HomeMy WebLinkAboutNotes, Work PLANNER 3/1/2011
,;{,
-'1'<" .
..,1 y, <.~ -.'-
...... .....,: ~ \
.
, iCity of Springfield
Development Services Department
225 Fifth Street
Springfield, OR 97477
.
.
SITE PLAN REVIEW
PRE-SUBMITTAL CHECKLIST
Project Name: Glenwood OP, LLC
Project Proposal: To construct a 2-story, 19,900 sq ft medical clinic in Glenwood.
Case Number: PRE11-00006
Project Address: undeveloped land east of the intersection of Glenwood and Franklin Blvd.
Assessors Map and Tax Lot Number(s): 17-03-34-31 TL 900, 17-03-34-34 TL 201
Zoning: Community Commercial (CC)
Overlay District(s): N/A
Applicable Refinement Plan: Glenwood
Refinement Plan Designation: Subarea #7: Commercial-Industrial Mixed-Use
Metro Plan Designation: Community Commercial with a Mixed-use Overlay.
Pre-Submittal Meeting Date: March 1, 2011
Application Submittal Deadline: August 28, 2011
Associated Applications: N/A
t'
-\
POSITION
Pro'ect Planner
Trans ortation Plannin En ineer
Engineer-in- Training
Deputy Fire Marshal
REVIEW OF
Land Use Plannin
Trans ortation
Utilities, Sanitary &
Storm Sewer
Fire and
Safet
Buildin
NAME
Mark Metz er 726-3775
Michael Liebler 736-1034
Kyle Greene 726-5750
Life Gilbert Gordon 726-2293
Communit Services Mana er
Dave Puent726-3668
r:?A~~hIG7,lI\l::t'S'.QEY':I.:.()'PMENfI";RE~'Ew'::te'4li11;;Hi :;"dCii,C:;',. , .... "1
Owner/ Applicant Applicant's Representative
Glenwood OP, LLC, c/o Frank Gibson Scott Stolarczyk
Hutchinson, Cox, Coons, et. al. Robertson Sherwood Architects
777 High Street 132 East Broadway, Suite 540
Eugene, OR 97401 541-686-9160 Eugene, OR, 97401 541-342-8077
(f)
Date Received:
Planner: MM
P5'
"3/1 / If
1-[;
Revised 10/25/07
.
. .
TENTATIVE SITE PLAN REVIEW APPLICATION
PRE-SUBMITTAL CHECKLIST
PLANNING
o Application fee - discuss the applicable fees
o Copy of the Site Plan reduced to 8'h"x 11"
Complete Incomplete See Planning
Note(s)
l2iiI
8 V2" X 11" Copy of Site Plan
o Copy of the deed and a preliminary title report issued within the past 30 days
documenting ownership and listing all encumbrances. If the applicant is not the property
owner, written permission from the property owner is required.
Complete Incomplete See Planning
Note(s)
l2iiI
Deed and Preliminary Title Report
o Brief narrative explaining the purpose of the development, the existing use of the
property, and any additional information that may have a bearing in determining the
action to be taken. The narrative should also include the proposed number of employees
and future expansion plans, if known.
Complete Incomplete
See Planning
Note(s)
l2iiI ~
Brief Narrative
o Site Plan
Complete Incomplete See Planning
Note(s)
~
J'F:'TI.......~..
~
~.
<,
. ..~:.. .
See note #1
Prepared by an Oregon Licensed Architect,
Landscape Architect, or Engineer
Proposed buildings: location, dimensions,
size (gross floor area applicable to the
parking requirement for the proposed
use(s)), setbacks from property lines, and
distance between buildings
Location and height of existing or proposed
fences, walls, outdoor equipment, storage,
trash receptacles, and signs'
Location, dimensions, and number of typical,
compact, and disabled parking spaces;
including aisles, wheel bumpers, directional
signs, and striping
Dimensions of the development area, as well
as area and percentage of the site proposed
for buildings, structures, parking and
~
~~.
j>C,<
"~".
~
J'F:'TI
~
~
J'F:'TI
~
Revised 10/25/07
~
.
.
vehicular areas, sidewalks, patios, and other
impervious surfaces
Observance of solar access requirements as
specified in the applicable zoning district
On-site loading areas and vehicular and
pedestrian circulation
Location, type, and number of bicycle
parking spaces
Area and dimensions of all property to be
conveyed, dedicated, or reserved for
common open spaces, recreational areas,
and other similar public and semi-public uses
Location of existing .and proposed transit
facilities
.
