Loading...
HomeMy WebLinkAboutMiscellaneous Field Test & Inspection Report 2011-3-9 ~ Branch Engineering, Inc. Branch Engineering, Inc Report # 09-077-04 Head~uarters 31051 Street Springfield, OR 97477 (54]) 746 0637 www.branchengineering.com SalemIKeizer Office 43] 0 Cherry A venue, NE Salem, OR 97303 (503) 779 2577 DAILY REPORT OF STRUCTURAL STEEL AND HIGH STRENGTH BOLT SPECIAL INSPECTION Project East Side Baptist Church Address & Jurisdic]ion 4045 Commercia], Springfield, OR Inspector Rick Hernandez Permit # 8] ] -SPR20 10-409 Date 3-09-]] Inspection Type(s) I Coverage high strength bolts o Continuous ~riodic; frequency once Inspections made, including locations Turn-of-the-nut inspection for pre-tensioned condition at main frame haunch and peak ioints Tests performed Items requiring ]) correction, 2) correction of previously listed items, and 3) previously listed uncorrected items Comments A representative sample (1/3) of all ioints of the main frames was inspected for turn-of-the-nut beyond the match marks. All bolts inspected had been turned 1/3 turn (within tolerance) beyond the match mark. Inspection included one ioint (either one haunch or the peak connection) at each frame. It was also noted that ioints which had previously contained a gap at bolt locations had been drawn together. Erector was asked to notify our office if additional services are required To the best of my knowledge, work inspected above was in accordance with the building department approved plans, specifications, and applicable workmanship provisions of the controlling building code. ~ ~ --=- C--(-------~ Inspector Sigrrafure IDICertificale Number ICe '1 '&7'8<r3'/7- Copies to City of Springfield Cascade View Construction / Matt Knights East Side Baptist Church I Len Arney