPROVEMENT COST: 0.00 x EXISTING: A. REIMBURSEMENT COST: ~OO x 0 B. IMPROVEMENT COST: 0.00 x o x $ 19.81 PER TRIP x o NTF $0.00 I o NTF $0.00 I o $ 87.39 PER TRIP x x x $ 19.81 PER TRIP x $0.00 I o NTF o $ 87.39 PER TRIP x 0 NTF $0.00 I TOTAL TRANSPORTATION REIMBURSEMENT SDC: TOTAL TRANSPORTATION IMPROVEMENT SDC: TOTAL TRANSPORTATION SDC:I $ x 4. SANITARY SEWER - MWMC No SDC Charges at this time NEW: A. REIMBURSEMENT COST: NUMBER OF FEU's 0.00 x #N/A PER FEU $0.00 j B. IMPROVEMENT COST: NUMBER OF FEU's 0.00 x #N/A PER FEU $0.00 , EXISTING: A. REIMBURSEMENT COST: NUMBER OF FEU's 0.00 x #N/A PER FEU $0.00 I B. IMPROVEMENT COST: NUMBER OF FEU's 0.00 x #N/A PER FEU $0.00 I MWMC CREDIT IF APPLICABLE (SEE REVERSE) 5. ADMINISTRA TTVE FEES; BASE CHARGE (SUBTOTAL ABOVE) TOTAL MWMC REIMBURSEMENT FEE: TOTAL MWMC IMPROVEMENT FEE: MWMC ADMINISTRATIVE FEE: TOTAL MWMC SDC:I $ - J SUBTOTAL (ADD ITEMS ~2,3,&~_ I $0.00 I $ x 5% , $0.00 TOTAL SEWER ADMINISTRATION FEE: TOTAL TRANSPORTATION ADMINISTRATION FEE: $ 7/23/2007 TOTAL SDC CHARGES' DATE Jesse Jones Civil Engineer, EIT $0.00 i DRAINAGE FIXTURE UNIT (DFU) CALCULATION TABLE NUMBER OF NEW FIXTURES x UNIT EQUIVALENT = DRAINAGE FIXTURE UNITS (NOTE: FOR REMODELS, CALCULA TE ONLY THE NET ADDITIONAL FIXTURES) Foundation Slab and Underslab Utilities FIXTURE TYPE BATHTUB DRINKING FOUNT AlN FLOOR DRAIN, FLOOR SINK INTERCEPTORS FOR GREASE/OILISOLIDSfETC. INTERCEPTORS FOR SANDI AUTO W ASH/ETC. LAUNDRY TUB CLOTHES W ASHER/MOP SINK CLOTHES WASHER - 3 OR MORE (EA) MOBILE HOME PARK TRAP (1 PER TRAILER) RECEPTOR FOR REFRlGERA TOR/W A TER ST A TIONfETC. RECEPTOR FOR COMMERCIAL SlNK/ DISHWASHER/ETC. SHOWER, SINGLE STALL SHOWER, GANG (NUMBER OF HEADS) SINK: COMMERCIAL, RESIDENTIAL KITCHEN SINK: COMMERCIAL BAR SINK: WASH BASINIDOUBLE LAVATORY SINK: SINGLE LAVATORYIRESIDENTIALBAR URINAL, ST ALUW ALL TOILET, PUBLIC INSTALLATION TOILET, PRIVATE INSTALLATION MISCELLANEOUS: NUMBER OF EDU'S* FIXTURES UNIT NEW OLD EQUIVALENT 3 I 3 3 6 2 3 6 12 1 3 2 2 3 2 2 1 5 6 3 DRAINAGE FIXTURE UNITS o o o o o o o o o o o o o o o o o o o o o TOTAL DRAINAGE FIXTURE UNITS = , 0 *EDU (Equivalent Dwelling Unit) is a discharge equivalent to a single family dwelling (20 DFU) set at 167 gallons per day CREDIT CALCULA TION TABLE: BASED ON ASSESSED VALUE IF IMPROVEMENTS OCCURRED AFTER ANNEXATION DATE IN TABLE, CALCULATE CREDITS SEP ARA TEL Y YEAR ANNEXED 1979 or before 1980 1981 1982 1983 1984 1985 1986 1987 1988 1989 1990 1991 RATE PER $1,000 ASSESSED VALUE $529 $5.19 $5.12 $4.98 $4.80 $4.63 $4.40 $4.07 $3.67 $3.22 $2.73 $2.25 $1.80 CREDIT FOR PARCEL OR LAND ONLY lF APPLICABLE IMPROVEMENT (IF AFTER ANNEXATION DATE) YEAR ANNEXED 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 RATE PER $1,000 ASSESSED VALUE $1.45 $1.25 $1.09 $0.92 $0.72 $0.48 $0.28 $0.09 $0.05 $0.00 $0.00 $0.00 x x CREDIT TOTAL $0.00 $0.00 $0.00 225 Fifth Street Springfield, Oregon 97477 541-726-3759 Phone Job/Journal Number COM2007-00828 COM2007 -00828 COM2007-00828 COM2007-00828 COM2007-00828 COM2007-00828 COM2007-00828 COM2007-00828 Payments: Type of Payment Check cReceintl RECEIPT #: Description Addressing Assignment Building Permit Fixture Backtlow Device Miscellaneous Plumbing + 5% Technology Fee + 8% State Surcharge + 10% Administrative Fee Paid By WILDISH SAND & GRAVEL City of Springfield Official Receipt Development Services Department Public Works Department 1200700000000000968 Date: 07/2612007 Item Total: Check Number Authorization Received By Batch Number Number How Received nJm 800029 In Person Payment Total: Page I of 1 2:19:06PM Amount Due 31.00 6,659.40 2,016.00 14.00 45.00 436.72 698.75 873.44 $10,774.31 Amount Paid $10,774.31 $10,774.31 7/26/2007 City of Springfield Community Services Division 225 Fifth Street Springfield, OR 97477 Telephone: (541) 726-3759 Fax.: (541) 726-3689 COl}11J,)o 7 - a" e La bhjo 7 Building Pennit iI Date AIt.'Ml:d h>n.c.a.