1ZJ
1ZJ
~
tiillffil
~
R7I
I2'i8f
r:<<1;I
~
P71
EJ
~
51
o Phased Development Plan Where applicable, the Site Plan application must include a
phasing plan indicating any proposed phases for development, including the boundaries
and sequencing of each phase. Phasing must progress in a sequence promoting street
connectivity between the various phases of the development and accommodating other
required public improvements, including but not limited to, sanitary sewer, stormwater
management, water, and electricity. The applicant must indicate which phases apply to
the Site Plan application being submitted.
Complete Incomplete See Planning N/A
Note(s)
G
P71
~
Phased Development Plan
o Landscape Plan
Complete Incomplete
!gJ
P71
o
Ift0;I
1.;.J.eJ.
See Planning
Note(s)
~
See note #1
Drawn by a Landscape Architect
Location and dimensions of landscaping and
open space areas to include calculation of
landscape coverage
Screening in accordance with SDC 4.4-110
Written description, including specifications, of
the permanent irrigation system
Location and type of street trees
List in chart form the proposed types of
-landscape materials (trees, shrubs, ground
cover). Include in the chart genus, species,
common name, quantity, size, spacing and
method of planting
~
~
~
~
51
51
51
P71
~
o Architectural Plan
Complete Incomplete See Planning
Note(s)
~
Revised 10/25/07
Ift0;I
t:::J
Exterior elevations of all buildings and
@
.
.
structures proposed for the development site,
including height
Conceptual floor plans
I2S1
S
r:::1Jill
o On-Site Lighting Plan
Complete Incomplete See Planning
Note(s)
I":1l
~
/i;l
Location, orientation, and maximum height of
exterior light fixtures, both free standing and
attached
Type and extent of shielding, including cut-off
angles and type of illumination, wattage, and
luminous area
I2S1
@j0
I2S1
See 'note#2
Photometric test report for each light source
Planning Notes:
1. Please include a table summarizing the percentage of coverage for the site that
includes buildings, structures, parking and vehicular areas, sidewalks, patios, and other
impervious surfaces and a calculation of landscape coverage.
,2. Please provide the required photometric test report for each light source.
Additional comments not related to the completeness of the application:
. Please be aware of the new SDC and application forms.
. SUB and Fire and Life Safety have indicated that the back-flow preventer vault must
be located within 10 feet of the water main that is being accessed.
. The dimensions of the backflow device and its current location do not allow it to be
easily accessed.
Revised 10/25/07
GP
. .
ANY REQUIRED ADDITIONAL MATERIALS, APPLICATIONS OR
PERMITS
IT IS THE APPLICANT'S RESPONSIBILITY TO DETERMINE IF ADDITIONAL STANDARDS OR
APPLICATIONS APPLY TO THE PROPOSED DEVELOPMENT. THE APPLICANT SHOULD
CONSIDER UTILIZING EITHER THE DEVELOPMENT ISSUES MEETING OR THE PRE-
APPLICATION REPORT FOR MORE DETAILED INFORMATION:
Applicable
Not
Applicable
fVI. ..
'122SI
o
o
~
fg[
o
o
o
~
~
~
I"'l
L:tj.
~
~
o
I"'l."
ill!J
~
fg[
I"'l
W
Revised 10/25/07
Where a multi-family development is proposed, any additional
materials to demonstrate compliance with SDC 3.2-240
Riparian Area Protection Report for properties located within 150
feet of the top of bank of any Water Quality Limited Watercourses
(WQLW) or within 100 feet of the to"p of bank of any direct
tributaries of WQLW
A Geotechnical Report prepared by an engineer must be submitted
concurrently if there are unstable soils and/or a high water table
present
Where the development area is within a.n overlay district, address
the additional standards of the overlay district
If five or more trees are proposed to be removed, a Tree Felling
Permit as specified in SDC 5.19-100
A wetland delineation approved by the Oregon Division of State
Lands must be submitted concurrently where there is a wetland on
the property
Any required federal or state permit must be submitted
concurrently or evidence the permit application has been submitted
for review
Where any grading, filling or excavating is proposed with the
development, a Land and Drainage Alteration permit must be
submitted prior to development
Where applicable, any Discretionary Use or Variance as specified in
SDC 5.9-100 and 5.21-100
An Annexation application, as specified in SDC 5.7-100, where a
development is proposed outside of the city limits but within the
City's urban service area and can be serviced by sanitary sewer
@'I
.
