HomeMy WebLinkAboutMiscellaneous Field Test & Inspection Report 2011-2-8 , ~fEI Page 1 of 1 TESTIIlG & INSPECTlON,IIlC GeolechnicaI & Construdion Servires Daily Field Report Client: Ms. Julie Daniel Project: BRING Recycling - Bldg. 10 Date: 02-08-11 BRING Recycling 4446 Franklin Blvd. Project No.: 2117011 4446 Franklin Blvd. Eugene, Oregon Report No.: E-27690 Eugene, Oregon 97403 Inspector: D. Delatte 10 No.: 1080867-88 ICC Inspection of: Reinforced Concrete Weather: Overcast Continuous Inspection: 0 Contractor: Chambers Construction BPNo.: S2010-00566 Periodic Inspection: iii Performed final reinforcing steel inspection for slab on grade with thickened areas on line A to B, from 1 to 5. Preliminary reinforcing steel inspection was peiiormed on 02- 04-11 (ref: FEI report E-27672). I Observed the placement of 80.0 of fl00.0 yards of Eugene Sand and Gravel 3000 psi concrete (mix 313065) into area noted above. Concrete was placed by pump and was mechanically consolidated. Cast two (2) sets of four (4) 4" x 8" concrete test cylinders. I Set 1 - Load 2 Set 2 - Load 7 Slump - 31/4" Slump - 4 1/2" I Concrete temperature - 72F Concrete temperature - "Z2F Air temoerature - 40F Air temoerature - 43F I Air content - 3.1 % Air content - 3.7% I John Baugus (Chambers Construction) was advised of the on-site test results. To the best of our knowledge, the work Inspected was In accordance with revised plans dated 11-02-10 and applicable workmanship provisions of the I.B.c.!, except if noted above. Reviewed By: ;1,,--;(.14- Michael L. Me..;J; Technical Manager c: TBG Architects - Ben Rippe (emaH) Kpff Engineers - Carole Knapel (email) Chambers Construction - Dave Hoffman (emall) Hohbach-Lewin, Inc. - Vikki Bourcier (email) City of Springfield MLM:sc , This report and/or enclosed test data is the confidential property of the client to whom it is addressed and pertains to the specific process and/or material evaluated. As such, information contained herein shall not be reproduced in part or full and/or any part thereof be disclosed without FEI Testing & Inspection, Inc.'s written authorization. i I 750 NW Cornell Avenue 'CorvaOis, Oregon 97330 'phone (541) 7574698 .tax (541) 757-2991 29540 BAirportRoad 'Eugene, Oregon 97402 'phone (541) 684-3849 .fax (541) 684-3851 , 62979 NE Plateau Drive, Suite 3, Bend, Oregon 97701. phone (541) 382-4844. tax (541) 382-4846 Compressive Strength of Concrete . I fASTM C 39) I DATE I PROJECT NO. I REPORT NO. POUR LOCATION Slab on grade with thickened areas line A to B, from 1 to 5. LOAD 2 SAMPLED Near 4.9A.5. AVERAGEI TEST AGE AREA ~IGHT TOTAL COMPRESSIVE STRENGTH TIME OF TYPE OF DATE /DAYSl tlN.'l LBSl LOAD iLBS\ STRENGTH '/PSI\ (PSIl I TEST FRACTURE- 02-15-11 7 12.56 8.65 49570 3950 I 10:30 AM 5 03-08-11 28 I 03-08-11 28 Hold I , ~fEI TESTltIG & INIPEGIOfI, INC Geotechnical & Constn.dion ~ CLIENT PROJECT BRING Recycling - Bldg. 10 4446 Franklin Blvd. Eugene, Oregon Ms. Julie Daniel BRING Recycling 4446 Franklin Blvd. Eugene, Oregon 97403 BPNO. S2010-00566 DATE CAST STRENGTH REQUIRED STRENGTH PLACED PRODUCT CODE ADDITIVES LOAD NO. CONCRETE TEMP AIR TEMP 02-08-11 3000 psi 3000 psi 313065 Hot water; AEA 2 72. F 40. F CAST BY D. Delatte DATE RECEIVED SPECIMEN SIZE , SUPPLIER ., MAX SIZE AGG. , AIR CONTENT I SLUMP TIME I SPECIMEN STORAGE SACKS CEMENT 58021446 10.25 OF Overcast