K S ELECTRIC AND CONSULTANTS
..
Residential - Conunercial - Industrial
KEVIN w. SCHAFEfi
Owner
,...,....n""""(')o....
\.....,"-,OlVOO.,
P.O. Box 24933 Eugene, Oregon 97402 656-6236
.*
..~
,.
City Of Springfield
Building Inspector
225 N. 5th Street
Springfield, Oregon 97477
October 6, i 99j
Atin: llob Barnhart
Rt:[ Ekclrical Inspection of:
The Dan Bi3iwp R.,;:t;~\';II"c
6990 'c' Street
~~I iugiidu, Oregon 97478
Dear [vIr. Barnhart,
I \vas l:ontal:tcd by Dan Bishop to c.\aminc lhe additiun buill unlu his residence al 69~v L
Street in Springlield. I discovered one improper electrical connection in the ailic. This
connection was repaired with the addition of the requilt;U jUIH..:lion be,,,. The remaining t:k\;-
trical wurk June by ivir. Bishop was [ound to have been completed in a satisfactory manor
that meets the eiectrical code requilt:/IIt:/llS.
Feci free 10 \.;uolm.:l HIe if yuu have allY 4uestiulls l:uncerning this situatiulI.
*;",~~): j ,/,"
Kevin 'V. Schar~.. !
K SELECTRIC & CONSULTANTS
t/.
".,'
/
/"
,/ .
Branch
Engineering
..
310 North 5th Street
Springfield. Oregon 97477
1503} 746-0637
FAX (503) 74EHJ389
. January 26,.1996
, Dan Bishop
6990 C Street
,Springtield, OR 97478
. Re: Additional work required to bring building structure into compliance with State of O(egon
One and Two Family Dwelling Specialty Code
As you know, the City of Springfield Building Dept. will accept your building addit!on without
performing inspections, based on an engineer's report whiCh certifies. compliance with the
building code.
After our site inspection, we have determined that, prior to issuance of this report, the
following work must be done:
i.
A beam must be inserted through the gable end ot the addition to support the roof
framing above, and correct an over~span condition. A detail ot this is attached.
./
The rooting over the addition must be up-graded t6- meet Code requirements. We
recommend a single-ply modified bitumen ("torch-down") as supplied by a licensed
roofing contractor, meeting Code requirements for class B rooting.
2.
3. Concrete pier footings must be placed under bearing walls as indicated on the
attached foundation plan.
4. .' Electrical wiring in the attic spaces must be attached at 48" maximum intervals and
supported at 24" 'maximum intervals. ' Electrical service equipment and splice boxes
must have covers attached.
5. .
Plumbing vent pipes must have a positive slope toward the sewer to avoid trapping
condensate or rainwater. .
/
f1f
Please call us when the work is completed, and we will perform, ~r'final inspection and issue
our final inspection report to the City Building Department. If y6u have any questions, please
teel free to call our office. . .