.
THIS APPLICATION IS:
D COMPLETE FOR PROCESSING
[gJ INCOMPLETE AND NEEDS MISSING INFORMATION NOTED ABOVE
City Planner
Date
This is not a decision on your application. Springfield Development Code Section 5.4-
105 and Oregon Revised Statutes 227.178 require the City take final action on a limited land
use decision within 120 days after the application is deemed complete. The 120-day
processing period for this application begins when all the missing information is submitted or
when you request that the City proceed without the information. You must indicate by either
signing this form or by submitting a written response to the City within seven days of the
date of this form asserting your intentions regarding the provision of the missing information.
If you indicate herein or in your written response that the missing information will be
submitted, then you have 180 days from the date the application was submitted for Pre-
. Submittal Review to provide the City with the missing information. If you refuse to submit
the missing information, then upon receipt of the full application packet and processing fee,
the City will deem the application complete for purposes of starting the 120-day clock and
begin processing the application. No new information may be submitted after the start of
the 120-day period unless accompanied by a request for an extension of the 120-day
processing time. Upbn receipt of a request for extension, the City may extend the 120-day
period for a reasonable period of time. The City may also require additional fees if the new
information is submitted after the Notification to Surrounding Property Owners is sent out
and a second notification is required or if the new information substantially affects the '
application proposal and additional review is required.
I, the owner/applicant, intend to submit all missing items indicated herein to the
City within the lSO-day timeline.
Owner/Applicant's Signature
Date
Revised 1O{25{07
Q
TENTATIVE\ITE PLAN REVIEJtAPPLICATION
PRE-SUBMITTAL CHECKLIST
Deputy Fire Marshal: Gilbert Gordon
'Case #: PREll-00006
FIRE
o Site Plan
Complete Incomplete See Fire
Note(s)
(g]
r0'l
I!;;J
On-site vehicular circulation
o Improvement and Public Utilities Plan.
Complete Incomplete
See Fire
Note(s)
1.
Location of existing and required fire hydrants and
similar public facilities '
IS::<'!
~
Fire Notes:
1. Fire hydrant location on north side of Franklin Boulevard will not wor~ for fire
operations due to high traffic volumes and unable to support sprinkler FDC
location on the above ground vault.
Additional comments not related to the completeness of the application:
I'
A. Location of the above ground backflow preventer vault will not work since it is
inaccessible to the fire department at the proposed location. Also, it is not within 10 feet
of the public water main connection per SUB Water Department rules (refer to Bart
McKee's comments). The above ground vault with a fire department connection (FDe)
supporting the proposed sprinkler system shall be relocated meeting SUB requirements
and in an area capable of supporting fire apparatus.
B. Provide a fire hydrant for a water supply for supporting the FDC on E. 14th Avenue
placed within 10-30 feet of the FDC meeting 2010 Springfield Fire Code 507 and
Appendix C requirements.
C. Fire apparatus access roads shall support an 80,000 lb. imposed load per 2010
Springfield Fire Code 503.2.3 and SFC Appendix Dl02.1.
D. Provide Knox keyed gate switches at the electric gates per SFC 506.1.
Date Received: '. :7 It II /
Planner: MM
Revised 9/24/07
. .
