HomeMy WebLinkAboutPermit Correspondence 1996-8-18 Wildwood Plumbing . 383f5 Lower Brice Creek Rd. Culp Creek, Or. 97427 Invoice DATE INVOICE NO. . 8/18/96 1343 BILL TO Dan Bishop 6990 C St. Springfield, Or. 97478 P.O. NO. TERMS PROJECT Net 10 ITEM DESCRIPTION QTY RATE AMOUNT Ma!erial Upgrade waste & vent for bathroom in new 61.97 61.97 addition to meet Oregon Uniform Plumbing Labor Code 6.5 39.00 253.50 Total $315.47 \ , '-- --_.-.._-~-- -- . ... .--.------.------.---------..------ K S ELECTRIC AND CONSULTANTS .. Residential - Conunercial - Industrial KEVIN w. SCHAFEfi Owner ,...,....n""""(')o.... \.....,"-,OlVOO., P.O. Box 24933 Eugene, Oregon 97402 656-6236 .* ..~ ,. City Of Springfield Building Inspector 225 N. 5th Street Springfield, Oregon 97477 October 6, i 99j Atin: llob Barnhart Rt:[ Ekclrical Inspection of: The Dan Bi3iwp R.,;:t;~\';II"c 6990 'c' Street ~~I iugiidu, Oregon 97478 Dear [vIr. Barnhart, I \vas l:ontal:tcd by Dan Bishop to c.\aminc lhe additiun buill unlu his residence al 69~v L Street in Springlield. I discovered one improper electrical connection in the ailic. This connection was repaired with the addition of the requilt;U jUIH..:lion be,,,. The remaining t:k\;- trical wurk June by ivir. Bishop was [ound to have been completed in a satisfactory manor that meets the eiectrical code requilt:/IIt:/llS. Feci free 10 \.;uolm.:l HIe if yuu have allY 4uestiulls l:uncerning this situatiulI. *;",~~): j ,/," Kevin 'V. Schar~.. ! K SELECTRIC & CONSULTANTS t/. ".,' / /" ,/ . Branch Engineering .. 310 North 5th Street Springfield. Oregon 97477 1503} 746-0637 FAX (503) 74EHJ389 . January 26,.1996 , Dan Bishop 6990 C Street ,Springtield, OR 97478 . Re: Additional work required to bring building structure into compliance with State of O(egon One and Two Family Dwelling Specialty Code As you know, the City of Springfield Building Dept. will accept your building addit!on without performing inspections, based on an engineer's report whiCh certifies. compliance with the building code. After our site inspection, we have determined that, prior to issuance of this report, the following work must be done: i. A beam must be inserted through the gable end ot the addition to support the roof framing above, and correct an over~span condition. A detail ot this is attached. ./ The rooting over the addition must be up-graded t6- meet Code requirements. We recommend a single-ply modified bitumen ("torch-down") as supplied by a licensed roofing contractor, meeting Code requirements for class B rooting. 2. 3. Concrete pier footings must be placed under bearing walls as indicated on the attached foundation plan. 4. .' Electrical wiring in the attic spaces must be attached at 48" maximum intervals and supported at 24" 'maximum intervals. ' Electrical service equipment and splice boxes must have covers attached. 5. . Plumbing vent pipes must have a positive slope toward the sewer to avoid trapping condensate or rainwater. . / f1f Please call us when the work is completed, and we will perform, ~r'final inspection and issue our final inspection report to the City Building Department. If y6u have any questions, please teel free to call our office. . . i . ~. " TRANSPORTATION CIVIL' SURVEYING \. . ""-' -..., "'; ~. , ";. ~) j!