&~(;Il'lf, CG~"'i'~1L C~lGi ~ hUV/IM11-'''' 'I ProjectTille {m'~I..IlI] CY1tt;/'f'G-~ .:1Jl 0 .~/U~6- tPt::JlLkWIJ-I Project Address Special Ill5pe(:ti(}n and Testing To applicanls of projects requiring special il1SJlection Of tfStilJ& as pn Section 171M oflhe Oregorl SInU:lUrnl Spo:cialty Code. Please review lbe irlfonnBtiort bel9\l'. Wilen you have finished, acknowledge an understanding t1flhe illformation by signing below, and return this form t(J the City. BEFO RE A "PERMIT CAN BE ISSUED: The owner or owner's repreienlative, on the advice of the n:spOllSible Pr*ct Engineer OT .-\rclUtecl. :sbaJl COLnl'1ele, sigJI. and submit to the City for review arid approval this form completed on both the fronl and back. TIle owner and General COl1tractor, where aj}pliclble. shall also acknowledge the following conditions applicable to Special IllSjlection and/or Testing. l. Contractor is responsible for proper notification for the Inspection or Testing ofitemslisted. 2.. Testing laboratory shall take appropriate samples and transport them to tbeir labar:ll(Jry for propel evalUaliOll or testing. . Copies of all laboratory reports ::100 iNpections are to be sent to the City by the Testing A gtnq. 3. Spccial Tnspeclioo AgalC}' is to submit Illl~S and qualirlCatiol1S of on.site Special Iaspectors to tbc: City for approval 4. Special IIlSpi:clor stm'l prQvide in~rcti~n rerm1':': to th~ buildil'lg offici", of3l1 inspection a<:tivities. i. Contractor i3 respomible to review the City approved plans for additional inspection or tcstillg requiremellts that may be noted BEFO RE A CERTJflCA TE OF OCCUPANCY Wl LL BE lSSUED: TIle Special Inspection Agency sbl1l1submil to the Build iog Officilll a SlIllemtnt tl'm all i~m s requiring inspectioa have been fulfilled and rqJGrled and =e to the best of !he inspector's kllOWledlf:, in confDrmll~ with the approved plans, specilicalioos and applicalJ Ie wOTk.._,...t~p provisions. lltose items nol tested and/or inspected shall be. noted in the statement The report is 10 be submitted to the City prior to II reqllest felr fmaf inspections. GE~ ~~L7~~~O,t{O If-'\.O~ ......-.......-. UJ'Lj)'.!N4'L,~n\.., 6 . me (Printed) ~r Si~..:. / / Gell. Contractor Firm Nam~ (.J'rinted) kPFF cONSuLT/lit el./f/fllVf _ (/~~ FET. JEST1NG:s Engineer or Arcbitcct Firm (Printed) Engine&' or ..\rc.fiitect Signature tCiallnspecli{)n Agem:y Name (printed) Fl=.L h:., J ( 1\Jt; fl ' v. ~ __ \ ~p\l \-\(;Pt)~ U Testing Laboratory Name (Pr!nled) TestiJ1g L~ory Rtf S'ignattlre BUIlding Official Name (Pr~~dr 'CD ~I -~ tV CD " rJ .(!) .(!) :-~ :..... :w tV '--J --J .1..;) '(Jl .w (Jl --J (Jl ("J ..... ~ < ~ '!{l ;0 H Z 'G) ." . H lTl b "U 1> Gl ,lTl CD !J1 SPECIAL INSPECTION Al'ID TESTING SCHEDULE I. Reinfon:ed Cooerele, Gunilc, Grout and Mort~T: I Concrete GUllHe Graul Mortar I I GRADING, E.,XCAVATJON.AND Ji1LL X AcceptDnO: tests t VAt J1:~ PSF Estnblish final grade X Fill placeme/l' inspectionlconlinoous X Soil Density A~grel!ate Test of Mix Oes~ Reinforcioe Tes) Mi.