TENTATIVE SITE PLAN REVIEW APPLICATION
PRE..SUBMITTAL CHECKLIST
~
Engineer: Kyle Greene Case#: PREll-00006
PUBLIC WORKS ENGINEERING
Incomplete
o Site Assessment of Existing Conditions
Complete
See PW
Note(s)
1
r;;;;l
l.liEJ
~
[g1
[g1
lei
EJ
r;;;;l
~
lei
N/A
~
I.=:.J
r;;;;l
~
N/A
[g1
lei
~,
[g1
EJ
Revised 10{25{07
Prepared by an Oregon licensed Landscape Architect
or Engineer
Vicinity Map
The name, location, and dimensions of all existing site
features including buildings, curb cuts, trees and
impervious surface areas, clearly indicating what is
remaining and what is being removed. For existing
structures to remain, also indicate present use, size,
setbacks from property lines, and distance between
buildings
The name, location, dimensions, direction of flow and
top of bank of all watercourses and required riparian
setback that are shown on the Water Quality Limited
Watercourse Map on file in the Development Services
Department
The 100-year floodplain and f1oodway;: boundaries on
the site, as specified in the latest adopted FEMA Flood
Insurance Rate Maps or FEMA approved Letter of Map
Amendment or Letter of Map Revision
The Time of Travel Zones, as specified in SDC 3.3-200
and delineated on the Wellhead Protection Areas Map
on file in the Development Services D'E~partment
Physical features including, but not limited to trees 5"
in diameter or greater when measured 4 '12 feet above
the ground, significant clusters of trees and shrubs,
riparian areas, wetlands, and rock outcroppings
Soil types and water table information as mapped and
specified in the Soils Survey of Lane County. A
Geotechnical Report prepared by an Engineer must be
submitted concurrently if the Soils Survey indicates
the proposed development area has unstable soils
and/or a high water table
(J)
Date Received: ,5.1-1 /
Planner: MM
fd' 1- f
. .
o Improvement and Public Utilities Plan must be in compliance with the regulations of
SDC Sections 5.17-100, 4.1-100, 4.2-100, and 4.3-100 and must include the following
information:
Complete Incomplete
See PW
Note(s)
2
r:=J
W
lZl
lZl
lZl
r:l
W2I
r:l
~
lZl
r:=J
8
o Grading and Paving Plan
Complete
Incomplete See PW
Note(s)
~ 3
lZl 4
~
~
[]
[]
lZl
lZl
~ 5
6
r:=J
E2J.
~
r:l
~
[]~0"
~:"'" ..
'.""
N/A
Prepared by an Oregon licensed Civil Engineer
Location and width of all existing and proposed
easements
Location of existing and required power poles,
transformers, neighborhood mailbox units, and similar
public facilities
Location and size of existing and proR,osed utilities on
and adjacent to the site, including sallitary sewer
mains, stormwater management systems, water
mains, power, gas, telephone, and cable TV.
Indicate the proposed connection points
Prepared by an Oregon licensed Civil Engineer
I,
Planting plan prepared by an Oregon licensed
Landscape Architect where plants are",proposed as
part of the stormwater management system
Roof drainage patterns and discharge: locations
Pervious and impervious area drainage patterns
The size and locatiop of stormwater rT)anagement
systems components, including but not limited to:
drain lines, catch basins, dry wells anCl/or detention
ponds; storm water quality measures;:and natural
drainageways to be retained
Existing and proposed spot elevations,: and contours
lines drawn at 1 foot intervals (for land with a slope
over 10 percent, the contour lines may be at 5 foot
intervals)
Amount of proposed cut and fill
o Stormwater Management System Study - provide four (4) copies of the study with
the completed Storm water Scoping Sheet attached. The plan, calculations, and
documentation must be consistent with the Engineering Design Standards and
Procedures Manual.
Complete
Incomplete
See PW
Note(s)
7
rx::1l
~
Revised 10/25/07
,
Scoping Sheet and attached Stormwater Management
System Study
o
.
.
PW Notes:
1. Per SDC 5.17-120 (B) the Site Assessment of the entire development area shall be
prepared by an Oregon licensed Landscape Architect or Engineer" A stamp is
required by either an Oregon licensed Landscape Architect or Engineer.
2. Per SDC 5.17-120 all site plan applications that contain structures over 4,000 square
feet of gross floor area shall be prepared by an Oregon licensed Architect or
Engineer. A stamp is required by either an Oregon licensed Architect or Engineer
for this plan sheet.
3. Per SDC 5.17-120 (F) a registered professional engineer shall stamp the grading and
paving plan for site plans greater than 5,000 square feet of new paving area.
4. Per SDC 5.17-120(F) where plants are proposed as part of the stormwater
management system, an Oregon licensed Landscape Architect may be required.
A stamp will be required by an Oregon licensed Landcape Architect on the
Landscape Plan.
5. Per SDC 5.17-120 (F)(l) roof drainage patterns and discharge locations need to be
clearly shown on the plans. The plans do not clearly show where water flows on
the roof and how it discharges from the roof.
