HomeMy WebLinkAboutMiscellaneous Field Test & Inspection Report 2011-3-2
1@1 Branch Engineering, Inc.
Branch Engineering, Inc Report # 09-077-03
Head~uaners
310 51 Street
Springfield, OR 97477
(541) 746 0637
www.branchenginccnng.com
Salem/Keizer Office
4310 ChefT)' Avenue, NE
Salem, OR 97303
(503) 779 2577
DAILY REPORT OF STRUCTURAL STEEL AND HIGH STRENGTH BOLT SPECIAL INSPECTION
Project East Side Baptist Church
Address & Jurisdiction
4045 Commercial, Springfield, OR
Inspcctor Rick Hernandez
Permit # 811-SPR201O-409
Date 3-02-11
Inspection Type(s) I Coverage
high strength bolts
o Continuous
llYPeriodic; frequency
once
Inspections made, including locations
Tests performed
Items requiring I) correction, 2) correction of previously listed items, and 3) previously listed uncorrected items
Comments Spoke by telephone with metal building engineer (Ronald Bennett) regarding gaps between plates
at some bolt locations previously inspected. Although during our inspection all bolts appeared to be installed to
snug tight condition based on the full effort of the erector, the engineer stated that the gaps should be shimmed
and provided a dctail for such shimming (drawing SD821, no author, date, or seal). Alternately, the plates must
be drawn together by increased tightening effort. At that point (the snug-tight condition with plates in firm
contact at bolt locations), the additional turn-of-the-nut pre-tensioning shall occur.
To the best of my knowledge, work inspected above was in accordance with the building department approved
plans, specifications, and applicable workm nship provisions of the controlling building code.
Inspector Signat lD/Certificate Number ,a-<t (J:JfJ'134z...
Copies to City of Springfield
Cascade View Construction / Matt Knights
East Side Baptist Church I Len Arney .