Loading...
HomeMy WebLinkAboutMiscellaneous Field Test & Inspection Report 2011-2-16 ~~._' ~ Branch Engineering, Inc. Branch Engineering, Inc Project # 09-077 Headquarters 310 5lh Street Springfield, OR 97477 (541) 746 0637 www.branchengineering.com Salem/Keizer Office 4310 Cherry A venueo NE Salem. OR 97303 (503) 779 2577 DAILY REPORT OF STRUCTURAL STEEL AND HIGH STRENGTH BOLT SPECIAL INSPECTION Project East Side Baptist Church Address & Jurisdiction 4045 Commercial, Springfield, OR Inspector Rick Hernandez Permit # 811-SPR20 J 0-409 Date 2-16-] J Inspection Type(s) / Coverage high strength bolts o Continuous ~eriodic; frequency once Inspections made, including locations Tcsts pcrformed Tcnsion calibration of high strcngth bolts Items requiring I) correction, 2) correction of previously listed items, and 3) previously listcd uncorrected itcms Comments Met on site with erector and general contractor for pre-installation verification of pre- tensioned high strength bolts using tum-or-the-nut method with match-mat-king. Bolts tested were all A325 sizes y,," xl '/,', %" x 2", '/,' x 2 V4", and 7/8" x 2 ';"". Three bolts M each size and length were installed and tightened in a Skidmore-Wilhelm model MZ. All bolts wereltumed 1/3 nominal turn and all met minimum tension requirements per AISC specifications. Erector Was asked to notify our office when additional services are needed. To the best of my knowledge, work inspected above was in accordance with the building department approved plans, specifications, and applicabl rkmanship provisions oflhe controlling tildi::~:o' CII03A.? Inspector Sign UTe ID/Certificate Number "-<.Dt"i:> '" ( T"- Copies to City of Springfield Cascade View Constmction I Matt Knights