6. Per SDC 5.17-120 (F)(2) pervious and impervious area drainage patterns need to
clearly be shown on the plans. The traffic directional arrows should not be shown
on the Vertical Control Plan to be confused with the flow arrows. :'
7. The applicant proposes to capture all stormwater up to and including the 25 year
storm, and has shown stormwater calculations for the 10 year storm event. Per
EDSPM 4.03.1 show overflow events for the 25 year storm and how it will not
affect public infrastructure or the building.
Additional comments not related to the completeness of the application:
o Per SDC 4.02-105 (G) an Improvement Agreement will be required for 14th Avenue
as a part of this development. ,
o The stormwater report indicates a 5 minute time of concentration. This is overly
conservative and the City only requires a 10 minute time of conc~ntration to be
used. The storm water report may be adjusted to a 10 minute time of
concentration.
o It is difficult to determine how the impervious area slopes in some areas. It would
be helpful if additional spot elevations were shown on the Vertical Control Plan.
o Protect infiltration basin areas from compaction during constuction or return basin
areas to pre-development condition after construction is complete, to maintain
infiltration rates.
o Trees should not be planted in the middle of a water conveyance ditch.
o Per SDC 5.17-120 (A)(9) an elevation view of the trash enclosures will be required
for site plan approval.
o Prior to site plan approval, the depth of top soil and mulch for the Infiltration Basins
will need to be specified on the Landscape Plan. The quantity, species, and
location of plants to be placed in the Infiltration Basins will need to be shown and
the plant list will need to specify the species for every plant listeq.
o Per EDSPM chapter 3 and the BES manual chapter 3, a maintenance agreement for
the stormwater Infiltration Basins will be required prior to site plan approval.
o Per EDSPM 3.03.4.C all building rooftop mounted equipment shall be' provided with
secondary containment or a weather resistant enclosure to prevent leaks, spills
or any fluids from migrating into the storm drainage system.
Revised 10/25/07
cj)
CITY 0 NGFIELD SYSTEMS DEVELOPMENT CHARG
JOURNAL OR JOB NUMBER ESTIMATE
NAME OR COMPANY: Glenwood Op Medical Office Building
LOCATION:
MAP & TAX LOT NUMBER: 1703343100900 & 1703343400201
DEVELOPMENT TYPE: ESTIMATE
NEW DEVELQPEDAREA (S.F.):'
EXISTING DEVELOPED AREA (S.F.):
TOTAL IMPERVIOUS SURFACE (S.F.): No Public Connection
1. STORM DRAINAGE
NEW IMPERVIOUS SQ. FT.
. REIMBURSEMENT COST:
IMPERVIOUS SQ. FT.
B. IMPROVEMENT COST:
IMPERVIOUS SQ. FT.
RKSHEET
19,900.00
630 ITE:
630 lTE:
LOT SIZE (S.F.):
MWMC:
MWMC:
630
630
7;666
x.
$ 0.231 PER SF
x
$ 0.337 PER SF
$ 0.567
TOTAL STORM DRAINAGE SDC:
Cost er SF=
2. SANITARY SEWER-CITY (see reverse side)
A. REIMBURSEMENT COST:
NUMBER OF DFU's
B. IMPROVEMENT COST:
NUMBER OF DFU's
$
104
131.72 PER DFU
x
104
$ 64.29 PER DFU
$ 196.01
TOTAL LOCAL W ASTEW A TER SDC:
x
$20,384.73
3. TRANSPORTATION
BLDG AREA TGSF x TRIP RATE x COST PER ADT x NEW TRIP FACTOR
NEW:
A. REIMBURSEMENT COST:
19.90 x 31.45
B. IMPROVEMENT COST:
19.90 x 31.4;
EXISTING:
A. REIMBURSEMENT COST:
0.00 x 31.45
B. IMPROVEMENT COST:
0.00 x 31.45
0.95
NTF
$30,879.26 I
x
$ 51.94 PER TRIP
x
NTF
$ 112,542. 75 I
x
$ 189.29 PER TRIP
x
0.95
x
$ ; 1.94 PER TRIP x 0.95 NTF $0.00 I
$ 189.29 PER TRIP x 0.95 NTF $0.00 I
S 241.22 TOTAL TRANSPORTATION REIMBURSEMENT SDC:
TOTAL TRANSPORTATION IMPROVEMENT SDC:
TOTAL TRANSPORTATION SDC: $143,422.01
x
4. SANITARY SEWER- MWMC
NEW:
. REIMBURSEMENT COST:
NUMBER OF FEU's 19.90 x. $87.40 PER FEU $1,739.281
B. IMPROVEMENT COST:
NUMBER OF FEU's 19.90 x $1,143.06 PER FEU $22,746.95 I
C. COMPLIANCE COST
NUMBER OF FEU's 19.90 x $19.40 PER FEU $386.00 I
EXISTING:
A. REIMBURSEMENT COST:
NUMBER OF FEU's 0.00 x $87.40 PER FEU $0.00 I
B. IMPROVEMENT COST:
NUMBER OF FEU's 0.00 x $1,143.06 PER FEU $0.00 I
C: COMPLIANCE COST:
NUMBER OF FEU's 0.00 x $19.40 PER FEU $0.00
MWMC CREDIT IF APPLICABLE (SEE REVERSE)
TOTAL MWMC REIMBURSEMENT FEE:
TOTAL MWMC IMPROVEMENT FEE:
TOTAL MWMC COMPLIANCE FEE:
MWMC ADMINISTRATIVE FEE:
TOTAL MWMC SDC: $ 24,882.23
SUBTOTAL (ADD ITEMS 1,2,3, & 4) $ 188,688.97
5. ADMINISTRATIVE FEES:
BASE CHARGE (SUBTOTAL ABOVE)
$
188,688.97 x 5% $9,434.45
TOTAL SEWER ADMINISTRATION FEE:
TOTAL TRANSPORTATION ADMINISTRATION FEE: $
Kyle Greene
2/28/20 II
DATE
TOTAL SDC CHARGES
$0.00
$1,739.28
$22,746.95
$386.00
$ 10.00
$24,882.23
$1,174.06
8,260.39
$198,123.42
.
.
DRAINAGE FIXTURE UNIT (DFU) CALCULATION TABLE
NUMBER OF NEW FIXTURES x UNIT EQUIVALENT ~ DRAINAGE FIXTURE UNITS
(NOTE: FOR REMODELS, CALCULATE ONLY THE NET ADDITIONAL FIXTURES)
ESTIMATE
FIXTURE TYPE
FIXTURES
NEW OLD
UNIT
EQUIVALENT
DRAINAGE
FIXTURE
UNITS
BATHTUB 3 0
DRINKING FOUNTAIN 2 I 2
FLOOR DRAIN, FLOOR SINK 3 3 9
INTERCEPTORS FOR GREASE/OIUSOLIDSIETC 3 0
INTERCEPTORS FOR SAND/AUTO W ASHlETC. 6 0
LAUNDRY TUB 2 0
CLOTHES W ASHERJMOP SINK 3 0
CLOTHES WASHER - 3 OR MORE (EA) 6 0
MOBILE HOME PARK TRAP (l PER TRAILER) 12 0
RECEPTOR FOR REFRlGERA TOR/WATER ST A TIONIETC I 0
RECEPTOR FOR COMMERCIAL SINK! DISHW ASHERlETC 3 0
SHOWER, SINGLE STALL : 2 0
SHOWER, GANG (NUMBER OF HEADS) 2 0
SINK: COMMERCIAL, RESIDENTIAL KITCHEN 2 3 6
SINK: COMMERCIAL BAR 2 0
SINK: WASH BASINIDOUBLE LA V A TORY 2 0
SINK: SINGLE LA V A TORYIRESIDENTIAL BAR 21 I 21
URINAL, STALUWALL , 5 0
TOILET, PUBLIC INSTALLATION 11 6 66
TOILET, PRIVATE INST ALLA TlON 3 0
MISCELLANEOUS: 0
NUMBER OF EDU'S'
TOTAL DRAINAGE FIXTURE UNITS ~ I
104
I
"'BDU (Equivalent Dwellin~ Unit) is a discharge equivalent to a single family dwelling (20 DFU) set at 167 gallons per day
CREDIT CALCULATION TABLE: BASED ON ASSESSED VALUE
IF IMPROVEMENTS OCCURRED AFTER ANNEXATION DATE IN TABLE, CALCULATE CREDITS SEPARA TEL Y
YEAR RATE PER $1,000 YEAR .. RATE PER $1,000
ANNEXED ASSESSED VALUE ANNEXED ASSESSED VALUE
1979 or before $5.29 1992
1980 $5.19 1993 $1.45
1981 $5.12 1994 $1.25
1982 .. $4.98 1995 . $1.09
1983 $4.80 1996 $0.92
1984 $4.63 1997 '. .. $0.72
1985 .-'. $4.40 1998 $0.48
1986 $4.07 1999 ',,"t $0.28
1987 $3.67 2000 $0.09
1988 $3.22 2001 $0.05
1989 $2.73 2002 $0.00
1990 $2.25 2003 $009
1991 $1.80 2004 $0.00
CREDIT FOR PARCEL OR LAND ONLY IF APPLICABLE
IMPROVEMENT (IF AFTER ANNEXATION DA TEl
x
x
$0.00
$0.00
J
CREDIT TOTAL
$0.00 ==:J
I
,
-,
. .
