DAILY REPORT OF STRUCTURAL STEEL AND HIGH STRENGTH BOLT SPECIAL INSPECTION
Project East Side Baptist Church
Address & Jurisdiction 4045 Commercial, Springfield, OR
Inspector Rick Hernandez
Permit # 811-SPR20 J 0-409
Date 2-16-] J
Inspection Type(s) / Coverage
high strength bolts
o Continuous
~eriodic; frequency
once
Inspections made, including locations
Tcsts pcrformed Tcnsion calibration of high strcngth bolts
Items requiring I) correction, 2) correction of previously listed items, and 3) previously listcd uncorrected itcms
Comments Met on site with erector and general contractor for pre-installation verification of pre-
tensioned high strength bolts using tum-or-the-nut method with match-mat-king. Bolts tested were all
A325 sizes y,," xl '/,', %" x 2", '/,' x 2 V4", and 7/8" x 2 ';"". Three bolts M each size and length were
installed and tightened in a Skidmore-Wilhelm model MZ. All bolts wereltumed 1/3 nominal turn and
all met minimum tension requirements per AISC specifications. Erector Was asked to notify our office
when additional services are needed.
To the best of my knowledge, work inspected above was in accordance with the building department approved
plans, specifications, and applicabl rkmanship provisions oflhe controlling tildi::~:o' CII03A.?
Inspector Sign UTe ID/Certificate Number "-<.Dt"i:> '" ( T"-
Copies to
City of Springfield
Cascade View Constmction I Matt Knights