-< Desi.gJl.Wei/rllmaste.r eert." Rcinfolcin1! Placement ContinuOllS 8atcl1 Plan t IIlSllett. Inspect Placing Cast SlII1lt!Jcs Samlll es (PickuJJIOeli ver<:d) ComllrtSsion Test' STRUCTlJRAL STEEL/WELDrNG: Sample ood test llist specific members below} Shop maleriaf ideltlil1cation (mill cat) Weld rospe<:tUm . :x Sbop 'Y Field Ultrasonic insp<<lion , Shop Fiel<l High Slrenglh Bellin2 Shop -X-Field :H25 _N _X .~490 _____~ _X Mel3l dctk welding inspectKJn Reinforcing St~1 welding msp~lil'n ReinforcingSled mill certificate Metal Stlw welding inspectitln Concrete insert welding inspeclion Moment resisting sled liarn~ _F _F .x 'X "'" ^ X' Pret1J.S"~-slrl:S3td C01\l;rcle: Pilei p{Jsl-Tel1s Pre-Tens J( Claddin~ A~~le Tests Reinforcing Tests T mdDD res! Mix Desi.gns"' ReinlOrcinR Pltu:emenl Inscll J>lacemenl Com:rue Batchinz CDlltRle PhK%mcnt In~lalion 1l'lSJlcction Cast Slnnl)lcs _._ Picl<-l]!. ~Ies CornvressiOJl T~sts :x 1- -lL STRUCTh'RAL WOOD; Shear wall nailmg inspection Shear Willi andwrs l....t'...~lioll ofGlu-13m fall_. TIC psi Inspection oftrus!l joist fub_ Sample lIDd lest componCllts Fablicntion welding ofsted accessories SMOKE CONTROL: . Leakage lestj/lg . Control V trificaliDn VlRE'PROOnNG: .Placement :~"'t'....ion .Density tem .Thiclclless tests .Inspcd hatching MASO,'l1\Y Spo:inl mspection $lreS5eS used'. fm r g fulilllinaJ)' aa:eptllnc~ 1esU (JmlSonry units, wall prisms) I Subsequent. tests lmOllar, grout. tield wall prisms) D( Plocemenl illspection ot'units, ;md reinrorcrment Masonry ,1IlOI1lIr. grout, end reinforcing sted cerlifJCates ROOFING: .lnsuliltion installation1R- Vallle~ . Te!t strips/seam! AnnmONAL lNSRUcrJONS~OTHER TES;, & INSl'ECl10NS: Form Completed by: 1\J (CI< r;AAf / E foxy:' fX,J#AJJfl(JA) AIUC!I()R...( /1I15T7JJ/..Ar(o/V WP/:7p Dale..2j 2 J,/or . · PROViDE STRENGTH REQUIRED BY A RCHlTECT OR ENGINEER OR CONTRACT DOCUMENT lOCA 1101'1 OF VALVES c;J -.J ...... IV lSI ...... IV c;J c;J ..... ... W IV ..... ..... IV CT\ W (J1 ..... CT\ o H ::2 o " (fl "U it] ~ H IT! r t1 " I> G) IT! lSl lTI .-. -. . PERFORM THESE INSPECTIONS. SPECIAL ESTABLISHED PER 2007 ITEM INSPECTION PROGRAM (1) OSSC SECTION 109 & CHAPTER 17 ..... 'SOILS 'GRADING, EXCAVATION & FILL FINAL FOUNDATION PREPARATION CONCRETE REINFORCING PLACEMENT REINFORCING WELDING REINFORCING COUPLING ANCHOR BOLTS & INSERTS MATERIAL VERIFICATION PREPARATION OF TEST SPECIMENS CONCRFTE PLACEMENT EPOXY -ANCHOR .PI.ACF.MF:NT EXPANSION ANCHOR P'LACEMENT CURING ERECTION OF PRECAST MEMBERS STRUCTURAL STEEl.. HIGH STRENGTH BOLTING WELDING OF ANCHORS AND STUDS WELDING OF STAIRS(RAJUNG SYSTEMS METAL DECK WELDING EMBEDDED PLATES DETAIL CONFORMANCE SHOP WELDING l2) SINGLE PASS FILLET WELDS < 5/16" FILLET WELDS > 5/16" - PARTIAL/COMPLETE PENETRATION FIELD WELDING SINGLE PAC:;C:; FILLET WELDS ~ 5/16" . .FILLET WELDS> 5/16" - PARTIAL/COMPLETE PENETRATION LIGHT GAUGE METAL FRAMING WELDING PREFABRICATED CC)N~~JcnON STRUCTURAL MASONRY SPRAY APPUED FIREPROOFING CONTlNUOUS (3) X X X X X X X X X X X PERIODIC COMMENTS (3) BY GEOTECHNICAL ENGINEER BY GEOTECHNICAL ENGINEER X X X X REF. NOTE 7 RECORD SLUMP. AIR CONTENT AND TEMPERATURE X X X X X X X X REF. OSSC SECTION 1704.3.3 REF. NOTE 4 X REF. NOTE 5 REF. NOTE 5 REF. NOTE 6 X REF. NOTE 5 REF. NOTE 5 REF. NOTE 6 X X REF. NOTE 8 REF. NOTE 9 d75 ~Io ~tvI /~~ /f<sl I:PJrmr!- Nt;,