Loading...
HomeMy WebLinkAboutMiscellaneous Field Test & Inspection Report 2011-2-3 Carlson Testing, Inc. Bend Office Geotechnical Office Eugene Office Salem Office Tigard Office (541) 330-9155 (503) 601-8250 (541) 345-0289 (503) 589-1252 (503) 684-3460 REPORT OF 4 X 8 CONCRETE CYLINDRICAL TEST SPECIMENS Test Methods: ASTM C 39/C 172/C 1064/C D8/C 31/C 143/C 231/C 1231 Date Molded: 02/03/2011 Permit #: SPR2010-00269 Client: MCDONALDS USA LLC - CLINT CAMERON Date Received: 02/04/2011 Job Number: E1101131. Project:. MCDONALDS SPRINGFIELD - REMODEL Address: '3405 GATEWAY ST - SPRINGFIELD, OR Jurisdiction: SPRINGFIELD Contractor: RICH DUNCAN CONSTRUCTION INC - SCOTT JACKSON Subcontractor: Concrete Supplier:. MINI MIX CONCRETE Truck #: 25 Load #: 1 Cast By: S. DAUGHTRY Test Time: 2:30 PM Ticket#: Air Temp. at Sampling Time: Weather: SUNNY 51 Cylinders were cast for the following locations: WEST CORNER OF SOUTH BAY FOOTING /STEM WALL Total Concrete Placement Location: NORTH WEST,SOUTH WEST,SOUTH BAY SOUTH WEST AND SOUTH EAST CORNERS, FOOTING/STEM WALLS AND SLAS Strength Requirement: MixNumber: 3500 3/4 Admix/Amt: 3000 psi fc @ 28 Days Slump: 3.001! % Air: 1. 9% Concrete Temp: ~ Max Agg: 3/4" Cubic Yards: 2 Register Number: 0001195 Lab Location: EUGENE Set Test @ Test Total Avg. Area Unit Type Of Cap Tested No. Davs Date Load Diameter PSI F ractu re Tvne Bv 7 02/10/2011 34575 3.99 12.50 2770 2 PAD 60 SD 28 03/03/2011 45380 3.99 12.50 3630 2 PAD 60 DEB 28 03/03/2011 45355 3.99 12.50 3630 2 PAD 60 DEB 28 03/03/2011 47695 3.99 12.50 3820 2 PAD 60 DEB Distribute attachments. .Average fc @ 28 days 3690 o Please see reverse side for additional information. .~ Job Number: E1101131. Register Number: 0001195 Project: MCDONALDS SPRINGFIELD - REMODEL Datc Molded: 02/03/2011 < I in. [25 mm] Type I Reasonable well-fonned cones on both ends, less than I in. [25 mmJ of cracking through caps Type 2 Well-Formed cone on one end, vertical cracks running through caps, no well-defined cone on other end Type 3 Columnar vertical cracking through both ends, no well-fonned cones -" " Type 4 Diagonal fracture with no cracking through ends; tap with hammer to distinguish from Type 1 Type 5 Side fractures at top or bottom (occur commonly with unhanded caps) Type 6 Similar to Type 5 but end of cylinder is pointed Asterisked (*) average unit PSI test results did not meet listed a~ceptance criteria. Remarks: MCDONALDS USA LLC - CLINT CAMERON TO: CITY OF SPRINGFIELD BUILDING DEPARTMENT DIBBLE ENGINEERING - ROBB DIBBLE RICH DUNCAN CONSTRUCTION INC - SCOTT JACKSON RICH DUNCAN CONSTRUCTION INC - NATE COOKE Project Manager: B. LEACH Reviewed By: Reviewed On 03/04/20,11 Our repons pertain to the material tested/inspected only. Information contained'herein is not to be reproduced. except in full, without prior authorization from this office. Under all circumstances, the infonnation contained in this report is provided subject to all terms and conditions of CTl's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document.