TENTATIVE SITE PLAN REVIEW APPLICATION
PRE-SUBMITTAL CHECKLIST
Transportation Engineer/Planner: Michael Liebler Case#: PREll-00006
Applicant: Glenwood OP., LLC
TRANSPORTATION
o Right-of-Way Approach Permit application must be provided where the property has
frontage on a Lane County or an Oregon Department of Transportation (GDOT) facility.
Complete Incomplete
See Transportation
Note(s)
(3)
Copy of ROW Approach Permit Application
~ ~
o Traffic Impact Study - four (4) copies of a study prepared by a Traffic Engineer in
accordance with SDC 4.2-105 AA. Traffic Impact Studies (TIS) allow the City to analyze
and evaluate the traffic impacts and mitigation of a development on the City's
transportation system. In general, a TIS must explain how the traffic from a given
development affects the transportation system in terms of safety, traffic: operations,
access and mobility, and immediate and adjoining street systems. A TIS must also
address, if needed, City, Metro Plan and state land use and transportation policies and
objectives.
Complete Incomplete
~
IiJ
E1
See Transportation
Note(s)
(1)
Traffic Impact Study
o Site Plan
Complete Incomplete See Transportation
Note(s)
IiJ
~
Access to streets, alleys, and properties to
be served, including the location and
dimensions of existing and proposed curb
cuts and curb cuts proposed to be closed
~
o Improvement and Public Utilities Plan
Complete Incomplete See Transportation
Note(s)
~
t8l
IiJ
~
~
Revised 10/25/07
(j)
Location and type of existing and
proposed street lighting
Location, width, and construction material
of all existing and proposed sidewalks,
sidewalk ramps, pedestrian access ways,
and trails
Location, widths (of paving and right-of-
way) and names of all existing and
proposed streets, alleys, dedications,
- Date Received: 3.-1-1/
Planner: MM ~ 1-:: -g....
IZSJ
(2)
~
.
.
access easements or other right-of-ways
within or adjacent to the proposed
development, including ownership and
maintenance status, if applicable
Location of existing and required traffic
control devices
'l
jg}
17:'%'1
C1;ill.
Transportation Notes:
1. A Transportation Impact Study is not required for this development. Surrounding
transportation facilities currently operate well below capacity thresholds. Traffic
associated with this project will not significantly affect surrounding transportation
facilities operations.
2. A joint use access agreement connecting the adjoining southwest parcel with the
proposed Franklin Blvd. site access shall be executed for final approv:al. This
agreement shall include an access easement extending from the Franklin blvd. access
location through the site to a yet to be determined location along the west property
line. In .Addition, this agreement would include a city right to terminate such
easement when further development of 14th St. is performed.
3. Jurisdictional transfer from LTD to ODOT of a section of land along the Franklin
Boulevard frontage of this site is currently in process. The City recognizes that this
process has postponed the application for approach at this location. An approved
approach permit shall be provided before final site plan approval.
Additional comments not related to the completeness of the application:
. Subsequent submittals shall include a drawing showing future shared site access
configuration depicting the impacts of future Franklin Boulevard imp~ovements and
associated reductions in parking supply. This future shared access shall require a
joint use access agreement and easement to allow for continued access of associated
parcels.
. The applicant is advised that future reduction of parking due to Franklin Boulevard
improvements and reconfigured site access would likely not reduce the number of
parking spaces below current minimum numbers required for this type of
development.
Revised 10/25/07