TICKET NO. YARDAGE WEATHER f110.0 -1- End Cones 2 - Cone/Split 3 - Columnar 4 - Diagonal 5 - Side (top or bottom) I 6- Side (pointed lop or bottom) REMARKS: John Baugus (Chambers Construction) was advised of on-site test results. Reviewed By: A. 1(. ~-------- Michael L. Med Technical Manager c: TBG Architects - Ben Rippe (email) Kpff Engineers - Carole Knapel (email) Chambers Construction - Dave Hoffman (email) Hohbach-Lewin, Inc. - Vikki Bourcier (email) City of Springfield MLM:sc This report and/or enclosed test data is the confidential property of the client to whom it is addressed and pertains to the specific process and/or material evaluated. As such, information contained herein shall not be reproduced in part or full and/or any part thereof be disclosed without FEI Testing & Inspection, Inc,'s written authorization. I . I 750 t-NV Cornell Avenue' Corvallis, Oregon 97330, phone (541) 757-4698. fax (541) 757-2991 29540 B Airport Road, Eugene, Oregon 97402 . phone (541) 684-3849 . fax (541) 684-3851 62979 NE Plateau Drive, Suite 3 . Bend, Oregon 97701. phone (541) 382-4844. t.lx (541) 382-4846 I 02-15-11 2117011 7391 02-09-11 4"x8" ESG 3/4" 3.1% 3 1/4" 7:45 AM ASTM C 31 Compressive Strength of Concrete I (ASTM C 39) I DATE I PROJECT NO. I REPORT NO. POUR LOCATION Slab on grade with thickened areas line A to B, from 1to 5. LOAD 7 SAMPLED Near 3A.5. I AVERAGE TEST AGE ~R~ WEIGHT TOTAL COMPRESSIVE STRENGTH TIME OF TYPE OF DATE (DAYS) IN.' lLBSl LOAD (LBSl STRENGTHIPSIl lPSI) I TEST FRACTURE- 02-15-11 7 12.56 8.52 35560 2830 I 10:25AM 5 03-08-11 28 I 03-08-11 28 Hold I , ~..... ~rt. C',eo!echnica! & C'.ansIrucIion Services TESlIIlG & INSPEalON.111C CLIENT Ms. Julie Daniel BRING Recycling 4446 Franklin Blvd. Eugene, Oregon 97403 PROJECT BRING Recyclin9 - Bldg. 10 4446 Franklin Blvd. Eugene, Oregon BPNO. S2010-00566 DATE CAST STRENGTH REQUIRED STRENGTH PLACED PRODUCT CODE ADDITIVES LOAD NO. CONCRETE TEMP AIR TEMP 02-08-11 3000 psi 3000 psi 313065 Hot water; AEA 7 72" F 43' F CAST BY D. Delatte DATE RECEIVED I SPECIMEN SIZE I SUPPLIER I MAX SIZE AGG. I AIR CONTENT I SLUMP TIMEI . SPECIMEN STORAGE SACKS CEMENT 58021462 10.25 OF Overcast TICKET NO. YARDAGE WEATHER t110.0 -1- End Cones 2 _ Cone/Split 3 - Columl1ar 4 - Diagonal 5 - Side (top or bottom) 6 - Side (POiJted top or bottom) REMARKS: John Baugus (Chambers Construction) was advised of on-site test results. Reviewed By: fJJ.t ~- Michael L ~eyll- Technical Manager c: TBG Architects - Ben Rippe (email) Kpff Engineers - Carole Knapel (email) Chambers Construction - Dave Hoffman (email) HOhbach-Lewin, Inc. - Vikki Bourcier (email) City of Springfield MLM:sc 02-15-11 2117011 7392 02-09-11 4"x8" ESG 3/4" 3.7% 4 3/4" 9:10AM ASTM C 31 This report and/or enclosed test data is the confidential property of the client to whom it is addresse;d and pertains to the specific process and/or material evaluated. As such, information contained herein shall not be reproduced in part or full and/or any part thereof be disclosed without FEI Testing & Inspection, Inc,'s written authorization. I 750 tfW Cornell Avenue. Ccrvallis, Oregon 97330, phone (541) 757-4698, tJ (541) 757-2991 29540 B Airport Road. Eugene, Oregon 97402 . phone (541) 684-3849 . fax (541) 684-3851 62979 NE Plateau Drive, Sulle 3 . Bend, Oregon 97101 . phone (541) 382-4644 . fax (541) 382-4846 . I