HomeMy WebLinkAboutCorrespondence PLANNER 6/25/2009 (2)
.
.
HOPKINS Steve
From:
Sent:
To:
Subject:
MCEACHERN Clayton
Thursday, June 25, 2009 11 :35 AM
HOPKINS Steve
fire station at jasper
The actual station site is not in city limits (as you are probably aware) but there is adequate sanitary sewers on two sides
of the site so service shouldn't be a problem. The site does slope at 7% to the north which might have some design
challenges for something like a firestation (but certainly not a deal breaker). There are no improvement agreements on
the property currently. Soil is 73-linslaw loam. Somewhat poor drainage with a water table at 2' or so by the lane
county soil survey. Infiltration schemes to take care of stormwater may not work well here (although they may also
work jf done right or local conditions or different from soil survey). I realize this is probably way more than you need.
Clayton McEachern, PE
Civil Engineer
City of Springfield, Engineering Division
Ph (541) 736-1036
Fax (541) 736-1021
cmceachern@ci.sprinafield.or.us